Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Dtsch Med Wochenschr ; 139(16): 829-34, 2014 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-24722932

RESUMO

BACKGROUND: Remote Patient Management for chronic heart failure (CHF) is gaining increasing importance in health care. Telemonitoring is defined as daily measuring of health parameters by the patient and their transmission to a telemedical centre. The adherence of this action by the patient can be considered as a measure for RPM adoption. METHODS: The randomized controlled clinical trial TIM-HF (NCT 00543881) was conducted between 2008 and 2010 with 710 CHF patients with the primary endpoint total mortality for a mean follow-up of 21.5 ± 7.2 months. The non-prespecified analysis of adherence to daily measuring of ECG, blood pressure, weight and self-assessment was focused on sociodemographic and disease-related factors of the 354 RPM patients. RESULTS: The mean adherence to telemonitoring was more than 80% (absolute adherence: 81.8 ± 22.8%, relative adherence: 88.9 ± 21.5%). From the beginning of treatment 6.5% of the patients (23/354) have shown an adherence below average. The high adherence of the majority of the patients was stable for the entire study duration and irrespective of age, sex, severity of the disease and the presence of mild to moderate depression. CONCLUSION: A high adherence can be achieved by individual training of the patient regarding the handling of his disease, the use of telemedical devices and an easy-to-use telemonitoring system. The majority of the informed self-determined CHF patients NYHA class II/III are adopting telemonitoring and are adherent in the long term.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Consulta Remota/estatística & dados numéricos , Telemetria/estatística & dados numéricos , Idoso , Monitorização Ambulatorial da Pressão Arterial/psicologia , Peso Corporal , Eletrocardiografia , Feminino , Alemanha , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Cooperação do Paciente/psicologia , Cooperação do Paciente/estatística & dados numéricos , Pacientes Desistentes do Tratamento/estatística & dados numéricos , Telemetria/psicologia , Revisão da Utilização de Recursos de Saúde/estatística & dados numéricos
2.
Small ; 9(23): 4000-5, 2013 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-23670861

RESUMO

Immunoassays are used for detecting protein targets for various applications. Here, a modification of immunoassays to allow a purely electrical detection of the target protein concentration is shown. The modification comprises a ß-D-glucosidase as reporter enzyme and a cyanogenic glycoside as substrate. The enzymatic reaction produces cyanide in small quantities. For electrical detection of the cyanide, a novel sensor is developed, based on a gold micro wire. The cyanide dissolves the gold wire and changes the electrical resistance of the wire. Monitoring the resistance change allows a quantitative measurement of the target human C-reactive protein (an inflammatory marker) in blood plasma in the physiological relevant concentration range.


Assuntos
Glucosidases/química , Glucosidases/metabolismo , Ouro/química , Imunoensaio/instrumentação , Imunoensaio/métodos , Proteína C-Reativa/análise , Glicosídeos/metabolismo , Humanos
3.
Nanotechnology ; 20(48): 485302, 2009 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-19880975

RESUMO

Two-particle colloids containing nanomagnets and microscale mirrors can be prepared from iron oxide nanoparticles, microscale metal flakes and high-density liquids stabilizing the mirror suspension against sedimentation by matching the constituent's density. The free Brownian rotation of the micromirrors can be magnetically controlled through an anisotropic change in impulse transport arising from impacts of the magnetic nanoparticles onto the anisotropic flakes. The resulting rapid mirror orientation allows large changes in light transmission and switchable optical reflectivity. The preparation of a passive display was conceptually demonstrated through colloid confinement in a planar cavity over an array of individually addressable solenoids and resulted in 4 x 4 digit displays with a reaction time of less than 100 ms.


Assuntos
Cristais Líquidos/química , Magnetismo , Nanopartículas/química , Fenômenos Ópticos , Suspensões/química , Fenômenos Mecânicos , Modelos Químicos
5.
Gastrointest Radiol ; 5(2): 155-60, 1980 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-7380158

RESUMO

Differentiation of normal bowel loops from pathologic process by computed tomography is often difficult. Techniques are described for opacification of bowel loops via oral, rectal, and colostomy administration of contrast material. Examples of abdominal and pelvic pseudotumors which were proven not to be pathologic lesions are presented. By following simple techniques of bowel marking, one can avoid false positive diagnoses.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Intestinais/diagnóstico por imagem , Tecnologia Radiológica , Tomografia Computadorizada por Raios X , Idoso , Criança , Disgerminoma/diagnóstico por imagem , Reações Falso-Positivas , Feminino , Humanos , Lactente , Intestinos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...