Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Phys Rev Lett ; 101(11): 117003, 2008 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-18851318

RESUMO

Macroscopic resonant tunneling between the two lowest lying states of a bistable rf SQUID is used to characterize noise in a flux qubit. Measurements of the incoherent decay rate as a function of flux bias revealed a Gaussian-shaped profile that is not peaked at the resonance point but is shifted to a bias at which the initial well is higher than the target well. The rms amplitude of the noise, which is proportional to the dephasing rate 1/tauphi, was observed to be weakly dependent on temperature below 70 mK. Analysis of these results indicates that the dominant source of low energy flux noise in this device is a quantum mechanical environment in thermal equilibrium.

2.
Eur J Anaesthesiol ; 22(8): 630-3, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16119601

RESUMO

BACKGROUND AND OBJECTIVE: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal laryngeal mask airway during pressure support ventilation. METHODS: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 2%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH2O, and pressure support set 5 cmH2O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH2O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, airway occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. RESULTS: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). CONCLUSION: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal laryngeal mask airway. However, these differences are small and of doubtful clinical importance.


Assuntos
Anestesia Geral , Anestésicos Inalatórios , Anestésicos Intravenosos , Isoflurano , Máscaras Laríngeas , Éteres Metílicos , Propofol , Respiração Artificial , Adulto , Idoso , Período de Recuperação da Anestesia , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Musculoesquelético/cirurgia , Mecânica Respiratória/efeitos dos fármacos , Sevoflurano
3.
Am J Physiol Heart Circ Physiol ; 289(1): H168-73, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15764677

RESUMO

We investigated intestinal oxygen supply and mucosal tissue PO2 during administration of increasing dosages of continuously infused arginine vasopressin (AVP) in an autoperfused, innervated jejunal segments in anesthetized pigs. Mucosal tissue PO2 was measured by employing two Clark-type surface oxygen electrodes. Oxygen saturation of jejunal microvascular hemoglobin was determined by tissue reflectance spectrophotometry. Microvascular blood flow was assessed by laser-Doppler velocimetry. Systemic hemodynamic variables, mesenteric venous and systemic acid-base and blood gas variables, and lactate measurements were recorded. Measurements were performed at baseline and at 20-min intervals during incremental AVP infusion (n = 8; 0.007, 0.014, 0.029, 0.057, 0.114, and 0.229 IU.kg(-1).h(-1), respectively) or infusion of saline (n=8). AVP infusion led to a significant (P < .05), dose-dependent decrease in cardiac index (from 121 +/- 31 to 77 +/- 27 ml.kg(-1).min(-1) at 0.229 IU.kg(-1).h(-1)) and systemic oxygen delivery (from 14 +/- 3 to 9 +/- 3 ml.kg(-1).min(-1) at 0.229 IU.kg(-1).h(-1)) concomitant with an increase in systemic oxygen extraction ratio (from 31 +/- 4 to 48 +/- 10%). AVP decreased microvascular blood flow (from 133 +/- 47 to 82 +/- 35 perfusion units at 0.114 IU.kg(-1).h(-1)), mucosal tissue PO2 (from 26 +/- 7 to 7 +/- 2 mmHg at 0.229 IU.kg(-1).h(-1)), and microvascular hemoglobin oxygen saturation (from 51 +/- 9 to 26 +/- 12% at 0.229 IU.kg(-1).h(-1)) without a significant increase in mesenteric venous lactate concentration (2.3 +/- 0.8 vs. 3.4 +/- 0.7 mmol/l). We conclude that continuously infused AVP decreases intestinal oxygen supply and mucosal tissue PO2 due to a reduction in microvascular blood flow and due to the special vascular supply in the jejunal mucosa in a dose-dependent manner in pigs.


Assuntos
Arginina Vasopressina/farmacologia , Mucosa Intestinal/metabolismo , Jejuno/irrigação sanguínea , Oxigênio/metabolismo , Vasoconstritores/farmacologia , Animais , Arginina Vasopressina/administração & dosagem , Disponibilidade Biológica , Débito Cardíaco/efeitos dos fármacos , Relação Dose-Resposta a Droga , Bombas de Infusão , Microcirculação/efeitos dos fármacos , Oxigênio/sangue , Oxiemoglobinas/metabolismo , Pressão Parcial , Suínos , Vasoconstritores/administração & dosagem
4.
Anesth Analg ; 100(2): 357-360, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15673856

RESUMO

Continuous positive airway pressure (CPAP) and pressure support ventilation (PSV) improve gas exchange in adults, but there are little published data regarding children. We compared the efficacy of PSV with CPAP in anesthetized children managed with the ProSeal laryngeal mask airway. Patients were randomized into two equal-sized crossover groups and data were collected before surgery. In Group 1, patients underwent CPAP, PSV, and CPAP in sequence. In Group 2, patients underwent PSV, CPAP, and PSV in sequence. PSV comprised positive end-expiratory pressure set at 3 cm H(2)O and inspiratory pressure support set at 10 cm H(2)O above positive end-expiratory pressure. CPAP was set at 3 cm H(2)O. Each ventilatory mode was maintained for 5 min. The following data were recorded at each ventilatory mode: ETco(2), Spo(2), expired tidal volume, peak airway pressure, work of breathing patient (WOB), delta esophageal pressure, pressure time product, respiratory drive, inspiratory time fraction, respiratory rate, noninvasive mean arterial blood pressure, and heart rate. In Group 1, measurements for CPAP were similar before and after PSV. In Group 2, measurements for PSV were similar before and after CPAP. When compared with CPAP, PSV had lower ETco(2) (46 +/- 6 versus 52 +/- 7 mm Hg; P < 0.001), slower respiratory rate (24 +/- 6 versus 30 +/- 6 min(-1); P < 0.001), lower WOB (0.54 +/- 0.54 versus 0.95 +/- 0.72 JL(-1); P < 0.05), lower pressure time product (94 +/- 88 versus 150 +/- 90 cm H(2)O s(-1)min(-1); P < 0.001), lower delta esophageal pressure (10.6 +/- 7.4 versus 14.1 +/- 8.9 cm H(2)O; P < 0.05), lower inspiratory time fraction (29% +/- 3% versus 34% +/- 5%; P < 0.001), and higher expired tidal volume (179 +/- 50 versus 129 +/- 44 mL; P < 0.001). There were no differences in Spo(2), respiratory drive, mean arterial blood pressure, and heart rate. We conclude that PSV improves gas exchange and reduces WOB during ProSeal laryngeal mask airway anesthesia compared with CPAP in ASA physical status I children aged 1-7 yr.


Assuntos
Anestesia por Inalação , Máscaras Laríngeas , Respiração Artificial/métodos , Criança , Pré-Escolar , Estudos Cross-Over , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Lactente , Masculino , Monitorização Intraoperatória , Testes de Função Respiratória , Tamanho da Amostra
5.
Eur Surg Res ; 37(6): 365-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16465062

RESUMO

BACKGROUND: Extended hepatectomy is a valid model for the study of acute liver failure. Since the porcine liver is comparable in size, morphology and anatomy to the human liver, we describe a technique employing hepatic ischemia and extended liver resection to induce acute liver failure in a porcine model as a means of studying bioartificial liver support. METHOD: A subtotal (75-80% resection) extended left hepatectomy was performed in 7 pigs after 60 min warm ischemia of the future remnant liver. After resection, the animals were given the best supportive care and observed until death. RESULTS: All animals died within 18-48 h, none as a result of surgical complications. Gross appearance of the liver showed severe steatosis of the right lateral lobe, and histology revealed severe coagulative necrosis of the whole lobule. CONCLUSION: This technique of extended liver resection after hepatic ischemia in the porcine model may be useful for studies of potentially reversible acute liver failure and experimental bioartificial support.


Assuntos
Falência Hepática Aguda/etiologia , Falência Hepática Aguda/terapia , Fígado Artificial , Animais , Aspartato Aminotransferases/sangue , Bilirrubina/sangue , Modelos Animais de Doenças , Hepatectomia , Humanos , Isquemia/sangue , Isquemia/complicações , Isquemia/patologia , Fígado/irrigação sanguínea , Fígado/patologia , Falência Hepática Aguda/sangue , Falência Hepática Aguda/patologia , Tempo de Protrombina , Especificidade da Espécie , Sus scrofa
6.
Anaesth Intensive Care ; 32(6): 804-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15648991

RESUMO

We compared positive pressure ventilation with pressure support ventilation at different levels of positive end expiratory pressure (PEEP) using the ProSeal laryngeal mask airway (PLMA). Forty-two anaesthetized adults (ASA 1-2, aged 19 to 63 years) underwent positive pressure ventilation and then pressure support ventilation each with PEEP set at 0, 5 and 10 cmH2O in random order. Pressure support ventilation was with the inspired tidal volume (VTInsp) set at 7 ml/kg and the respiratory rate adjusted to maintain the end-tidal CO2 (ETCO2) at 40 mmHg. Pressure support ventilation was with pressure support set at 5 cmH2O above PEEP and initiated when inspiration produced a 2 cmH2O reduction in airway pressure. Tidal volumes were similar during positive pressure and pressure support ventilation with PEEP, but were higher for the former without PEEP Respiratory rate and peak inspiratory flow rate were higher during pressure support than positive pressure ventilation (all P < 0.001). Peak airway pressure (Ppaw), mean airway pressure (Mpaw), peak expiratory flow rate, and expired airway resistance were lower during pressure support than positive pressure ventilation (all P < 0.001). With PEEP set at 10 cmH2O, ETCO2 was lower for pressure support than positive pressure ventilation. During positive pressure ventilation, there was an increase in Ppaw, Mpaw and dynamic compliance (Cdyn) with increasing levels of PEEP (all P < 0.01). During pressure support ventilation, there was an increase in inspired and expired tidal volume, Ppaw, peak inspiratory and expiratory flow rates and Cdyn, and a reduction in ETCO2, work of breathing, and expired airway resistance with increasing levels of PEEP (all P < 0.01). There were no differences in SpO2, non-invasive mean arterial pressure, heart rate or leak fraction. We conclude that pressure support ventilation provides equally effective gas exchange as positive pressure ventilation during PLMA anaesthesia with or without PEEP at the tested settings. During pressure support, PEEP increases ventilation and reduces work on breathing without increasing leak fraction.


Assuntos
Máscaras Laríngeas , Doenças Musculoesqueléticas/cirurgia , Respiração com Pressão Positiva , Adulto , Análise de Variância , Gasometria , Estudos de Coortes , Feminino , Seguimentos , Humanos , Ventilação com Pressão Positiva Intermitente/métodos , Masculino , Pessoa de Meia-Idade , Doenças Musculoesqueléticas/diagnóstico , Procedimentos Ortopédicos/métodos , Probabilidade , Estudos Prospectivos , Troca Gasosa Pulmonar , Respiração Artificial/métodos , Medição de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-12759874

RESUMO

We tested the hypothesis that mucosal pressures are higher for the laryngeal tube airway trade mark than the ProSeal laryngeal mask airway. Fifteen fresh cadavers were studied. Microchip pressure sensors were attached to the laryngeal tube airway and ProSeal laryngeal mask airway at four similar anatomical locations (base of tongue, lateral pharynx, posterior pharynx and posterior hypopharynx) and three dissimilar locations (laryngeal tube airway trade mark, anterior and lateral hypopharynx; ProSeal laryngeal mask airway, pyriform fossa). The cuff volume (laryngeal tube airway, < or = 140 ml; ProSeal laryngeal mask airway, < or = 30 ml) was adjusted until the oropharyngeal leak pressure was 15 cm H2O and the mucosal pressures recorded. This was repeated at an oropharyngeal leak pressure of 20, 25 and 30 cm H2O. Mucosal pressures in the lateral pharynx were always similar. Mucosal pressures at the base of tongue and posterior pharynx were similar for the laryngeal tube airway and ProSeal laryngeal mask airway at 15 and 20 cm H2O, but were higher for the laryngeal tube airway at 25 cm H2O at 30 cm H2O. Mucosal pressures in the posterior hypopharynx were always higher for the laryngeal tube airway (all: p < 0.03). Mean mucosal pressures for the laryngeal tube airway ranged from 8-31, 2-13 and 15-41 cm H2O for the base of tongue, lateral pharynx and posterior pharynx (proximal cuff) respectively and 3-7, 3-7 and 7-18 cm H2O for the anterior, lateral and posterior hypopharynx (distal cuff) respectively. Mean mucosal pressures for the ProSeal laryngeal mask airway ranged from 6-23, 3-10, 8-25, 6-17 and 2-8 cm H2O for the base of tongue, lateral pharynx, posterior pharynx, pyriform fossa and posterior hypopharynx respectively. We conclude that mucosal pressures are higher for the laryngeal tube airway, particularly when oropharyngeal leak pressure greater than 25 cm H2O. This suggests that mucosal ischemic injury will be more common with the LTA than the PLMA.


Assuntos
Máscaras Laríngeas , Faringe/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Mucosa Laríngea/fisiologia , Masculino , Pessoa de Meia-Idade , Orofaringe/fisiologia , Pressão
9.
Eur J Anaesthesiol ; 19(6): 424-7, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12094916

RESUMO

BACKGROUND AND OBJECTIVE: Ventilation of the lungs with positive end-expiratory pressure during pneumoperitoneum has been shown to improve the arterial partial pressure of oxygen. The implications of spontaneous breathing on pulmonary gas exchange remain unknown in this setting. We therefore sought to examine the influence of pressure-support ventilation with spontaneous breathing on gas exchange during simulated laparoscopy. METHODS: Ten pigs were subjected to pneumoperitoneum at a pressure of 15 cmH2O. Animals received, in a random order, pressure-support and pressure-controlled ventilation for 60 min per mode. Inert gas and haemodynamic measurements were performed before changing to a subsequent mode. RESULTS: Pressure-support ventilation was more efficient than pressure-controlled ventilation regarding perfusion of normal V(A)/Q lung areas (78 +/- 4% vs. 72 +/- 5%) (P < 0.05), alveolar-arterial partial pressure of oxygen difference (9.73 +/- 1.3 vs. 11.2 +/- 1.2 kPa) and arterial partial pressure of oxygen (14.93 +/- 1.6 vs. 13.7 +/- 2.0 kPa) (P < 0.05). CONCLUSIONS: Pressure-support ventilation resulted in significantly better gas exchange than pressure-controlled ventilation in this model of simulated laparoscopy.


Assuntos
Pneumoperitônio Artificial , Respiração com Pressão Positiva/métodos , Troca Gasosa Pulmonar , Relação Ventilação-Perfusão , Animais , Laparoscopia , Modelos Animais , Testes de Função Respiratória , Mecânica Respiratória/fisiologia , Suínos
10.
Anesthesiology ; 95(6): 1422-6, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11748401

RESUMO

BACKGROUND: Decreased arterial partial pressure of oxygen (PaO2) during volatile anesthesia is well-known. Halothane has been examined with the multiple inert gas elimination technique and has been shown to alter the distribution of pulmonary blood flow and thus PaO2. The effects of isoflurane and sevoflurane on pulmonary gas exchange remain unknown. The authors hypothesized that sevoflurane with a relatively high minimum alveolar concentration (MAC) would result in significantly more gas exchange disturbances in comparison with isoflurane or control. METHODS: This study was performed in a porcine model with an air pneumoperitoneum that generates a reproducible gas exchange defect. After a baseline measurement of pulmonary gas exchange (multiple inert gas elimination technique) during propofol anesthesia, 21 pigs were randomly assigned to three groups of seven animals each. One group received isoflurane anesthesia, one group received sevoflurane anesthesia, and one group was continued on propofol anesthesia (control). After 30 min of volatile anesthesia at 1 MAC or propofol anesthesia, a second measurement (multiple inert gas elimination technique) was performed. RESULTS: At the second measurement, inert gas shunt was 15 +/- 3% (mean +/- SD) during sevoflurane anesthesia versus 9 +/- 1% during propofol anesthesia (P = 0.02). Blood flow to normal ventilation/perfusion (V(A)/Q) lung areas was 83 +/- 5% during sevoflurane anesthesia versus 89 +/- 1% during propofol anesthesia (P = 0.04). This resulted in a PaO2 of 88 +/- 11 mmHg during sevoflurane anesthesia versus 102 +/- 15 mmHg during propofol anesthesia (P = 0.04). Inert gas and blood gas variables during isoflurane anesthesia did not differ significantly from those obtained during propofol anesthesia. CONCLUSIONS: In pigs with an already existent gas exchange defect, sevoflurane anesthesia but not isoflurane anesthesia causes significantly more gas exchange disturbances than propofol anesthesia does.


Assuntos
Anestésicos Inalatórios/farmacologia , Isoflurano/farmacologia , Éteres Metílicos/farmacologia , Pneumoperitônio/fisiopatologia , Troca Gasosa Pulmonar/efeitos dos fármacos , Equilíbrio Ácido-Base/efeitos dos fármacos , Anestesia , Anestésicos Intravenosos/farmacologia , Animais , Gasometria , Gases Nobres , Propofol/farmacologia , Sevoflurano , Suínos
11.
Anaesthesia ; 56(3): 248-50, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11251432

RESUMO

Congenital or acquired forms of the long Q-T syndrome may result in ventricular tachycardia known as torsade de pointes. Many drugs including volatile anaesthetics modify the Q-T interval. Sevoflurane is known to prolong of the rate-corrected Q-T interval (Q-Tc). The objective of this study was to determine whether the sevoflurane-associated Q-Tc prolongation is rapidly reversible when propofol is substituted for sevoflurane. Thirty-two female patients were allocated to two groups. All patients received sevoflurane induction and anaesthesia for 15 min. In one group, sevoflurane was then discontinued and anaesthesia maintained on propofol for another 15 min. The second group received sevoflurane anaesthesia for 30 min. Measurements were taken before, and 15, 20, 25 and 30 min after induction. Q-Tc prolongation was significantly reduced 5, 10 and 15 min after propofol had been substituted for sevoflurane. We conclude that the sevoflurane-associated Q-Tc prolongation is fully reversible within 15 min when propofol is substituted for sevoflurane.


Assuntos
Anestésicos Inalatórios/efeitos adversos , Anestésicos Intravenosos/uso terapêutico , Síndrome do QT Longo/tratamento farmacológico , Éteres Metílicos/efeitos adversos , Propofol/uso terapêutico , Adulto , Anestesia Geral/efeitos adversos , Eletrocardiografia/efeitos dos fármacos , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Complicações Intraoperatórias/induzido quimicamente , Complicações Intraoperatórias/tratamento farmacológico , Síndrome do QT Longo/induzido quimicamente , Sevoflurano
12.
Am J Respir Crit Care Med ; 163(2): 339-43, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11179103

RESUMO

The effects of sildenafil (Viagra) on hemodynamics and pulmonary gas exchange remain uncertain. The aim of this study was to investigate what effect sildenafil had on gas exchange. A total of 24 anesthetized pigs were randomly assigned into four groups of six animals each: Group Low received 25 mg of sildenafil, which is equivalent to half the recommended dose for humans; group Normal received 50 mg; group High received 100 mg; and one group served as control. Inert gas and hemodynamic measurements were performed to define dose-dependent effects of sildenafil on cardiac and pulmonary function. Measurements were taken 30, 60, and 90 min after the administration of sildenafil via gastric tube. All doses of sildenafil caused significant increases in intrapulmonary shunt flow (maximum amplitude, 4.4 +/- 0.3 to 11.9 +/- 0.5%; mean +/- SEM), which was reflected by marked decreases in PaO2. Sildenafil elicited some significant increases in cardiac index (CI) (high dose, 142 +/- 10 to 196 +/- 13 ml x kg(-1), mean +/- SEM). Mean arterial pressure was significantly depressed after the high dose of sildenafil. Pulmonary artery pressure was decreased after high-dose sildenafil (maximum amplitude, 16 +/- 1.6 to 14 +/- 1.8, mean +/- SEM). No significant differences between the three treatment groups were found. Sildenafil represents and orally active substance with phosphodiesterase V inhibitory and cardiac output-increasing actions. PaO2 decrease after 50 and 100 mg of sildenafil was observed in the presence of significant rises in pulmonary shunt flow and CI.


Assuntos
Hemodinâmica/efeitos dos fármacos , Pulmão/irrigação sanguínea , Inibidores de Fosfodiesterase/farmacologia , Piperazinas/farmacologia , Troca Gasosa Pulmonar/efeitos dos fármacos , Vasodilatadores/farmacologia , 3',5'-GMP Cíclico Fosfodiesterases , Animais , Débito Cardíaco/efeitos dos fármacos , Nucleotídeo Cíclico Fosfodiesterase do Tipo 5 , Relação Dose-Resposta a Droga , Feminino , Masculino , Oxigênio/sangue , Diester Fosfórico Hidrolases/fisiologia , Pressão Propulsora Pulmonar/efeitos dos fármacos , Purinas , Citrato de Sildenafila , Sulfonas , Suínos
13.
J Nurs Adm ; 31(1): 40-8, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11198841

RESUMO

It takes a relatively long time for new nursing graduates to become oriented and comfortable with work routines on the nursing unit. To address the problem, the authors formed a partnership among three educational programs and three hospitals. This article describes a 900-hour residency program for senior baccalaureate nursing students to ease their transition into the role of beginning-level staff nurse in an acute-care setting. The benefits to the hospitals were decreased orientation time, less turnover in staff (50% at 2 years), and lower recruitment costs.


Assuntos
Bacharelado em Enfermagem/organização & administração , Capacitação em Serviço/organização & administração , Internato não Médico/organização & administração , Modelos Educacionais , Recursos Humanos de Enfermagem Hospitalar/educação , Avaliação de Programas e Projetos de Saúde , Atitude do Pessoal de Saúde , Competência Clínica , Coleta de Dados , Custos Hospitalares , Humanos , Enfermeiros Administradores , Pesquisa em Educação em Enfermagem , Recursos Humanos de Enfermagem Hospitalar/normas , Projetos Piloto , Preceptoria/organização & administração , Socialização , South Dakota
14.
Eur J Anaesthesiol ; 17(11): 662-4, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11029563

RESUMO

Thirty-six unpremedicated women due for gynaecological surgery were examined for time-dependent prolongation of the QT interval in the electrocardiogram (ECG) before and after induction of anaesthesia using either sevoflurane or propofol. The conventional inhalational technique to induce anaesthesia with sevoflurane. ECG recordings were taken before, 2, 5 and 10 min after drug administration. Sevoflurane significantly lengthened (P < 0.001) the heart rate corrected QT interval within 10 min from 434 +/- 5 ms to 459 +/- 6 ms (mean +/- SEM). Already after 2 min of sevoflurane application a trend towards prolongation was visible. The critical value of 440 ms in the rate-corrected QT interval was exceeded in four patients in the sevoflurane group (n = 18) but in only in one patient in the propofol group (n = 18). Rate-corrected QT interval prolongation caused by sevoflurane needs to be recognized early in order to prevent the critical ventricular tachycardia torsade de pointes.


Assuntos
Anestésicos Inalatórios/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Éteres Metílicos/administração & dosagem , Adulto , Análise de Variância , Anestésicos Intravenosos/administração & dosagem , Pressão Sanguínea/efeitos dos fármacos , Feminino , Seguimentos , Genitália Feminina/cirurgia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Propofol/administração & dosagem , Sevoflurano , Método Simples-Cego , Fatores de Tempo , Torsades de Pointes/prevenção & controle
15.
Anesth Analg ; 91(4): 1017-20, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11004067

RESUMO

In this randomized, cross-over cadaver study, we determined whether a new airway device, the ProSeal laryngeal mask airway (PLMA; Laryngeal Mask Company, Henley-on-Thames, UK), prevents aspiration of regurgitated fluid. We studied five male and five female cadavers (6-24 h postmortem). The infusion set of a pressure-controlled, continuous flow pump was inserted into the upper esophagus and ligated into place. Esophageal pressure (EP) was increased in 2-cm H(2)O increments. This was performed without an airway device (control) and over a range of cuff volumes (0-40 mL) for the classic laryngeal mask airway (LMA), the PLMA with the drainage tube clamped (PLMA clamped) and unclamped (PLMA unclamped). The EP at which fluid was first seen with a fiberoptic scope in the hypopharynx (control), above or below the cuff, or in the drainage tube, was noted. Mean EP at which fluid was seen without any airway device was 9 (range 8-10) cm H(2)O. EP at which fluid was seen was always higher for the PLMA clamped and LMA compared with the control (all, P<0.0001). The mean EP at which fluid was seen for the PLMA unclamped was similar to the control at 10 (range 8-13) cm H(2)O. For the PLMA unclamped, fluid appeared from the drainage tube in all cadavers at 10-40 mL cuff volume and in 8 of 10 cadavers at zero cuff volume. Mean EP at which fluid was seen above the cuff was similar for the PLMA clamped and LMA at 0-30 mL cuff volume, but was higher for PLMA clamped at 40-mL cuff volume (81 vs 48 cm H(2)O, P = 0.006). Mean EP at which fluid was seen below the cuff was similar at 0-10 mL cuff volume, but was higher for the PLMA clamped at 20, 30, and 40 mL cuff volume (62, 68, 73 vs. 46, 46, 46 cm H(2)O, respectively, P<0.04). For the PLMA clamped and the LMA, fluid appeared simultaneously above and below the cuff at all cuff volumes. We concluded that in the cadaver model, the correctly placed PLMA allows fluid in the esophagus to bypass the pharynx and mouth when the drainage tube is open. Both the LMA, and PLMA with a closed drainage tube, attenuate liquid flow between the esophagus and pharynx. This may have implications for airway protection in unconscious patients.


Assuntos
Corpos Estranhos/prevenção & controle , Máscaras Laríngeas , Traqueia , Vômito/complicações , Idoso , Idoso de 80 Anos ou mais , Cadáver , Constrição , Estudos Cross-Over , Drenagem/instrumentação , Desenho de Equipamento , Esôfago/fisiopatologia , Feminino , Tecnologia de Fibra Óptica/instrumentação , Refluxo Gastroesofágico/complicações , Humanos , Laringoscópios , Masculino , Pessoa de Meia-Idade , Boca , Faringe , Pneumonia Aspirativa/prevenção & controle , Pressão
16.
Anesth Analg ; 91(3): 522-7, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10960369

RESUMO

UNLABELLED: Postbypass pulmonary dysfunction including atelectasis and increased shunting is a common problem in the intensive care unit. Negative net fluid balance and continuous positive airway pressure (CPAP) have been used to reduce the adverse effects of cardiopulmonary bypass (CPB) on the lung. To determine whether CPAP at 10 cm H(2)O during CPB results in improved postoperative gas exchange in comparison with deflated lungs during CPB, we examined 14 patients scheduled for elective cardiac surgery. Seven patients received CPAP at 10 cm H(2)O during CPB, and in the other seven patients, the lungs were open to the atmosphere (control). Measurements were taken before and after CPB, after thoracic closure, and 4 h after CPB in the intensive care unit. CPAP at 10 cm H(2)O resulted in significantly more perfusion of lung areas with a normal ventilation/perfusion distribution (V(A)/Q) and significantly less shunt and low V(A)/Q perfusion 4 h after CPB in comparison with the control group. Consequently, arterial oxygen partial pressure was significantly higher and alveolar-arterial oxygen partial pressure difference was significantly smaller. We conclude that CPAP at 10 cm H(2)O during CPB is a simple maneuver that improves postoperative gas exchange. IMPLICATIONS: Inflation of the lungs at a pressure of 10 cm H(2)O as compared with leaving the lungs deflated during cardiopulmonary bypass was examined. Lung inflation during bypass resulted in significantly improved postoperative gas exchange.


Assuntos
Ponte Cardiopulmonar/métodos , Respiração com Pressão Positiva , Troca Gasosa Pulmonar/fisiologia , Idoso , Feminino , Humanos , Complacência Pulmonar/fisiologia , Masculino , Gases Nobres , Período Pós-Operatório , Mecânica Respiratória/fisiologia , Relação Ventilação-Perfusão/fisiologia
17.
Can J Anaesth ; 47(4): 347-9, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10764181

RESUMO

PURPOSE: Controversial data about the effect of smoking on the dose-requirements and the pharamcodynamics of rocuronium have been reported recently. This study was conducted to evaluate the dose-requirements and the pharmacodynamics of rocuronium in smokers using target controlled infusion. METHODS: The dose-requirements of rocuronium for 60 min relaxation, using target controlled infusion, given under intravenous anaesthesia with propofol, fentanyl and nitrous oxide was studied in 37 smokers and 37 non-smokers. Initially 450 microg x kg(-1) rocuronium were administered, neuromuscular effects were quantified by recording the single twitch response of the adductor pollicis muscle after ulnar nerve stimulation using a force transducer, and the neuromuscular block was kept at 80% by target controlled infusion throughout the procedure. RESULTS: The dose-requirements for one hour relaxation were 867 +/- 116 microg x kg(-1) x hr(-1) for smokers (S) and 839 +/- 149 microg x kg(-1) x hr(-1) for non-smokers (NS). The duration to 10% and the spontaneous recovery from 25% to 75% of the control twitch response also showed no differences between S (17.2 +/- 3.4 min, 10.6 +/- 0.9 min) and NS (18.9 +/- 4.3 min, 10.9 +/- 3.2 min), as well as maximum block, onset time and infusion rate. CONCLUSION: Smoking does not alter the dose-requirements for rocuronium and no effects on the onset time, degree of block, time to maximum block, duration 10% and spontaneous recovery index were observed.


Assuntos
Androstanóis/administração & dosagem , Fármacos Neuromusculares não Despolarizantes/efeitos adversos , Fumar/fisiopatologia , Adulto , Relação Dose-Resposta a Droga , Estimulação Elétrica , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiologia , Rocurônio
18.
Anaesthesist ; 49(2): 102-5, 2000 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-10756963

RESUMO

OBJECTIVE: The aim of the study was to evaluate the effect of two different priming regimen on the onset time of 100 micrograms/kg cisatracurium, when compared to bolus administration. METHODS: 51 patients were randomly assigned and received either a bolus of 100 micrograms/kg cisatracurium, or a priming dose of 10 micrograms/kg cisatracurium followed after 4 min by 90 micrograms/kg cisatracurium, or a priming dose of 15 micrograms/kg cisatracurium followed after 4 min by 85 micrograms/kg cisatracurium. The neuromuscular monitoring was performed using a mechanomyograph (Groningen II Monitor). Anaesthesia was induced with propofol and fentanyl and maintained by continuous infusion of propofol. RESULTS: The priming combination of 15 micrograms/kg cisatracurium followed after 4 min by 85 micrograms/kg cisatracurium produced a statistically significant reduction in the onset time (95% block) (180 +/- 60 s) and time to complete block (210 +/- 48 s), when compared to the bolus group (240 +/- 60 s and 288 +/- 66 s) (p < 0.05). CONCLUSION: Our data indicate that the "priming principle" is an appropriate technique to shorten the onset time of cisatracurium. To achieve a maximum effect the priming combination of 15 micrograms/kg cisatracurium followed after 4 min by 85 micrograms/kg cisatracurium is recommended.


Assuntos
Anestesia , Atracúrio/análogos & derivados , Bloqueadores Neuromusculares/administração & dosagem , Bloqueadores Neuromusculares/farmacologia , Adulto , Anestesia Intravenosa , Anestésicos Intravenosos , Atracúrio/administração & dosagem , Atracúrio/farmacologia , Feminino , Fentanila , Humanos , Masculino , Miografia , Propofol
19.
Anesthesiology ; 92(5): 1237-41, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10781267

RESUMO

BACKGROUND: The authors compared airway management in normogravity and simulated microgravity with and without restraints for laryngoscope-guided tracheal intubation, the cuffed oropharyngeal airway, the standard laryngeal mask airway, and the intubating laryngeal mask airway. METHODS: Four trained anesthesiologist-divers participated in the study. Simulated microgravity during spaceflight was obtained using a submerged, full-scale model of the International Space Station Life Support Module and neutrally buoyant equipment and personnel. Customized, full-torso manikins were used for performing airway management. Each anesthesiologist-diver attempted airway management on 10 occasions with each device in three experimental conditions: (1) with the manikin at the poolside (poolside); (2) with the submerged manikin floating free (free-floating); and (3) with the submerged manikin fixed to the floor using a restraint (restrained). Airway management failure was defined as failed insertion after three attempts or inadequate device placement after insertion. RESULTS: For the laryngoscope-guided tracheal intubation, airway management failure occurred more frequently in the free-floating (85%) condition than the restrained (8%) and poolside (0%) conditions (both, P < 0.001). Airway management failure was similar among conditions for the cuffed oropharyngeal airway (poolside, 10%; free-floating, 15%; restrained, 15%), laryngeal mask airway (poolside, 0%; free-floating, 3%; restrained, 0%), and intubating laryngeal mask airway (poolside, 5%; free-floating, 5%; restrained, 10%). Airway management failure for the laryngoscope-guided tracheal intubation was usually caused by failed insertion (> 90%), and for the cuffed oropharyngeal airway, laryngeal mask airway, and intubating laryngeal mask airway, it was always a result of inadequate placement. CONCLUSION: The emphasis placed on the use of restraints for conventional tracheal intubation in microgravity is appropriate. Extratracheal airway devices may be useful when restraints cannot be applied or intubation is difficult.


Assuntos
Medicina Aeroespacial/métodos , Intubação Intratraqueal/instrumentação , Máscaras Laríngeas , Laringoscopia , Adulto , Gravitação , Humanos , Intubação Intratraqueal/métodos , Masculino , Manequins
20.
Anesth Analg ; 90(1): 25-7, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10624970

RESUMO

UNLABELLED: Prolongation of the Q-T interval may be associated with polymorphic ventricular tachycardia known as torsade de pointes, syncope and sudden death. Existing data show that isoflurane prolongs the Q-T interval, whereas halothane shortens it. The aim of this study was to determine whether sevoflurane or propofol affects the Q-T interval. Thirty female patients undergoing gynecologic surgery were randomly assigned to two groups, one receiving inhaled induction with sevoflurane and the other receiving total IV anesthesia with propofol. Before and 20 min after the induction, a six-lead electrocardiogram was recorded, and blood pressure was measured. The Q-T interval and heart rate adjusted Q-T interval (Q-Tc interval) were significantly prolonged during the administration of anesthesia with sevoflurane, while the Q-T interval was significantly shortened, and the Q-Tc interval was statistically unaffected during propofol anesthesia administration. We conclude that, in otherwise healthy female patients, sevoflurane prolongs the Q-Tc. IMPLICATIONS: In this study, we evaluated the effect of sevoflurane induction and anesthesia versus propofol induction and anesthesia on the Q-T interval. Sevoflurane significantly prolonged the Q-T interval and the heart rate adjusted Q-T interval, whereas propofol shortened the Q-T interval but not the heart rate adjusted Q-T interval.


Assuntos
Anestésicos Inalatórios/efeitos adversos , Anestésicos Intravenosos/efeitos adversos , Eletrocardiografia/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Éteres Metílicos/efeitos adversos , Propofol/efeitos adversos , Adulto , Feminino , Procedimentos Cirúrgicos em Ginecologia , Hemodinâmica/efeitos dos fármacos , Humanos , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...