Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 5(4): 1217-32, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24761302

RESUMO

We present the assessment of ex vivo mouse muscle tissue by quantitative parametric imaging of the near-infrared attenuation coefficient µt using optical coherence tomography. The resulting values of the local total attenuation coefficient µt (mean ± standard error) from necrotic lesions in the dystrophic skeletal muscle tissue of mdx mice are higher (9.6 ± 0.3 mm(-1)) than regions from the same tissue containing only necrotic myofibers (7.0 ± 0.6 mm(-1)), and significantly higher than values from intact myofibers, whether from an adjacent region of the same sample (4.8 ± 0.3 mm(-1)) or from healthy tissue of the wild-type C57 mouse (3.9 ± 0.2 mm(-1)) used as a control. Our results suggest that the attenuation coefficient could be used as a quantitative means to identify necrotic lesions and assess skeletal muscle tissue in mouse models of human Duchenne muscular dystrophy.

2.
J Appl Physiol (1985) ; 115(9): 1393-401, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23990241

RESUMO

Minimally invasive, high-resolution imaging of muscle necrosis has the potential to aid in the assessment of diseases such as Duchenne muscular dystrophy. Undamaged muscle tissue possesses high levels of optical birefringence due to its anisotropic ultrastructure, and this birefringence decreases when the tissue undergoes necrosis. In this study, we present a novel technique to image muscle necrosis using polarization-sensitive optical coherence tomography (PS-OCT). From PS-OCT scans, our technique is able to quantify the birefringence in muscle tissue, generating an image indicative of the tissue ultrastructure, with areas of abnormally low birefringence indicating necrosis. The technique is demonstrated on excised skeletal muscles from exercised dystrophic mdx mice and control C57BL/10ScSn mice with the resulting images validated against colocated histological sections. The technique additionally gives a measure of the proportion (volume fraction) of necrotic tissue within the three-dimensional imaging field of view. The percentage necrosis assessed by this technique is compared against the percentage necrosis obtained from manual assessment of histological sections, and the difference between the two methods is found to be comparable to the interobserver variability of the histological assessment. This is the first published demonstration of PS-OCT to provide automated assessment of muscle necrosis.


Assuntos
Músculo Esquelético/patologia , Distrofia Muscular de Duchenne/patologia , Tomografia de Coerência Óptica/métodos , Animais , Modelos Animais de Doenças , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos mdx
3.
Biomed Opt Express ; 3(2): 366-79, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22312589

RESUMO

We report the use of optical coherence tomography (OCT) to determine spatially localized optical attenuation coefficients of human axillary lymph nodes and their use to generate parametric images of lymphoid tissue. 3D-OCT images were obtained from excised lymph nodes and optical attenuation coefficients were extracted assuming a single scattering model of OCT. We present the measured attenuation coefficients for several tissue regions in benign and reactive lymph nodes, as identified by histopathology. We show parametric images of the measured attenuation coefficients as well as segmented images of tissue type based on thresholding of the attenuation coefficient values. Comparison to histology demonstrates the enhancement of contrast in parametric images relative to OCT images. This enhancement is a step towards the use of OCT for in situ assessment of lymph nodes.

4.
J Biomed Opt ; 16(7): 076013, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806274

RESUMO

Three-dimensional optical coherence tomography (3D-OCT) was used to image the structure and pathology of skeletal muscle tissue from the treadmill-exercised mdx mouse model of human Duchenne muscular dystrophy. Optical coherence tomography (OCT) images of excised muscle samples were compared with co-registered hematoxylin and eosin-stained and Evans blue dye fluorescence histology. We show, for the first time, structural 3D-OCT images of skeletal muscle dystropathology well correlated with co-located histology. OCT could identify morphological features of interest and necrotic lesions within the muscle tissue samples based on intrinsic optical contrast. These findings demonstrate the utility of 3D-OCT for the evaluation of small-animal skeletal muscle morphology and pathology, particularly for studies of mouse models of muscular dystrophy.


Assuntos
Distrofia Muscular de Duchenne/patologia , Tomografia de Coerência Óptica/métodos , Animais , Corantes , Modelos Animais de Doenças , Azul Evans , Humanos , Imageamento Tridimensional , Masculino , Camundongos , Camundongos Endogâmicos mdx , Músculo Esquelético/patologia , Necrose , Tomografia de Coerência Óptica/instrumentação
5.
J Biomed Opt ; 13(1): 011003, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18315352

RESUMO

Three-dimensional optical coherence tomography (3D-OCT) is used to evaluate the structure and pathology of regenerating mouse skeletal muscle autografts for the first time. The death of myofibers with associated inflammation and subsequent new muscle formation in this graft model represents key features of necrosis and inflammation in the human disease Duchenne muscular dystrophy. We perform 3D-OCT imaging of excised autografts and compare OCT images with coregistered histology. The OCT images readily distinguish the necrotic and inflammatory tissue of the graft from the intact healthy muscle fibers in the underlying host tissue. These preliminary findings suggest that, with further development, 3D-OCT could be used as a tool for the evaluation of small-animal muscle morphology and pathology, in particular, for analysis of mouse models of muscular dystrophy.


Assuntos
Modelos Animais de Doenças , Rejeição de Enxerto/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Músculo Esquelético/patologia , Músculo Esquelético/transplante , Distrofias Musculares/patologia , Algoritmos , Animais , Estudos de Viabilidade , Feminino , Rejeição de Enxerto/etiologia , Aumento da Imagem/métodos , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...