1.
J Anal Toxicol ; 34(3): 122-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20406535

RESUMO

A high-throughput method has been developed for determining Lewisite [dichloro(2-chlorovinyl)arsine] exposure by measuring the urine metabolite 2-chlorovinylarsonous acid (CVAA) and the oxidized metabolite 2-chlorovinylarsonic acid (CVAOA). The rapid sample preparation included a simple dilution of 400 microL of urine with 40 microL of water and 1 mL of buffer containing an internal standard and brief centrifugation prior to analysis by high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (ICP-MS). CVAOA and CVAA were eluted isocratically with retention factors of approximately 3.0 and 4.2, respectively, from a reversed-phase polar embedded column with a cycle time of 5 min per sample. The dynamic reaction cell, typically used to remove polyatomic isobaric interferences, was not required for ICP-MS analysis because of the resolution of chloride from arsenical peaks of interest. This method was used to detect CVAA and CVAOA in the urine of a rat administered Lewisite up to 24 h after exposure. The method demonstrated linearity over at least three orders of magnitude and had a method detection limit of 1.3 microg/L as CVAA (1.4 microg/L CVAOA). The relative standard deviations for quality control samples ranged from 3 to 6%. The method was sensitive and selective with no false positives in 100 different urine samples collected from individuals with no known exposure to Lewisite. Ninety-six samples could be analyzed in an 8-h day.


Assuntos
Arsenicais/urina , Espectrometria de Massas/métodos , Animais , Arsenicais/metabolismo , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Exposição Ambiental/análise , Humanos , Oxirredução , Ratos , Reprodutibilidade dos Testes
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(15-16): 1045-50, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20356806

RESUMO

The rodenticide monofluoroacetate (MFA) and monochloroacetate (MCA), a chemical intermediate from several chemical syntheses, have been identified as potential agents of chemical terrorism due to their high toxicity. In preparation for response to poisonings and mass exposures, we have developed a quantification method using isotopic dilution to determine MFA and MCA in urine from 50 to 5000 ng/mL. Both analytes were extracted from urine using solid-phase extraction; extraction recoveries were 62% (MFA) and 76% (MCA). The extracts were then separated with isocratic high-performance liquid chromatography and identified using electrospray ionization tandem mass spectrometry, with detection limits of 0.9 and 7.0 ng/mL for MFA and MCA, respectively. Selectivity was established for both analytes with unique chromatographic retention times which were correlated with isotopically labeled internal standards and the use of two mass spectral transitions for each compound. The intra-day variability was less than 5% for both analytes and the inter-day variability was 7% for MFA and 6% for MCA.


Assuntos
Acetatos/urina , Cromatografia Líquida de Alta Pressão/métodos , Fluoracetatos/urina , Rodenticidas/urina , Espectrometria de Massas em Tandem/métodos , Estabilidade de Medicamentos , Humanos , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida
3.
J Am Soc Mass Spectrom ; 18(10): 1821-6, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17719237

RESUMO

A method to enhance the signal intensity and signal-to-noise of several alkyl methylphosphonic acids in negative electrospray ionization liquid chromatography tandem mass spectrometry (ESI LC-MS/MS) is presented. This class of compound represents the initial metabolites and environmental degradants of the nerve agents: VX, rVX (Russian VX), GB (Sarin), GF (Cyclosarin), and GD (Soman). Compared with the post-column addition of the mobile phase, the post-column addition of aprotic solvents and longer chain alcohols enhance the signal intensity and signal-to-noise ratio (S/N) of the chromatographic peaks by factors of up to 60 and 19, respectively. The post-column addition of water, methanol, and ethanol resulted in little or no relative signal enhancement. It is proposed that the post-column addition of these solvents do not result in the same enhancements due to stabilization of analyte solvation through hydrogen bonding.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Compostos Orgânicos/química , Compostos Organofosforados/química , Solventes/química , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Alquilação , Sensibilidade e Especificidade
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 852(1-2): 235-43, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17289448

RESUMO

A sensitive, robust isotope dilution LC/MS/MS method is presented for the quantitative analysis of human urine for the alkyl methylphosphonic acid metabolites of five organophosphorus nerve agents (VX, rVX or VR, GB or Sarin, GD or Soman, and GF or Cyclosarin). The selective sample preparation method employs non-bonded silica solid-phase extraction and is partially automated. While working with a mobile phase composition that enhances the electrospray ionization process, the hydrophilic interaction chromatography method results in a 5-min injection-to-injection cycle time, excellent peak shapes and adequate retention (k'=3.1). These factors lead to limits of detection for these metabolites as low as 30 pg/mL in a 1-mL sample of human urine. The quality control data (15 and 75 ng/mL) demonstrate accurate (-0.5 to +3.4%) and precise (coefficients of variation of 2.1-3.6%) quantitative results over the clinically relevant urine concentration range of 1-200 ng/mL for a validation set of 20 standard and quality control sets prepared by five analysts over 54 days. The selectivity of the method is demonstrated for a 100-individual reference range study, as well as the analysis of relevant biological samples. The combined sample preparation and analysis portions of this method have a throughput of 288 samples per day.


Assuntos
Substâncias para a Guerra Química/análise , Cromatografia Líquida de Alta Pressão/métodos , Compostos Organofosforados/urina , Espectrometria de Massas em Tandem/métodos , Urina/química , Humanos , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
5.
J Chromatogr B Analyt Technol Biomed Life Sci ; 832(2): 292-301, 2006 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-16495163

RESUMO

The prevalence of exposure to volatile organic compounds (VOCs) has raised concern about possible health effects resulting from chronic human exposure. To support studies exploring the relation between VOC exposure and health effects, we developed an automated analytical method using solid-phase microextraction (SPME), capillary gas chromatography (GC), and quadrupole mass spectrometry (MS). This method quantifies trace levels (low parts per trillion) of 14 halogenated alkanes, 5 halogenated alkenes, 10 aromatic compounds, and 2 other VOCs in human blood. Detection limits for the SPME-GC-MS method range from 0.005 to 0.12 microg/L, with linear calibration curves spanning three orders of magnitude. The improved throughput of this method will enable us to expand biomonitoring efforts to assess nonoccupational VOC exposure in large epidemiological studies.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Compostos Orgânicos/sangue , Humanos , Controle de Qualidade , Padrões de Referência , Volatilização