Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 71: 411-418, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32891744

RESUMO

INTRODUCTION: An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite®-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite® when compared with commercially available 3Mensio Vascular® and Siemens Syngo.via®. METHODS: CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite®, 3 using 3Mensio Vascular®, and 1 using Siemens Syngo.via®. For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared. RESULTS: Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite® (568 sec) when compared with 3Mensio Vascular® (603 sec) or Siemens Syngo.via® (659 sec) with a P-value of 0.88. CONCLUSIONS: The authors conclude that Osirix Lite® is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular® and Siemens Syngo.via®.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Aortografia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Tomada de Decisão Clínica , Procedimentos Endovasculares/efeitos adversos , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...