1.
J Chromatogr A ; 849(1): 175-89, 1999 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-10444842

RESUMO

Peptides and proteins were separated by capillary electrophoresis (CE) in fused-silica capillaries coated with an irreversibly adsorbed monolayer of derivatized polystyrene nanoparticles. Whereas phosphate buffer, pH 3.10, enabled the highly efficient separation of basic proteins with plate counts up to 1,400,000 m-1, volatile buffer components such as formic acid or acetic acid titrated with ammonia to the desired pH had to be used for the direct coupling of CE with electrospray ionization mass spectrometry (ESI-MS). Compared to 40 mM phosphoric acid-sodium hydroxide, pH 3.10, a background electrolyte containing 125 mM formic acid-ammonia, pH 4.00, was shown to yield equivalent separation efficiency. Investigation of the influence of buffered electrolytes on the ESI-MS signal of lysozyme at pH 2.70-4.00 showed that the charge state distribution shifted to lower charge states at higher pH with a concomitant five-fold decrease in signal intensity of the most abundant signal. The presence of trifluoroacetic acid in the background electrolyte greatly increased the level of baseline noise and completely inhibited the observation of any mass signals related to proteins. Full scan spectra could be acquired from 50-500 fmol amounts of proteins during coupled CE-ESI-MS utilizing 100-125 mM formic acid-ammonia, pH 3.10. However, compared to UV detection, considerable band broadening is observed with ESI-MS detection which is mainly attributed to column overloading, band spreading in the interface, and scanning data acquisition. Finally, the major whey proteins beta-lactoglobulin A, beta-lactoglobulin B, and alpha-lactalbumin were identified in a whey drink by comparison of molecular masses determined by CE-ESI-MS to molecular masses calculated from the amino acid sequence.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar/métodos , Espectrometria de Massas/métodos , Proteínas/química , Eletrólitos/química , Estudos de Avaliação como Assunto , Concentração de Íons de Hidrogênio , Espectrofotometria Ultravioleta , Volatilização
2.
Electrophoresis ; 19(2): 262-9, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9548289

RESUMO

High-resolution capillary electrophoretic separation of proteins and peptides was achieved by coating the inner wall of 75 microm ID fused-silica capillaries with 40-140 nm polystyrene particles which have been derivatized with alpha-omega-diamines such as ethylenediamine or 1,10-diaminodecane. A stable and irreversibly adsorbed coating was obtained upon deprotonation of the capillary surface with aqueous sodium hydroxide and subsequent flushing with a suspension of the positively charged particles. At pH 3.1, the detrimental adsorption of proteins to the capillary inner wall was suppressed efficiently because of electrostatic repulsion of the positively charged proteins from the positively charged coating which enabled protein separations with maximum efficiencies of 400000 plates per meter. A substantial improvement of separation efficiency in particle-coated capillaries was observed after in-column derivatization of amino functionalities with 2,3-epoxy-l-propanol, resulting in a more hydrophilic coating. Five basic and four acidic proteins could be separated in less than 7 min with efficiencies up to 1900000 theoretical plates per meter. Finally, coated capillaries were applied to the high-resolution analysis of protein glycoforms and bioactive peptides.


Assuntos
Eletroforese Capilar/métodos , Peptídeos/análise , Poliestirenos , Proteínas/análise , Dióxido de Silício , Animais , Bovinos , Galinhas , Etilenodiaminas , Cavalos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS