Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dent Mater ; 40(2): 198-209, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37951752

RESUMO

OBJECTIVES: To investigate the 5-year intraoral evolution and kinetics of low-temperature degradation (LTD) of second-generation monolithic prostheses made of 3% molar yttrium-doped tetragonal zirconia polycrystal (3Y-TZP) and the influence of masticatory mechanical stresses and glaze layer on this evolution. METHODS: A total of 101 posterior tooth elements were included in this prospective clinical study, which comprised ex vivo LTD monitoring (at baseline, 6 months, 1 year, 2 years, 3 years, and 5 years) using Raman spectroscopy (n = 2640 monoclinic phase measurement points per evaluation time) and scanning electron microscopy (SEM). Four types of areas (1-2 mm2 surface, six on molars, and four on premolars) were analysed on each element surface: occlusal, axial, glazed, or unglazed. Raman mapping, high-resolution SEM, and focused ion beam-SEM were performed on selected samples. RESULTS: The dental prostheses developed a tetragonal-to-monoclinic transformation at the extreme surface of the material after six months in a buccal environment, and this process increased significantly over time. Over the five years of monitoring, the transformation developed nonuniformly with the presence of localised clusters of monoclinic grains. Tribological stresses generate grain pull-out from these clusters, which may raise questions regarding the release of 3Y-TZP nanoparticles into the body. The prosthesis fracture rate was 4.5% after 5 years. SIGNIFICANCE: LTD developed in vivo on the surfaces of 3Y-TZP dental prostheses and progressed slowly but significantly over time, up to 5 years investigation. However, the effects of aging on the failure rate recorded and of zirconia nanoparticles released into the body require further investigation.


Assuntos
Prótese Dentária , Zircônio , Temperatura , Estudos Prospectivos , Propriedades de Superfície , Zircônio/química , Ítrio/química , Teste de Materiais , Materiais Dentários/química , Cerâmica/química
3.
Dent Mater ; 37(7): 1134-1149, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33858665

RESUMO

OBJECTIVE: To investigate the intraoral development and kinetics of low-temperature degradation (LTD) in second-generation 3 mol.% yttria-doped tetragonal zirconia polycrystal (3Y-TZP) monolithic prostheses, as well as the influence of masticatory mechanical stress and glaze layer on it. METHODS: A total of 101 posterior tooth elements were included in a prospective clinical study, which included ex vivo LTD monitoring (at baseline, 6 months, 1 year, and 2 years) using Raman spectroscopy (n = 2640 monoclinic phase measurement points per evaluation time) and SEM. Four types of areas (1-2 mm2 surface, 6 on molars, and 4 on premolars) were analyzed on each element surface: occlusal, axial, glazed, or unglazed. Raman depth mapping and high-resolution SEM were performed on the selected samples. RESULTS: LTD developed in 3Y-TZP monolithic restorations 6 months after intraoral placement and progressed with time. After two years, the tetragonal-to-monoclinic transformation was non-uniform, with the presence of localized clusters of transformed grains. In axial areas, the grain aspect was typical of the classical nucleation-growth process reported for LTD, which progresses from the surface to a depth of several tens of microns. However, in occlusal areas, tribological stress generated surface crushing and grain pull-out from the clusters, which induced an underestimation of the aging process when the evaluation was limited to monoclinic phase quantification. Glazing cannot be considered a protection against LTD. SIGNIFICANCE: If LTD occurs in dental prostheses in the same way as in orthopedic prostheses, its clinical impact is unknown and needs to be further studied.


Assuntos
Prótese Dentária , Zircônio , Cerâmica , Materiais Dentários , Teste de Materiais , Estudos Prospectivos , Propriedades de Superfície , Temperatura , Ítrio
4.
J Dent ; 91: 103229, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31722238

RESUMO

OBJECTIVES: This study aimed to investigate (1) clinical outcomes of second-generation zirconia restorations, including patients with bruxism clinical signs, and (2) the material wear process. METHODS: A total of 95 posterior monolithic zirconia tooth-elements in 45 patients were evaluated, 85 on implants and 10 on natural teeth, and 20.3% of restorations being fixed partial dentures (FPDs). Occlusal contact point areas were determined and half of those areas were left unglazed and just polished. Restorations were clinically evaluated following criteria of the World Dental Federation and antagonistic teeth were examined at each evaluation time. Wear ex vivo analyses using SEM and 3D laser profilometry were performed at baseline and after 6 months, 1 year, and 2 years respectively, temporarily removing the prostheses. RESULTS: The Kaplan-Meier survival rate of restorations was 93.3% (100% for FPDs) and the success rate was 81.8%, with 4 abutment debondings, 3 tooth-supported crown debondings (provisional cement use), 1 restoration fracture, 1 minor chipping, 1 core fracture, 1 root fracture, and 2 implant losses. 80% of catastrophic failures occurred in patients with clinical signs of bruxism (61.7% of patients). Complications were also observed on antagonistic teeth (3 catastrophic failures). Clinical evaluation of the restorations showed good results from the aesthetic, functional, and biological perspective. Zirconia wear was inferior to 15 µm, while glaze wear was observed on all occlusal contact areas after 1 year. CONCLUSIONS: Monolithic zirconia FPDs are promising but the failure rate of single-unit restorations was not as high as expected in this sample including patients with bruxism clinical signs. CLINICAL SIGNIFICANCE: Within study limitations, FPDs showed excellent short-term results but further research is needed for single-unit restorations considering samples, which do not exclude bruxers. The weak link is the restoration support or the antagonist tooth, one hypothesis being that zirconia stiffness and lack of resilience do not promote occlusal stress damping.


Assuntos
Bruxismo , Coroas , Prótese Dentária Fixada por Implante , Restauração Dentária Permanente , Prótese Parcial Fixa , Zircônio , Falha de Restauração Dentária , Humanos , Estudos Prospectivos
5.
Dent Mater ; 34(6): 825-850, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29627079

RESUMO

OBJECTIVES: This study aims to systematically review the different methods used for wear measurement of dental tissues and materials in clinical studies, their relevance and reliability in terms of accuracy and precision, and the performance of the different steps of the workflow taken independently. METHODS: An exhaustive search of clinical studies related to wear of dental tissues and materials reporting a quantitative measurement method was conducted. MedLine, Embase, Scopus, Cochrane Library and Web of Science databases were used. Prospective studies, pilot studies and case series (>10 patients), as long as they contained a description of wear measurement methodology. Only studies published after 1995 were considered. RESULTS: After duplicates' removal, 495 studies were identified, and 41 remained for quantitative analysis. Thirty-four described wear-measurement protocols, using digital profilometry and superimposition, whereas 7 used alternative protocols. A specific form was designed to analyze the risk of bias. The methods were described in terms of material analyzed; study design; device used for surface acquisition; matching software details and settings; type of analysis (vertical height-loss measurement vs volume loss measurement); type of area investigated (entire occlusal area or selective areas); and results. SINIFICANCE: There is a need of standardization of clinical wear measurement. Current methods exhibit accuracy, which is not sufficient to monitor wear of restorative materials and tooth tissues. Their performance could be improved, notably limiting the use of replicas, using standardized calibration procedures and positive controls, optimizing the settings of scanners and matching softwares, and taking into account unusable data.


Assuntos
Materiais Dentários/química , Desgaste de Restauração Dentária , Desgaste dos Dentes , Humanos , Teste de Materiais , Propriedades de Superfície
6.
Appl Ergon ; 54: 196-204, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26851479

RESUMO

Innovative in-car applications provided on smartphones can deliver real-time alternative mobility choices and subsequently generate visual-manual demand. Prior studies have found that multi-touch gestures such as kinetic scrolling are problematic in this respect. In this study we evaluate three prototype tasks which can be found in common mobile interaction use-cases. In a repeated-measures design, 29 participants interacted with the prototypes in a car-following task within a driving simulator environment. Task completion, driving performance and eye gaze have been analysed. We found that the slider widget used in the filtering task was too demanding and led to poor performance, while kinetic scrolling generated a comparable amount of visual distraction despite it requiring a lower degree of finger pointing accuracy. We discuss how to improve continuous list browsing in a dual-task context.


Assuntos
Atenção , Condução de Veículo , Aplicativos Móveis , Smartphone , Interface Usuário-Computador , Adulto , Comportamento de Escolha , Apresentação de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise e Desempenho de Tarefas , Adulto Jovem
7.
Cell Death Differ ; 23(4): 640-53, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26470725

RESUMO

Integrin α5ß1 expression is correlated with a worse prognosis in high-grade glioma. We previously unraveled a negative crosstalk between integrin α5ß1 and p53 pathway, which was proposed to be part of the resistance of glioblastoma to chemotherapies. The restoration of p53 tumor-suppressor function is under intensive investigations for cancer therapy. However, p53-dependent apoptosis is not always achieved by p53-reactivating compounds such as Nutlin-3a, although full transcriptional activity of p53 could be obtained. Here we investigated whether integrin α5ß1 functional inhibition or repression could sensitize glioma cells to Nutlin-3a-induced p53-dependent apoptosis. We discovered that α5ß1 integrin-specific blocking antibodies or small RGD-like antagonists in association with Nutlin-3a triggered a caspase (Casp) 8/Casp 3-dependent strong apoptosis in glioma cells expressing a functional p53. We deciphered the molecular mechanisms involved and we showed the crucial role of two anti-apoptotic proteins, phosphoprotein enriched in astrocytes 15 (PEA-15) and survivin in glioma cell apoptotic outcome. PEA-15 is under α5ß1 integrin/AKT (protein kinase B) control and survivin is a p53-repressed target. Moreover, interconnections between integrin and p53 pathways were revealed. Indeed PEA-15 repression by specific small-interfering RNA (siRNA)-activated p53 pathway to repress survivin and conversely survivin repression by specific siRNA decreased α5ß1 integrin expression. This pro-apoptotic loop could be generalized to several glioma cell lines, whatever their p53 status, inasmuch PEA-15 and survivin protein levels were decreased. Our findings identify a novel mechanism whereby inhibition of α5ß1 integrin and activation of p53 modulates two anti-apoptotic proteins crucially involved in the apoptotic answer of glioma cells. Importantly, our results suggest that high-grade glioma expressing high level of α5ß1 integrin may benefit from associated therapies including integrin antagonists and repressors of survivin expression.


Assuntos
Glioma/metabolismo , Proteínas Inibidoras de Apoptose/metabolismo , Integrina alfa5beta1/metabolismo , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Fosfoproteínas/metabolismo , Transdução de Sinais , Proteína Supressora de Tumor p53/metabolismo , Apoptose/genética , Proteínas Reguladoras de Apoptose , Astrócitos/metabolismo , Astrócitos/patologia , Linhagem Celular Tumoral , Glioma/genética , Glioma/patologia , Humanos , Proteínas Inibidoras de Apoptose/genética , Integrina alfa5beta1/genética , Peptídeos e Proteínas de Sinalização Intracelular/genética , Fosfoproteínas/genética , Survivina , Proteína Supressora de Tumor p53/genética
8.
Rev Med Liege ; 69 Spec No: 66-71, 2014.
Artigo em Francês | MEDLINE | ID: mdl-25796802

RESUMO

Cohesive fracture of the veneering ceramic (chipping) is the first cause of failure of zirconia-based prostheses on natural teeth and implants. Besides risk factors related to the material (thermal stresses generated during the manufacturing process, framework inappropriate design), there are some clinical risk factors, which can influence the restoration prognosis. Indeed, unfavorable occlusal relationships and/or the presence of parafunctions such as bruxism and clenching, which are frequent pathologies, engender significant overloading. A retrospective study was performed at the University Hospital Center (CHU) of Liege on 147 dental and implants prostheses, placed between May 2003 and January 2012. This study highlighted a significant correlation between chipping and the absence of an occlusal nightguard (p = 0.0048), the presence of a ceramic restoration as an antagonist (p = 0.013), the presence of occlusal parafunctions (p = 0.018), and the presence of implants as support of the restorations (p = 0.026). These results underline the importance of external stress and occlusal risk factors diagnosis, as the need to perform an occlusal nightguard to patients with parafunctions.


Assuntos
Implantes Dentários , Materiais Dentários , Falha de Restauração Dentária , Zircônio , Humanos , Teste de Materiais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco
9.
Todays OR Nurse ; 17(4): 5-11, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7570807

RESUMO

1. Reconstruction of the anterior cruciate ligament may be accomplished in many ways using a variety of autologous as well as allograft tissue. 2. A method of fixation uses an Endobutton for femoral fixation and a 19 mm Hewson Ligament Button for the tibial fixation of the graft. 3. This method of fixation will permit the surgeon to choose the graft best suited to the patient's needs while allowing endoscopic reconstruction of the anterior cruciate ligament, regardless of the choice of graft. Fixation of the graft need no longer be a variable in anterior cruciate ligament reconstruction.


Assuntos
Lesões do Ligamento Cruzado Anterior , Artroscopia/métodos , Transplante Ósseo , Tendões/transplante , Artroscópios , Artroscopia/enfermagem , Humanos , Ferimentos e Lesões/cirurgia
10.
Arthroscopy ; 11(2): 245-51, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7794443

RESUMO

Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.


Assuntos
Meniscos Tibiais/cirurgia , Lesões do Menisco Tibial , Humanos , Métodos , Técnicas de Sutura/instrumentação
11.
Mayo Clin Proc ; 62(7): 595-600, 1987 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3586717

RESUMO

Although previous investigators have attempted to identify platelet crossmatching methods that could be used routinely for pretransfusion testing, such studies have excluded patients with underlying clinical conditions inherently associated with low corrected platelet increments. Because many refractory hematologic patients have such underlying conditions, we decided to assess the usefulness of platelet crossmatching (in addition to HLA matching) in determining the posttransfusion corrected platelet count increment in eight medically complicated patients who received a total of 35 single-donor platelet transfusions. In this limited study, the predictive value of a negative crossmatch was only 55%, whereas that of a positive crossmatch was 88%. The test used had a sensitivity of 65% and a specificity of 83%. The results of our study suggest that platelet crossmatching may be a useful additional study for predicting the outcome of transfusion--even in medically complex cases--if it can be done rapidly and relatively inexpensively.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas , Plaquetas/análise , Doenças Hematológicas/sangue , Adulto , Idoso , Transfusão de Sangue , Feminino , Teste de Histocompatibilidade , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Valor Preditivo dos Testes
12.
Gerodontics ; 2(4): 127-30, 1986 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3462076
13.
Z Naturforsch C Biosci ; 35(11-12): 1012-8, 1980.
Artigo em Inglês | MEDLINE | ID: mdl-6451993

RESUMO

Calcium binding sites having low affinity constants of less than 10(3) M-1 were titrated in native sarcomplasmic reticulum vesicles as well as in lipid deprived membranes and in the isolated calcium transport ATPase. Short time calcium binding measurements and the determination of the calcium binding heat allow to distinguish low affinity calcium binding sites located on the external surface of th sarcoplasmic reticulum membranes from those present in the section of the transport molecule directed to the vesicular space. The same number of internal binding sites was found for preparations deprived of their lipid content as well as of preparations depleted of their lipids and of their accessorial proteins. Magnesium interferes with calcium binding to the external as well as to the internal low affinity calcium binding sites. The implications of the existence of the low affinity calcium binding sites in the internal section of the calcium transport ATPase are discussed.


Assuntos
ATPases Transportadoras de Cálcio/metabolismo , Cálcio/metabolismo , Membranas Intracelulares/enzimologia , Retículo Sarcoplasmático/enzimologia , Animais , Sítios de Ligação , Transporte Biológico Ativo , Cinética , Magnésio/farmacologia , Músculos/enzimologia , Ligação Proteica , Coelhos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...