Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transplantation ; 101(6): 1206-1214, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27306532

RESUMO

BACKGROUND: Solid-phase assays to distinguish complement binding from noncomplement binding HLA-specific antibodies have been introduced, but technical limitations may compromise their interpretation. We have examined the extent to which C1q-binding to HLA-class I single-antigen beads (SAB) is influenced by denatured HLA on SAB, antibody titre, and complement interference that causes a misleading low assessment of HLA-specific antibody levels. METHODS: Sera from 25 highly sensitized patients were tested using Luminex IgG-SAB and C1q-SAB assays. Sera were tested undiluted, at 1:20 dilution to detect high-level IgG, and after ethylene diamine tetraacetic acid treatment to obviate complement interference. Conformational HLA and denatured HLA protein levels on SAB were determined using W6/32 and HC-10 monoclonal antibodies, respectively. Denatured HLA was expressed as HC-10 binding to untreated SAB as a percentage of maximal binding to acid-treated SAB. RESULTS: For undiluted sera, Luminex mean fluorescence intensity (MFI) values for IgG-SAB and C1q-SAB correlated poorly (r = 0.42). ethylene diamine tetraacetic acid and serum dilution improved the correlation (r = 0.57 and 0.77, respectively). Increasing levels of denatured HLA interfered with the detection of C1q binding. Consequently, the correlation between IgG-SAB MFI and C1q-SAB MFI was lowest using undiluted sera and SAB with greater than 30% denatured HLA (r = 0.40) and highest using diluted sera and SAB with 30% or less denatured HLA (r = 0.86). CONCLUSIONS: Antibody level, complement interference, and denatured HLA class I on SAB may all affect the clinical interpretation of the C1q-SAB assay. The C1q-SAB assay represents a substantial additional cost for routine clinical use, and we question its justification given the potential uncertainty about its interpretation.


Assuntos
Ativação do Complemento , Complemento C1q/imunologia , Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Histocompatibilidade , Imunoglobulina G/imunologia , Isoanticorpos/imunologia , Adulto , Especificidade de Anticorpos , Feminino , Rejeição de Enxerto/sangue , Rejeição de Enxerto/imunologia , Sobrevivência de Enxerto , Antígenos HLA/química , Humanos , Imunoglobulina G/sangue , Isoanticorpos/sangue , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Ligação Proteica , Desnaturação Proteica , Dobramento de Proteína , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...