Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Nano ; 15(6): 9577-9587, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34014640

RESUMO

Interactions between polymers and surfaces can be used to influence properties including mechanical performance in nanocomposites, the glass transition temperature, and the orientation of thin film block copolymers (BCPs). In this work we investigate how specific interactions between the substrate and BCPs with varying substrate affinity impact the interfacial width between polymer components. The interface width is generally assumed to be a function of the BCP properties and independent of the surface affinity or substrate proximity. Using resonant soft X-ray reflectivity the optical constants of the film can be controlled by changing the incident energy, thereby varying the depth sensitivity of the measurement. Resonant soft X-ray reflectivity measurements were conducted on films of polystyrene-b-poly(2-vinylpyridine) (PS-b-P2VP) and PS-b-poly(methyl methacrylate) (PS-b-PMMA), where the thickness of the film was varied from half the periodicity (L0) of the BCP to 5.5 L0. The results of this measurement on the PS-b-P2VP films show a significant expansion of the interface width immediately adjacent to the surface. This is likely caused by the strong adsorption of P2VP to the substrate, which constrains the mobility of the junction points, preventing them from reaching their equilibrium distribution and expanding the observed interface width. The interface width decays toward equilibrium moving away from the substrate, with the decay rate being a function of film thickness below a critical limit. The PMMA block appears to be more mobile, and the BCP interfaces near the substrate match their equilibrium value.

2.
J Phys Condens Matter ; 33(16)2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33498032

RESUMO

We present the design and performance of a polarized resonant soft x-ray scattering (RSoXS) station for soft matter characterization built by the national institute of standards and technology at the national synchrotron light source-II (NSLS-II). The RSoXS station is located within the spectroscopy soft and tender beamline suite at NSLS-II located in Brookhaven national laboratory, New York. Numerous elements of the RSoXS station were designed for optimal performance for measurements on soft matter systems, where it is of critical importance to minimize beam damage and maximize collection efficiency of polarized x-rays. These elements include a novel optical design, sample manipulator and sample environments, as well as detector setups. Finally, we will report the performance of the measurement station, including energy resolution, higher harmonic content and suppression methods, the extent and mitigation of the carbon absorption dip on optics, and the range of polarizations available from the elliptically polarized undulator source.

3.
ACS Nano ; 14(12): 17476-17486, 2020 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-33225683

RESUMO

Bottlebrush block copolymers (BBCPs) are intriguing architectural variations on linear BCPs with highly tunable structure. Confinement can have a significant impact on polymer assembly, giving rise to changes in morphology, assembly kinetics, and properties like the glass transition. Given that confinement leads to significant changes in the persistence length of bottlebrush homopolymers, it is reasonable to expect that BBCPs will see significant changes in their structure and periodicity relative to the bulk morphology. Understanding how confinement influences assembly will be important for designing BBCPs for thin film applications including membranes, integrated photonic structures, and potentially BCP lithography. In order to study the effects of confinement on BBCP conformation and morphology, a blade coating was used to prepare films with continuous variation in film thickness. Unlike thin films of linear BCPs, islands/holes were not observed, and instead mixtures of parallel and perpendicular morphologies emerge after annealing. The lamellar periodicity (L0) of the morphologies is found to be thickness dependent, increasing L0 with decreasing film thickness for blade coated films. Films coated out of tetrahydrofuran (THF) resulted in a single well-defined lamellar periodicity, verified through atomic force microscopy (AFM) and grazing incidence small-angle X-ray scattering (GISAXS), which increases dramatically from the bulk value (30.6 nm) and continues to increase as the film thickness decreases. The largest observed L0 was 65.5 nm, and this closely approaches the estimated upper limit of 67 nm corresponding to a fully extended backbone in a bilayer arrangement. Films coated out of propylene glycol methyl ether acetate (PGMEA) resulted in a mixture of perpendicular lamellae and a smaller, likely cylindrical morphology. The lamellar portion of the film shows the same thickness dependence as the lamellae observed in the THF coated films. The scaling of the lamellar L0 with respect to film thickness follows predictions for confined semiflexible polymers with weak excluded volume interactions and can be related to models for confinement of DNA. Spin coated films shows the same reduction in periodicity, although at very different film thicknesses. This result suggests that the material has shallow free-energy barriers to transitioning between different L0 and morphologies, a property that could be taken advantage of for patterning diverse structures with a single material.

4.
Adv Energy Mater ; 10(8)2020.
Artigo em Inglês | MEDLINE | ID: mdl-33071704

RESUMO

The temperature dependent aggregation behavior of PffBT4T polymers used in organic solar cells plays a critical role in the formation of a favorable morphology in fullerene-based devices. However, there has been little investigation into the impact of donor/acceptor ratio on morphology tuning, especially for non-fullerene acceptors (NFAs). Herein, the influence of composition on morphology is reported for blends of PffBT4T-2DT with two NFAs, O-IDTBR and O-IDFBR. The monotectic phase behavior inferred from differential scanning calorimetry provides qualitative insight into the interplay between solid-liquid and liquid-liquid demixing. Transient absorption spectroscopy suggests that geminate recombination dominates charge decay and that the decay rate is insensitive to composition, corroborated by negligible changes in open-circuit voltage. Exciton lifetimes are also insensitive to composition, which is attributed to the signal being dominated by acceptor excitons which are formed and decay in domains of similar size and purity irrespective of composition. A hierarchical morphology is observed, where the composition dependence of size scales and scattering intensity from resonant soft X-ray scattering (R-SoXS) is dominated by variations in volume fractions of polymer/polymer rich domains. Results suggest an optimal morphology where polymer crystallite size and connectivity are balanced, ensuring a high probability of hole extraction via such domains.

5.
Chem Mater ; 32(6)2020.
Artigo em Inglês | MEDLINE | ID: mdl-33100517

RESUMO

The challenges of patterning next generation integrated circuits have driven the semiconductor industry to look outside of traditional lithographic methods in order to continue cost effective size scaling. The directed self-assembly (DSA) of block copolymers (BCPs) is a nanofabrication technique used to reduce the periodicity of patterns prepared with traditional optical methods. BCPs with large interaction parameters (χ eff), provide access to smaller pitches and reduced interface widths. Larger χ eff is also expected to be correlated with reduced line edge roughness (LER), a critical performance parameter in integrated circuits. One approach to increasing χ eff is blending the BCP with a phase selective additive, such as an Ionic liquid (IL). The IL does not impact the etching rates of either phase, and this enables a direct interrogation of whether the change in interface width driven by higher χ eff translates into lower LER. The effect of the IL on the layer thickness and interface width of a BCP are examined, along with the corresponding changes in LER in a DSA patterned sample. The results demonstrate that increased χ eff through additive blending will not necessarily translate to a lower LER, clarifying an important design criterion for future material systems.

6.
ACS Appl Mater Interfaces ; 12(20): 23399-23409, 2020 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-32345022

RESUMO

Polarity-switching photopatternable guidelines can be directly used to both orient and direct the self-assembly of block copolymers. We report the orientation and alignment of poly(styrene-block-4-trimethylsilylstyrene) (PS-b-PTMSS) with a domain periodicity, L0, of 44 nm on thin photopatternable grafting surface treatments (pGSTs) and cross-linkable surface treatments (pXSTs), containing acid-labile 4-tert-butoxystyrene monomer units. The surface treatment was exposed using electron beam lithography to create well-defined linear arrays of neutral and preferential regions. Directed self-assembly (DSA) of PS-b-PTMSS with much lower defectivity was observed on pXST than on pGST guidelines. The study of the effect of film thickness on photoacid diffusion by Fourier transform infrared spectroscopy and near-edge X-ray absorption fine structure spectroscopy suggested slower diffusion in thinner films, potentially enabling production of guidelines with sharper interfaces between the unexposed and exposed lines, and thus, the DSA of PS-b-PTMSS on thinner pXST guidelines resulted in better alignment control.

7.
Sci Adv ; 6(13): eaay5986, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32258402

RESUMO

Liquid crystal blue phases (BPs) are three-dimensional soft crystals with unit cell sizes orders of magnitude larger than those of classic, atomic crystals. The directed self-assembly of BPs on chemically patterned surfaces uniquely enables detailed in situ resonant soft x-ray scattering measurements of martensitic phase transformations in these systems. The formation of twin lamellae is explicitly identified during the BPII-to-BPI transformation, further corroborating the martensitic nature of this transformation and broadening the analogy between soft and atomic crystal diffusionless phase transformations to include their strain-release mechanisms.

9.
Artigo em Inglês | MEDLINE | ID: mdl-33033414

RESUMO

The directed self-assembly (DSA) of block copolymers (BCPs) is a promising low-cost approach to patterning structures with critical dimensions (CDs) which are smaller than can be achieved by traditional photolithography. The CD of contact holes can be reduced by assembling a cylindrical BCP inside a patterned template and utilizing the native size of the cylinder to dictate the reduced dimensions of the hole. This is a particularly promising application of the DSA technique, but in order for this technology to be realized there is a need for three-dimensional metrology of the internal structure of the patterned BCP in order to understand how template properties and processing conditions impact BCP assembly. This is a particularly challenging problem for traditional metrologies owing to the three-dimensional nature of the structure and the buried features. By utilizing small-angle X-ray scattering and changing the angle between the incident beam and sample we can reconstruct the three-dimensional shape profile of the empty template and the residual polymer after self-assembly and removal of one of the phases. A two-dimensional square grid pattern of the holes results in scattering in both in-plane directions, which is simplified by converting to a radial geometry. The shape is then determined by simulating the scattering from a model and iterating that model until the simulated and experimental scattering profiles show a satisfactory match. Samples with two different processing conditions are characterized in order to demonstrate the ability of the technique to evaluate critical features such as residual layer thickness and sidewall height. It was found that the samples had residual layer thicknesses of 15.9 ± 3.2 nm and 4.5 ± 2.2 nm, which were clearly distinguished between the two different DSA processes and in good agreement with focused ion beam scanning transmission electron microscopy (FIBSTEM) observations. The advantage of the X-ray measurements is that FIBSTEM characterizes around ten holes, while there are of the order of 800 000 holes illuminated by the X-ray beam.

10.
ACS Appl Mater Interfaces ; 11(3): 3280-3289, 2019 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-30592202

RESUMO

Stretchable conductive polymer films are required to survive not only large tensile strain but also stay functional after the reduction in applied strain. In the deformation process, the elastomer substrate that is typically employed plays a critical role in response to the polymer film. In this study, we examine the role of a polydimethylsiloxane (PDMS) elastomer substrate on the ability to achieve stretchable PDPP-4T films. In particular, we consider the adhesion and near-surface modulus of the PDMS tuned through UV/ozone (UVO) treatment on the competition between film wrinkling and plastic deformation. We also consider the role of PDMS tension on the stability of films under cyclic strain. We find that increasing the near-surface modulus of the PDMS and maintaining the PDMS in tension throughout the cyclic strain process promote plastic deformation over film wrinkling. In addition, the UVO treatment increases film adhesion to the PDMS resulting in a significantly reduced film folding and delamination. For a 20 min UVO-treated PDMS, we show that a PDPP-4T film root-mean-square roughness is consistently below 3 nm for up to 100 strain cycles with a strain range of 40%. In addition, although the film is plastically deforming, the microstructural order is largely stable as probed by grazing incidence X-ray scattering and UV-visible spectroscopy. These results highlight the importance of neighboring elastomer characteristics on the ability to achieve stretchable polymer semiconductors.

11.
J Synchrotron Radiat ; 25(Pt 4): 1261-1270, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979189

RESUMO

Xi-cam is an extensible platform for data management, analysis and visualization. Xi-cam aims to provide a flexible and extensible approach to synchrotron data treatment as a solution to rising demands for high-volume/high-throughput processing pipelines. The core of Xi-cam is an extensible plugin-based graphical user interface platform which provides users with an interactive interface to processing algorithms. Plugins are available for SAXS/WAXS/GISAXS/GIWAXS, tomography and NEXAFS data. With Xi-cam's `advanced' mode, data processing steps are designed as a graph-based workflow, which can be executed live, locally or remotely. Remote execution utilizes high-performance computing or de-localized resources, allowing for the effective reduction of high-throughput data. Xi-cam's plugin-based architecture targets cross-facility and cross-technique collaborative development, in support of multi-modal analysis. Xi-cam is open-source and cross-platform, and available for download on GitHub.

12.
Mol Syst Des Eng ; 3(2): 376-389, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29892480

RESUMO

A block copolymer self-consistent field theory (SCFT) model is used for direct analysis of experimental X-ray scattering data obtained from thin films of polystyrene-b-poly(methyl methacrylate) (PS-b-PMMA) made from directed self-assembly. In a departure from traditional approaches, which reconstruct the real space structure using simple geometric shapes, we build on recent work that has relied on physics-based models to determine shape profiles and extract thermodynamic processing information from the scattering data. More specifically, an SCFT model, coupled to a covariance matrix adaptation evolutionary strategy (CMAES), is used to find the set of simulation parameters for the model that best reproduces the scattering data. The SCFT model is detailed enough to capture the essential physics of the copolymer self-assembly, but sufficiently simple to rapidly produce structure profiles needed for interpreting the scattering data. The ability of the model to produce a matching scattering profile is assessed, and several improvements are proposed in order to more accurately recreate the experimental observations. The predicted parameters are compared to those extracted from model fits via additional experimental methods and with predicted parameters from direct particle-based simulations of the same model, which incorporate the effects of fluctuations. The Flory-Huggins interaction parameter for PS-b-PMMA is found to be in agreement with reported ranges for this material. These results serve to strengthen the case for relying on physics-based models for direct analysis of scattering and light signal based experiments.

13.
Macromolecules ; 51(1): 173-180, 2018 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-29706666

RESUMO

Advancements in the directed self-assembly of block copolymers (BCPs) have prompted the development of new materials with larger effective interaction parameters (χe). This enables BCP systems with phase separation at increasingly small degrees of polymerization (N). Very often these systems reside near the order-disorder transition and fit between the weak and strong segregation limits where the behavior of BCP systems is not as thoroughly understood. Utilizing resonant soft X-ray reflectivity (RSoXR) enables both the BCP pitch (L0) and interface width (wM) to be determined simultaneously, through a direct characterization of the composition profile of BCP lamellae oriented parallel to a substrate. A series of high χe BCPs with χe ranging from ≈0.04 to 0.25 and χeN from 19 to 70 have been investigated. The L0/wm ratio serves as an important metric for the feasibility of a material for nanopatterning applications; the results of the RSoXR measurement are used to establish a relationship between χe and L0/wm. The results of this analysis are correlated with experimentally established limits for the functionality of BCPs in nanopatterning applications. These results also provide guidance for the magnitude of χe needed to achieve small interface width for samples with sub-10 nm L0.

14.
Artigo em Inglês | MEDLINE | ID: mdl-33033553

RESUMO

Optimizing the extraction of information from x-ray measurements while minimizing exposure time is an important area of research in a variety of fields. The semiconductor industry is reaching a point where the traditional optical metrologies need to be augmented in order to better resolve the critical dimensions of structures with feature sizes below 10 nm. Critical dimension small angle x-ray scattering (CDSAXS) is one measurement technique that is capable of characterizing detailed features of periodic nanostructures. As currently implemented, the measurement utilizes the combined scattering from up to 60 different angles. Reducing the number of angles would dramatically improve the feasibility of CDSAXS for implementation in a fabrication setting, but currently there are no clear guidelines as to which angles provide the most information to minimize the uncertainty in the shape of the target structure while maximizing the throughput. In order to develop guidelines for optimizing the angle selection, simulation studies were conducted on a wide variety of structures with subsets of the full angular range to identify which angles minimized the overall shape uncertainty. Analyzing sets of two angle pairs (including all combinations between 0 deg and 60 deg) provides guidance on which angles best constrain the samples. For select samples, higher numbers of angles were included to explore the impact of additional information on the model uncertainty. In general, low angles (<3 deg) best contributed to minimizing the line-width uncertainty, while higher angles near high curvature regions of the scattering profile best constrained the height of the structure. The minimum uncertainty was generally achieved with combinations of the two. This simulation approach can be used to minimize the number of angles measured on real samples and significantly reduce the measurement time.

15.
Adv Electron Mater ; 3(1)2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28690975

RESUMO

Intrinsically stretchable semiconductors will facilitate the realization of seamlessly integrated stretchable electronics. However, to date demonstrations of intrinsically stretchable semiconductors have been limited. In this study, a new approach to achieve intrinsically stretchable semiconductors is introduced by blending a rigid high-performance donor-acceptor polymer semiconductor poly[4(4,4dihexadecyl4Hcyclopenta [1,2b:5,4b' ] dithiopen2yl) alt [1,2,5] thiadiazolo [3,4c] pyridine] (PCDTPT) with a ductile polymer semiconductor poly(3hexylthiophene) (P3HT). Under large tensile strains of up to 75%, the polymers are shown to orient in the direction of strain, and when the strain is reduced, the polymers reversibly deform. During cyclic strain, the local packing order of the polymers is shown to be remarkably stable. The saturated field effect charge mobility is shown to be consistently above 0.04 cm2 V-1s-1 for up to 100 strain cycles with strain ranging from 10% to 75% when the film is printed onto a rigid test bed. At the 75% strain state, the charge mobility is consistently above 0.15 cm2 V-1s-1. Ultimately, the polymer blend process introduced here results in an excellent combination of device performance and stretchability providing an effective approach to achieve intrinsically stretchable semiconductors.

16.
ACS Appl Mater Interfaces ; 9(37): 31325-31334, 2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-28541658

RESUMO

The directed self-assembly (DSA) of block copolymers (BCPs) is a potential solution for patterning critical features for integrated circuits at future technology nodes. For this process to be implemented, there needs to be a better understanding of how the template guides the assembly and induces subsurface changes in the lamellar structure. Using a rotational transmission X-ray scattering measurement coupled with soft X-rays to improve contrast between polymer components, the impact of the ratio of the guiding stripe width (W) to the BCP pitch (L0) was investigated. For W/L0 < 1, continuous vertical lamella were observed, with some fluctuations in the interface profile near the template that smoothed out further up the structure. Near W/L0 ≈ 1.5, the arrangement of the lamella shifted, moving from polystyrene centered on the guiding stripe to poly(methyl methacrylate) centered on the guiding stripe.

17.
J Appl Crystallogr ; 50(Pt 2): 462-474, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28381972

RESUMO

The certification of a new standard reference material for small-angle scattering [NIST Standard Reference Material (SRM) 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering (SAXS)], based on glassy carbon, is presented. Creation of this SRM relies on the intrinsic primary calibration capabilities of the ultra-small-angle X-ray scattering technique. This article describes how the intensity calibration has been achieved and validated in the certified Q range, Q = 0.008-0.25 Å-1, together with the purpose, use and availability of the SRM. The intensity calibration afforded by this robust and stable SRM should be applicable universally to all SAXS instruments that employ a transmission measurement geometry, working with a wide range of X-ray energies or wavelengths. The validation of the SRM SAXS intensity calibration using small-angle neutron scattering (SANS) is discussed, together with the prospects for including SANS in a future renewal certification.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38680764

RESUMO

There is a need to characterize nanoscale molecular orientation in soft materials, and polarized scattering is a powerful means to measure this property. However, few approaches have been demonstrated that quantitatively relate orientation to scattering. Here, a modeling framework to relate the molecular orientation of nanostructures to polarized resonant soft X-ray scattering measurements is developed. A variable-angle transmission measurement called critical-dimension X-ray scattering enables the characterization of the three-dimensional shape of periodic nanostructures. When this measurement is conducted at resonant soft X-ray energies with different polarizations to measure soft material nanostructures, the scattering contains convolved information about the nanostructure shape and the preferred molecular orientation as a function of position, which is extracted by fitting using inverse iterative algorithms. A computationally efficient Born approximation simulation of the scattering has been developed, with a full tensor treatment of the electric field that takes into account biaxial molecular orientation, and this approach is validated by comparing it with a rigorous coupled wave simulation. The ability of various sample models to generate unique best fit solutions is then analyzed by generating simulated scattering pattern sets and fitting them with an inverse iterative algorithm. The interaction of the measurement geometry and the change in orientation across a periodic repeat unit leads to distinct asymmetry in the scattering pattern which must be considered for an accurate fit of the scattering.

19.
Artigo em Inglês | MEDLINE | ID: mdl-27551326

RESUMO

We compare the speed and effectiveness of two genetic optimization algorithms to the results of statistical sampling via a Markov chain Monte Carlo algorithm to find which is the most robust method for determining real space structure in periodic gratings measured using critical dimension small angle X-ray scattering. Both a covariance matrix adaptation evolutionary strategy and differential evolution algorithm are implemented and compared using various objective functions. The algorithms and objective functions are used to minimize differences between diffraction simulations and measured diffraction data. These simulations are parameterized with an electron density model known to roughly correspond to the real space structure of our nanogratings. The study shows that for X-ray scattering data, the covariance matrix adaptation coupled with a mean-absolute error log objective function is the most efficient combination of algorithm and goodness of fit criterion for finding structures with little foreknowledge about the underlying fine scale structure features of the nanograting.

20.
ACS Appl Mater Interfaces ; 8(22): 14037-45, 2016 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-27200458

RESUMO

Polymer semiconductors based on donor-acceptor monomers have recently resulted in significant gains in field effect mobility in organic thin film transistors (OTFTs). These polymers incorporate fused aromatic rings and have been designed to have stiff planar backbones, resulting in strong intermolecular interactions, which subsequently result in stiff and brittle films. The complex synthesis typically required for these materials may also result in increased production costs. Thus, the development of methods to improve mechanical plasticity while lowering material consumption during fabrication will significantly improve opportunities for adoption in flexible and stretchable electronics. To achieve these goals, we consider blending a brittle donor-acceptor polymer, poly[4-(4,4-dihexadecyl-4H-cyclopenta[1,2-b:5,4-b']dithiophen-2-yl)-alt-[1,2,5]thiadiazolo[3,4-c]pyridine] (PCDTPT), with ductile poly(3-hexylthiophene). We found that the ductility of the blend films is significantly improved compared to that of neat PCDTPT films, and when the blend film is employed in an OTFT, the performance is largely maintained. The ability to maintain charge transport character is due to vertical segregation within the blend, while the improved ductility is due to intermixing of the polymers throughout the film thickness. Importantly, the application of large strains to the ductile films is shown to orient both polymers, which further increases charge carrier mobility. These results highlight a processing approach to achieve high performance polymer OTFTs that are electrically and mechanically optimized.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...