Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurooncol ; 132(2): 307-312, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28120301

RESUMO

Frameless, surface imaging guided radiosurgery (SIG-RS) is a novel platform for stereotactic radiosurgery (SRS) wherein patient positioning is monitored in real-time through infra-red camera tracking of facial topography. Here we describe our initial clinical experience with SIG-RS for the treatment of benign neoplasms of the skull base. We identified 48 patients with benign skull base tumors consecutively treated with SIG-RS at a single institution between 2009 and 2011. Patients were diagnosed with meningioma (n = 22), vestibular schwannoma (n = 20), or nonfunctional pituitary adenoma (n = 6). Local control and treatment-related toxicity were retrospectively assessed. Median follow-up was 65 months (range 61-72 months). Prescription doses were 12-13 Gy in a single fraction (n = 18), 8 Gy × 3 fractions (n = 6), and 5 Gy × 5 fractions (n = 24). Actuarial tumor control rate at 5 years was 98%. No grade ≥3 treatment-related toxicity was observed. Grade ≤2 toxicity was associated with symptomatic lesions (p = 0.049) and single fraction treatment (p = 0.005). SIG-RS for benign skull base tumors produces clinical outcomes comparable to conventional frame-based SRS techniques while enhancing patient comfort.


Assuntos
Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Neoplasias da Base do Crânio/diagnóstico por imagem , Neoplasias da Base do Crânio/radioterapia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias da Base do Crânio/classificação
2.
Neurosurgery ; 77(2): 233-40; discussion 240, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25856109

RESUMO

BACKGROUND: Stereotactic radiosurgery (SRS) is a well-accepted treatment for patients with intracranial metastases, but outcomes with volumetric modulated arc radiosurgery (VMAR) are poorly described. OBJECTIVE: To report our initial clinical experience applying a novel single-isocenter technique to frameless VMAR for simultaneous treatment of multiple intracranial metastases. METHODS: We performed a retrospective analysis of 15 patients undergoing frameless VMAR for multiple intracranial metastases using a single, centrally located isocenter in the period 2009 and 2011. Of these, 3 patients were treated for progressive or recurrent intracranial disease. A total of 62 metastases (median, 3 per patient; range, 2-13) were treated to a median dose of 20 Gy (range, 15-30 Gy). Three patients were treated with fractionated SRS. Follow-up including clinical examination and magnetic resonance imaging (MRI) occurred every 3 months. RESULTS: The median follow-up for all patients was 7.1 months (range, 1.1-24.3), with 11 patients (73.3%) followed until death. For the remaining 4 patients alive at the time of analysis, the median follow-up was 19.6 months (range, 9.2-24.3). Local control at 6 and 12 months was 91.7% (95% confidence interval [CI], 84.6%-100.0%) and 81.5% (95% CI, 67.9%-100.0%), respectively. Regional failure was observed in 9 patients (60.0%), and 7 patients (46.7%) received salvage therapy. Overall survival at 6 months was 60.0% (95% CI, 40.3%-88.2%). Grade 3 or higher treatment-related toxicity was not observed. The median total treatment time was 7.2 minutes (range, 2.8-13.2 minutes). CONCLUSION: Single-isocenter, frameless VMAR for multiple intracranial metastases is a promising technique that may provide similar clinical outcomes compared with conventional radiosurgery.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Radiometria , Radiocirurgia/efeitos adversos , Estudos Retrospectivos , Terapia de Salvação , Análise de Sobrevida , Falha de Tratamento , Resultado do Tratamento
3.
Transl Cancer Res ; 3(4): 383-390, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25821723

RESUMO

PURPOSE: Stereotactic radiosurgery (SRS) is well accepted treatment for patients with intracranial metastases, but the role of frameless radiosurgery is not well defined. Here, we describe our clinical experience applying a novel single-isocenter technique to frameless intensity modulated stereotactic radiosurgery (IMRS) for simultaneous treatment of multiple intracranial metastases. METHODS AND MATERIALS: Between 2006 and 2012, 100 consecutive patients received frameless IMRS for multiple intracranial metastases using a single, centrally-located isocenter. Among these, 29 patients were treated for progressive or recurrent intracranial disease. A total of 465 metastases (median, 4 per patient, range, 2-18) were treated to a median dose of 20 Gy (range, 15-50 Gy). Follow-up including clinical examination and magnetic resonance imaging (MRI) occurred every 3 months. RESULTS: Median follow-up for all patients was 4.3 months (range, 0.2-58.3 months), with 83 patients (83.0%) followed until their death. For the remaining 17 patients alive at the time of analysis, median follow-up was 9.2 months (range, 2.2-58.3 months). Overall survival at 6 months was 49.5% [95% confidence interval (CI), 35.3-63.6%]. Local control at 6 and 12 months was 88.9% (95% CI, 79.1-98.6%) and 81.5% (95% CI, 65.2-97.7%), respectively. Regional failure was observed in 39 patients (39%), and 25 patients (25%) received salvage therapy. Grade 3 or greater treatment-related toxicity was observed in 4 patients (4%) and included intracranial hemorrhage, seizure, and radionecrosis. Median total treatment time was 17.2 minutes (range, 2.8-55.3 minutes). CONCLUSIONS: Single-isocenter IMRS for multiple intracranial metastases can produce clinical outcomes comparable to those of conventional radiosurgery techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...