1.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549258

RESUMO

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Assuntos
Primidona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Primidona/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Limite de Detecção , Anticonvulsivantes/sangue , Espectrometria de Massa com Cromatografia Líquida
2.
Clin Chem Lab Med ; 62(7): 1339-1351, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38515344

RESUMO

OBJECTIVES: A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS: To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS: The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 µg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS: In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.


Assuntos
Carbamazepina , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Carbamazepina/sangue , Carbamazepina/análogos & derivados , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
3.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38407268

RESUMO

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Assuntos
Fenobarbital , Espectrometria de Massas em Tandem , Humanos , Fenobarbital/sangue , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Anticonvulsivantes/sangue , Padrões de Referência , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
4.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37466369

RESUMO

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Topiramato , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Anticonvulsivantes , Isótopos , Padrões de Referência
5.
Clin Chem Lab Med ; 61(11): 1967-1977, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37011038

RESUMO

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based candidate reference measurement procedure (RMP) for levetiracetam quantification in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance spectroscopy (qNMR) was used to characterize the RMP material to ensure traceability to SI units. To quantify levetiracetam, an LC-MS/MS method was optimized using a C8 column for chromatographic separation following protein-precipitation-based sample preparation. Spiked matrix samples of serum and plasma were used to test selectivity and specificity. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Precision and accuracy were evaluated over 5 days. Measurement uncertainty was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of levetiracetam within the range of 1.53-90.0 µg/mL. Intermediate precision was <2.2% and repeatability was 1.1-1.7% across all concentrations. The relative mean bias ranged from -2.5% to -0.3% across all levels and matrices within the measuring range. Diluted samples were found with a mean bias ranging from -0.1 to 2.9%. The predefined acceptance criterion for measurement uncertainty was met and determined for individual measurements independently of the concentration level and sample type to be ≤4.0% (k=2). CONCLUSIONS: We present a novel LC-MS/MS)-based candidate RMP for levetiracetam in human serum and plasma. Its expanded measurement uncertainty of ≤4.0% meets the clinical needs in levetiracetam monitoring. Utilizing qNMR to characterize levetiracetam reference materials allowed metrological traceability to SI units.


Assuntos
Isótopos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Levetiracetam , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...