Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Circulation ; 112(9 Suppl): I260-4, 2005 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-16159828

RESUMO

BACKGROUND: Despite growing interest in stent-graft implantation for type-B aortic dissection, there are no established recommendations to prepare and perform an implantation procedure. METHODS AND RESULTS: We directly compared angiography (ANGIO), transesophageal echocardiography (TEE), and intravascular ultrasound (IVUS) intraprocedually before and after placement of 48 stent grafts in 42 consecutive patients (12 women, 61+/-11 years of age) with acute and chronic type-B aortic dissection for both usefulness and capability to guide aortic stent-graft implantation. Both IVUS and TEE are superior to ANGIO to identify multiple entries (52 and 43 versus 34; P<0.005 each), to diagnose false-lumen slow flow after stent-graft implantation (32 and 31 versus 24; P<0.005 each) and to detect incomplete stent apposition (18 and 16 versus 8; P<0.005 each). In comparison with ANGIO, guide wire position over the entire length of the aorta was documented more frequently by TEE and IVUS (40 and 42 versus 25; P<0.001 each). In 4 patients with abdominal extension of the dissection, only IVUS was able to accurately identify the false lumen over the entire length of the diseased aorta. TEE was superior to IVUS and ANGIO in the detection of endoleaks (5 versus 0 and 1; P<0.05 each). Intraprocedural ANGIO, TEE, and IVUS had been performed without complications in all patients. CONCLUSIONS: TEE in conjunction with ANGIO appears to be advantageous and adds incremental information to safely guide stent-graft placement in type-B aortic dissection. Additional use of IVUS was found to be helpful in patients with complex anatomy and abdominal extension of the dissection.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Aortografia , Implante de Prótese Vascular/métodos , Ecocardiografia Transesofagiana , Radiografia Intervencionista , Stents , Ultrassonografia de Intervenção , Idoso , Dissecção Aórtica/classificação , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/classificação , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Abdominal/classificação , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/classificação , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenotereftalatos , Estudos Retrospectivos
3.
Ann Thorac Surg ; 78(2): 686-7, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15276548

RESUMO

Open heart surgery is the standard procedure for closure of ostium secundum atrial septal defects. Recently, percutaneous transcatheter procedures emerged as therapeutic alternatives for closure of both atrial septal defects and patent foramen ovale. Unfortunately, however, such percutaneous procedures may require surgical intervention for early or late complications. We report a case with emergent surgery for dislocation of the Amplatzer septal occluder into the aortic arch diagnosed 30 days after percutaneous closure of an atrial septal defect.


Assuntos
Aorta Torácica/cirurgia , Migração de Corpo Estranho/cirurgia , Comunicação Interatrial/cirurgia , Complicações Pós-Operatórias/cirurgia , Próteses e Implantes/efeitos adversos , Bioprótese , Cateterismo Cardíaco , Ponte Cardiopulmonar , Remoção de Dispositivo , Emergências , Aneurisma Cardíaco/complicações , Aneurisma Cardíaco/cirurgia , Parada Cardíaca Induzida , Comunicação Interatrial/complicações , Humanos , Pericárdio , Reoperação
4.
J Card Surg ; 18(5): 471-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12974938

RESUMO

BACKGROUND: Endovascular stent-graft placement is a new concept for the treatment of aortic dissection and aneurysm. Intravascular ultrasound (IVUS) with established diagnostic features may be instrumental in guiding endovascular procedures. METHODS: We performed IVUS and digital angiography before, during, and after implantation of 47 stent grafts in 40 patients with Stanford type B dissection (26 patients, 28 stent grafts), thoracic aneurysm (9 patients, 11 stent grafts), and abdominal aneurysm (5 patients, 8 stent grafts). RESULTS: IVUS could clearly identify the aortic anatomy and differentiate between true and false lumen in all cases of dissection. In four patients with type B dissection extending from the thoracic to the abdominal aorta the true lumen was exclusively identified by IVUS, and thus, essential for safe execution of the procedure. In another patient stent-graft placement in the aorta was optimized by covering a second entry detected by IVUS, but undetected by angiography. The site of stent implantation, the true and false lumen, as well as entry and reentry were always identified in both thoracic and abdominal aorta. In comparison with angiography, IVUS information led to additional balloon molding due to incomplete stent apposition in seven cases. CONCLUSIONS: As an adjunctive imaging modality IVUS is likely to improve stent-graft placement in aortic type B dissection, especially in patients with abdominal extension.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...