Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 110(3): 745-756, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33508373

RESUMO

PURPOSE: Cardiac radioablation is a novel treatment option for therapy-refractory ventricular tachycardia (VT) ineligible for catheter ablation. Three-dimensional clinical target volume (CTV) definition is a key step, and this complex interdisciplinary procedure includes VT-substrate identification based on electroanatomical mapping (EAM) and its transfer to the planning computed tomography (PCT). Benchmarking of this process is necessary for multicenter clinical studies such as the RAVENTA trial. METHODS AND MATERIALS: For benchmarking of the RAVENTA trial, patient data (epicrisis, electrocardiogram, high-resolution EAM, contrast-enhanced cardiac computed tomography, PCT) of 3 cases were sent to 5 university centers for independent CTV generation, subsequent structure analysis, and consensus finding. VT substrates were first defined on multiple EAM screenshots/videos and manually transferred to the PCT. The generated structure characteristics were then independently analyzed (volume, localization, surface distance and conformity). After subsequent discussion, consensus structures were defined. RESULTS: VT substrate on the EAM showed visible variability in extent and localization for cases 1 and 2 and only minor variability for case 3. CTVs ranged from 6.7 to 22.9 cm3, 5.9 to 79.9 cm3, and 9.4 to 34.3 cm3; surface area varied from 1087 to 3285 mm2, 1077 to 9500 mm2, and 1620 to 4179 mm2, with a Hausdorff-distance of 15.7 to 39.5 mm, 23.1 to 43.5 mm, and 15.9 to 43.9 mm for cases 1 to 3, respectively. The absolute 3-dimensional center-of-mass difference was 5.8 to 28.0 mm, 8.4 to 26 mm, and 3.8 to 35.1 mm for cases 1 to 3, respectively. The entire process resulted in CTV structures with a conformity index of 0.2 to 0.83, 0.02 to 0.85, and 0.02 to 0.88 (ideal 1) with the consensus CTV as reference. CONCLUSIONS: Multicenter efficacy endpoint assessment of cardiac radioablation for therapy-refractory VT requires consistent CTV transfer methods from the EAM to the PCT. VT substrate definition and CTVs were comparable with current clinical practice. Remarkable differences regarding the degree of agreement of the CTV definition on the EAM and the PCT were noted, indicating a loss of agreement during the transfer process between EAM and PCT. Cardiac radioablation should be performed under well-defined protocols and in clinical trials with benchmarking and consensus forming.


Assuntos
Radiocirurgia , Taquicardia Ventricular/radioterapia , Benchmarking , Humanos
2.
Diagnostics (Basel) ; 10(12)2020 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-33322125

RESUMO

Ga-68-DOTATOC-PET/MRI can affect the planning target volume (PTV) definition of meningiomas before radiosurgery. A shorter tracer uptake time before image acquisition could allow the examination of more patients. The aim of this study was to investigate if shortening uptake time is possible without compromising diagnostic accuracy and PET volume. Fifteen patients (f = 12; mean age 52 years (34-80 years)) with meningiomas were prospectively examined with dynamic [68Ga]Ga-68-labeled [DOTA0-Phe1-Tyr3] octreotide (Ga-68-DOTATOC)-PET/MRI over 70 min before radiosurgery planning. Meningiomas were delineated manually in the PET dataset. PET volumes at each time point were compared to the reference standard 60 min post tracer injection (p.i.) using the Friedman test followed by a Wilcoxon signed-rank test and Bonferroni correction. In all patients, the earliest time point with 100% lesion detection compared to 60 min p.i. was identified. PET volumes did not change significantly from 15 min p.i. (p = 1.0) compared to 60 min p.i. The earliest time point with 100% lesion detection in all patients was 10 min p.i. In patients with meningiomas undergoing Ga-68-DOTATOC-PET, the tracer uptake time can safely be reduced to 15 min p.i. with comparable PET volume and 100% lesion detection compared to 60 min p.i.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...