Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesthesia ; 77(7): 751-762, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35302235

RESUMO

Although patient safety related to airway management has improved substantially over the last few decades, life-threatening events still occur. Technical skills, clinical expertise and human factors contribute to successful airway management. Checklists aim to improve safety by providing a structured approach to equipment, personnel and decision-making. This audit investigates adherence to our institution's airway checklist from 1 June 2016 to 31 May 2021. Inclusion criteria were procedures requiring airway management and we excluded all procedures performed solely under regional anaesthesia, sedation without airway management or paediatric and cardiovascular surgery. The primary outcome was the proportion of wholly performed pre-induction checklists. Secondary outcomes were the pattern of adherence over the 5 years well as details of airway management, including: airway management difficulties; time and location of induction; anaesthesia teams in operating theatres (including teams for different surgical specialities); non-operating theatre and emergency procedures; type of anaesthesia (general or combined); and urgency of the procedure. In total, 95,946 procedures were included. In 57.3%, anaesthesia pre-induction checklists were completed. Over the 5 years after implementation, adherence improved from 48.3% to 66.7% (p < 0.001). Anticipated and unanticipated airway management difficulties (e.g. facemask ventilation, supraglottic airway device or intubation) defined by the handling anaesthetist were encountered in 4.2% of all procedures. Completion of the checklist differed depending on the time of day (61.3% during the day vs. 35.0% during the night, p < 0.001). Completion also differed depending on location (66.8% in operating theatres vs. 41.0% for non-operating theatre anaesthesia, p < 0.001) and urgency of procedure (65.4% in non-emergencies vs. 35.4% in emergencies, p < 0.001). A mixed-effect model indicated that urgency of procedure is a strong predictor for adherence, with emergency cases having lower adherence (OR 0.58, 95%CI 0.49-0.68, p < 0.001). In conclusion, over 5 years, a significant increase in adherence to an anaesthesia pre-induction checklist was found, and areas for further improvement (e.g. emergencies, non-operating room procedures, night-time procedures) were identified.


Assuntos
Lista de Checagem , Emergências , Manuseio das Vias Aéreas/métodos , Anestesia Geral , Criança , Humanos , Salas Cirúrgicas
4.
Br J Anaesth ; 120(3): 592-599, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29452816

RESUMO

BACKGROUND: Transnasal humidified rapid insufflation ventilatory exchange (THRIVE) comprises the administration of heated, humidified, and blended air/oxygen mixtures via nasal cannula at rates of ≥2 litres kg-1 min-1. The aim of this randomized controlled study was to evaluate the length of the safe apnoea time using THRIVE with two different oxygen concentrations (100% vs 30% oxygen) compared with standard low-flow 100% oxygen administration. METHODS: Sixty patients, aged 1-6 yr, weighing 10-20 kg, undergoing general anaesthesia for elective surgery, were randomly allocated to receive one of the following oxygen administration methods during apnoea: 1) low-flow 100% oxygen at 0.2 litres kg-1 min-1; 2) THRIVE 100% oxygen at 2 litres kg-1 min-1; and 3) THRIVE 30% oxygen at 2 litres kg-1 min-1. Primary outcome was time to desaturation to 95%. Termination criteria included SpO2 decreased to 95%, transcutaneous CO2 increased to 65 mmHg, or apnoea time of 10 min. RESULTS: The median (interquartile range) [range] apnoea time was 6.9 (5.7-7.8) [2.8-10.0] min for low-flow 100% oxygen, 7.6 (6.2-9.1) [5.2-10.0] min for THRIVE 100% oxygen, and 3.0 (2.4-3.7) [0.2-5.3] min for THRIVE 30% oxygen. No significant difference was detected between apnoea times with low-flow and THRIVE 100% oxygen administration (P=0.15). THRIVE with 30% oxygen demonstrated significantly shorter apnoea times (P<0.001) than both 100% oxygen modalities. The overall rate of transcutaneous CO2 increase was 0.57 (0.49-0.63) [0.29-8.92] kPa min-1 without differences between the 3 groups (P=0.25). CONCLUSIONS: High-flow 100% oxygen (2 litres kg-1 min-1) administered via nasal cannulas did not extend the safe apnoea time for children weighing 10-20 kg compared with low-flow nasal cannula oxygen (0.2 litres kg-1 min-1). No ventilatory effect was observed with THRIVE at 2.0 litres kg-1 min-1. CLINICAL TRIAL REGISTRATION: NCT02979067.


Assuntos
Apneia/terapia , Insuflação/métodos , Oxigenoterapia/métodos , Administração Intranasal , Criança , Pré-Escolar , Feminino , Humanos , Umidificadores , Lactente , Masculino , Estudos Prospectivos , Resultado do Tratamento
5.
Anaesthesia ; 72(3): 370-378, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27882535

RESUMO

This prospective randomised, controlled trial compares the performance of three unchannelled videolaryngoscopes (KingVision™ , Airtraq™ , A.P. Advance™ MAC) and the standard Macintosh laryngoscope. With ethics committee approval and written informed consent, 480 patients were included. A difficult airway was created with a cervical collar, limiting mouth opening and neck movement. Primary outcome was first-attempt orotracheal intubation success. Overall success, laryngeal view, intubation difficulty scale, handling, intubation times and side-effects were secondary outcomes. First-attempt success rates were: KingVision 90% (95% CI 83-94%), Airtraq 82% (74-88%), A.P. Advance MAC 49% (40-58%), Macintosh 44% (35-53%; p < 0.001). The 95% confidence interval of first-attempt success rate was thus below 90% for all devices, but the KingVision and the Airtraq performed better than the A.P. Advance MAC and the Macintosh laryngoscope. Also, performance was better with the KingVision and the Airtraq in terms of overall success, laryngeal view, intubation difficulty scale and quality of view. Problems with tube advancement were a frequent cause of intubation failure. In summary, the KingVision and the Airtraq performed better than the A.P. Advance MAC and the Macintosh laryngoscope. Success rates of the unchannelled KingVision and Airtraq were similar to those of their channelled versions reported previously, indicating that performance largely depends on blade design rather than the presence of a channel for tube advancement.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Laringoscópios/efeitos adversos , Laringoscopia/efeitos adversos , Laringoscopia/instrumentação , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Gravação em Vídeo/instrumentação
6.
Anaesthesia ; 71(12): 1456-1463, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27670928

RESUMO

We compared the Bonfils™ and SensaScope™ rigid fibreoptic scopes in 200 patients with a simulated difficult airway randomised to one of the two devices. A cervical collar inhibited neck movement and reduced mouth opening to a mean (SD) of 23 (3) mm. The primary outcome parameter was overall success of tracheal intubation; secondary outcomes included first-attempt success, intubation times, difficulty of intubation, fibreoptic view and side-effects. The mean (95% CI) overall success rate was 88 (80-94)% for the Bonfils and 89 (81-94)% for the SensaScope (p = 0.83). First-attempt intubation success rates were 63 (53-72)% for the Bonfils and 72 (62-81)% for the SensaScope (p = 0.17). Median (IQR [range]) intubation time was significantly shorter with the SensaScope (34 (20-84 [5-240]) s vs. 45 (25-134 [12-230]) s), and fibreoptic view was significantly better with the SensaScope (full view of the glottis in 79% with the SensaScope vs. 61% with the Bonfils). This might be explained by its steerable tip and the S-formed shape, contributing to better manoeuvrability. There were no differences in the difficulty of intubation or side-effects.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Adulto , Idoso , Feminino , Tecnologia de Fibra Óptica , Humanos , Intubação Intratraqueal/efeitos adversos , Laringoscópios/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Br J Anaesth ; 116(5): 670-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27106971

RESUMO

BACKGROUND: Videolaryngoscopes are aggressively marketed, but independent evaluation in difficult airways is scarce. This multicentre, prospective randomized controlled trial evaluates six videolaryngoscopes in patients with a simulated difficult airway. METHODS: With ethics committee approval and written informed consent, 12 senior anaesthetists intubated the trachea of 720 patients. A cervical collar limited mouth opening and neck movement, making intubation difficult. We evaluated three unchannelled (C-MAC™ D-blade, GlideScope™, and McGrath™) and three channelled videolaryngoscopes (Airtraq™, A.P. Advance™ difficult airway blade, and KingVision™). The primary outcome was first-attempt intubation success rate. Secondary outcomes included overall success rate, laryngeal view, intubation times, and side-effects. The primary hypothesis for every videolaryngoscope was that the 95% confidence interval of first-attempt success rate is ≥90%. RESULTS: Mouth opening was decreased from 46 (sd 7) to 23 (3) mm with the cervical collar. First-attempt success rates were 98% (McGrath™), 95% (C-MAC™ D-blade), 87% (KingVision™), 85% (GlideScope™ and Airtraq™), and 37% (A.P. Advance™, P<0.01). The 95% confidence interval of first-attempt success rate was >90% only for the McGrath™. Overall success, laryngeal view, and intubation times differed significantly between videolaryngoscopes (all P<0.01). Side-effects were minor. CONCLUSIONS: This trial revealed differences in the performance of six videolaryngoscopes in 720 patients with restricted neck movement and limited mouth opening. In this setting, first-attempt success rates were 85-98%, except for the A.P. Advance™ difficult airway blade. Highest success and lowest tissue trauma rates were achieved by the McGrath™ and C-MAC™ D-blade, highlighting the importance of the videolaryngoscope blade design. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: identifier NCT01692535.


Assuntos
Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/métodos , Método Duplo-Cego , Desenho de Equipamento , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Laringoscópios/efeitos adversos , Laringoscopia/efeitos adversos , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Gravação em Vídeo , Adulto Jovem
10.
Br J Anaesth ; 109(6): 990-5, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22956643

RESUMO

BACKGROUND: The i-gel™ supraglottic airway device has been studied in randomized controlled studies, but it has not been evaluated in a large prospective patient cohort. Therefore, we performed this prospective multicentre observational study to evaluate success rates, airway leak pressure, risk factors for i-gel failure, and adverse events. METHODS: With Ethics Committee approval and waiver of patients' consent, data about anaesthesia providers, patient characteristics, and the performance of the i-gel were recorded in five independent hospitals in Switzerland over a period of 24 months. We analysed success rates, leak pressures, adverse events, and risk factors for failure. RESULTS: Data from 2049 i-gel uses were analysed. Patients' mean age was 47 (range 6-91) yr. The primary i-gel success rate without changing size was 93%; the overall success rate was 96%. Insertion was deemed very easy or easy in 92%. The mean airway leak pressure was 26 (8) cm H(2)O. The mean anaesthesia time was 67 (42) min. Risk factors associated with i-gel failure were males (P<0.001), impaired mandibular subluxation (P=0.01), poor dentition (P=0.02), and older age (P<0.01). Adverse events recorded were laryngeal spasms (n=25, 1.2%), blood stained airway devices (n=79, 3.9%), transient nerve damage (n=2, 0.1%), one case of transient vasovagal asystole, and one glottic haematoma. CONCLUSIONS: The i-gel is a reliable supraglottic airway device failing in <5% and providing high airway leak pressures. Males, impaired mandibular subluxation, poor dentition, and older age are risk factors associated with primary device failure. Serious adverse events are rare.


Assuntos
Intubação Intratraqueal/instrumentação , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Equipamentos Descartáveis , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Fatores Sexuais , Suíça , Adulto Jovem
11.
Minerva Anestesiol ; 78(5): 550-5, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22310191

RESUMO

BACKGROUND: Intraoperative major bleeding is a common complication during surgery and can lead to the transfusion of blood products and/or procoagulant drugs. This is a therapeutic challenge, and adherence to guidelines is desirable to preserve blood product resources. The intraoperative administration of fibrinogen concentrate, a pro-coagulant drug, in bleeding patients might reduce the use and therefore the risks associated with blood products. METHODS: In this observational pilot study we determined whether fibrinogen measured by point-of-care thromboelastometry (Rotem®, fibtem-test) would lead to a similar therapeutical decision concerning the administration of fibrinogen concentrate when compared to the standard method (Clauss). RESULTS: Blood samples of 36 patients undergoing major surgery were simultaneously analyzed using both methods. According to the cutoff values of current guidelines based on the standard method, no patient would receive fibrinogen concentrate. In comparison, if point-of-care thromboelastometry were used and its cutoff for fibrinogen applied, 16 patients (44%, P<0.001) would receive fibrinogen concentrate. CONCLUSION: The method used for intraoperative coagulation monitoring has a major impact on therapeutic decisions concerning the use of blood products and/or pro-coagulant drugs. If fibrinogen was measured by point-of-care thromboelastometry instead of the standard method according to Clauss, the use of fibrinogen concentrate would increase significantly and less fresh frozen plasma would be administered.


Assuntos
Fibrinogênio/análise , Fibrinogênio/uso terapêutico , Monitorização Intraoperatória , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Testes de Coagulação Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
12.
Br J Anaesth ; 107(2): 243-50, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21652615

RESUMO

BACKGROUND: The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™). METHODS: With ethics committee approval and written informed consent, 80 patients with predictors of a difficult airway were computer randomized to either supraglottic airway device (SAD). The corresponding tracheal tube (TT) was introduced through the SAD under fibreoptic visualization but without fibreoptic guidance. Primary outcome was blind intubation success rate. Times, airway leak pressure, fibreoptic view, and adverse events were recorded. To control for the influence of the TT, we compared data from 40 patients described in an accompanying study (sILMA™ with Magill TT and i-gel™ with sILMA™ TT). RESULTS: Blind intubation success rate through the sILMA™ (69%) was higher than with the i-gel™ (15%, P<0.001). Data from the other patient group excluded the TT type as the primary cause for the difference in success rate. Removal of SADs was without problems with no difference between the type of SAD. CONCLUSIONS: Blind tracheal intubation using the sILMA™ tube through the sILMA™ is much more successful than blind intubation with a Magill PVC tube through the i-gel™. Because of its low success rate, we would not recommend blind intubation through the i-gel™.


Assuntos
Intubação Intratraqueal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/métodos , Remoção de Dispositivo , Equipamentos Descartáveis , Desenho de Equipamento , Feminino , Tecnologia de Fibra Óptica/métodos , Hemodinâmica , Humanos , Intubação Intratraqueal/efeitos adversos , Máscaras Laríngeas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Faringite/etiologia , Complicações Pós-Operatórias , Estudos Prospectivos , Adulto Jovem
13.
Br J Anaesth ; 107(2): 251-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21652616

RESUMO

BACKGROUND: The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway. METHODS: With ethics committee approval and written informed consent, 160 patients were randomly assigned to either SAD. After placement of the SAD, a fibreoptic bronchoscope was introduced into the trachea as a railroad for the TT. Primary outcome variable was the first-attempt fibreoptic-guided intubation success rate. Secondary variables included time for insertion and intubation, airway leak pressures, fibreoptic view, and adverse events. Data are presented as mean (sd) or percentages. A P-value of < 0.05 was considered statistically significant. RESULTS: Fibreoptic-guided intubation was successful at the first attempt in 76 patients (96%) using the i-gel™ and in 71 patients (90%) using the sILMA™ (P=0.21). Most of the failed intubations were rescued by conventional laryngoscopy. Airway leak pressure was higher for the sILMA™. There were no problems during removal of either type of SAD. CONCLUSIONS: Fibreopic-guided tracheal intubation through the i-gel™ using a standard Rüsch™ Magill TT is successful and an alternative to the sILMA™ with the sILMA™ TT.


Assuntos
Tecnologia de Fibra Óptica/métodos , Intubação Intratraqueal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/métodos , Remoção de Dispositivo , Equipamentos Descartáveis , Desenho de Equipamento , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Máscaras Laríngeas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Faringite/etiologia , Complicações Pós-Operatórias , Estudos Prospectivos , Método Simples-Cego , Adulto Jovem
14.
Br J Anaesth ; 106(5): 738-42, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21414983

RESUMO

BACKGROUND: Ultrasound-guided techniques are increasingly used in anaesthetic practice to identify tissues beneath the skin and to increase the accuracy of placement of needles close to targeted structures. To examine ultrasound's usefulness for dilatational tracheostomy, we performed ultrasound-guided tracheal punctures in human cadavers followed by computer-tomographic (CT) control. METHODS: The trachea of nine cadavers was punctured using an in-plane approach with a longitudinal ultrasound visualization of the trachea. As soon as a loss of resistance was felt, or air/fluid could be aspirated into the attached syringe, the syringe was disconnected and the ultrasound transducer set aside. Thereafter, a cricothyroidotomy guidewire was inserted through the needle into the trachea. The needle was then removed, leaving the wire in place and a control CT imaging of the neck and the chest was performed. Primary outcome was successful wire insertion into the trachea. RESULTS: Tracheal puncture and wire insertion was successful in eight of nine cadavers at the first attempt and in one at the second attempt (total of 10 puncture attempts, nine successful). In eight of nine successfully inserted wires, the wire was placed on the defined midline. CONCLUSIONS: Ultrasound guidance can facilitate successful tracheal puncture. However, combining an in-plane approach with a longitudinal ultrasound visualization of the trachea neither guarantees an exact midline puncture nor allows detection of a misplaced guidewire.


Assuntos
Traqueia/diagnóstico por imagem , Traqueostomia/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Traqueia/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS