1.
Phys Rev E ; 106(5-2): 055208, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36559450

RESUMO

We establish multicomponent 1+ injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density n_{e}, average electron energy 〈E_{e}〉, and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the n_{e}, 〈E_{e}〉 ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The 〈E_{e}〉 and n_{e} of a hydrogen discharge are found to be 600_{-300}^{+600}eV and 8_{-3}^{+8}×10^{11}cm^{-3}, respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms-10 ms.

2.
Rev Sci Instrum ; 93(1): 013302, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35104948

RESUMO

The performance of a minimum-B Electron Cyclotron Resonance Ion Source (ECRIS) is traditionally quantified by measuring the beam current and quality of the extracted ion beams of different charge state ions. The stability of the extracted ion beam currents has drawn more attention recently as the technology is pushing its limits toward higher ion charge states and beam intensities. The stability of the extracted beam is often compromised by plasma instabilities manifesting themselves as rapid oscillations of the beam currents in millisecond scale. This paper focuses on practical aspects of diagnostics techniques of the instabilities, showcases examples of instability-related diagnostics signals, and links them to the plasma physics of ECR ion sources. The reviewed techniques include time-resolved microwave emission diagnostics, bremsstrahlung measurements, direct measurement of electron and ion fluxes, measurement of the ion beam energy spread, and optical emission diagnostics. We list the advantages and disadvantages of each technique and outline the development needs of further diagnostics. Finally, we discuss the implications of the instabilities in both historical and forward-looking context of ECRIS development.

3.
Rev Sci Instrum ; 91(2): 023303, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32113443

RESUMO

An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very strong radial magnetic confinement with Brad = 1.42 T. The commissioning of HIISI began in Fall 2017, and in Spring 2019, it has met the main objectives. As an example, the intensity of the Xe27+ ion beam has improved from 20 µA to 230 µA. In addition, the beam intensity of the Xe44+ ion beam has exceeded the requirement set by the irradiation testing program. The performance of HIISI is comparable to superconducting ECR ion sources with the same maximum microwave frequency of 18 GHz and a total power of 3 kW. For example, Ar16+ and Xe30+ ion beam intensities of 130 µA and 106 µA, respectively, have been obtained with a total microwave power of 3 kW distributed between 18, 17.4, and 14.5 GHz frequencies. The ion beams have been extracted through an 8 mm plasma electrode aperture using 15-17 kV extraction voltage. The latest development work, extracted ion beam intensities, special features, and future prospects of HIISI are presented in this paper.

4.
Rev Sci Instrum ; 91(1): 013502, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012519

RESUMO

Further progress in the development of electron cyclotron resonance (ECR) ion sources (ECRISs) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of the EED in an unstable mode of plasma confinement, i.e., in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences between the EED escaping from stable and unstable plasmas. It was found that nonlinear phenomena alter the EED noticeably. The electron losses are enhanced in both unstable regimes, with two-frequency heating suppressing the instabilities. It has been shown earlier that two-frequency heating boosts the ECRIS performance presumably owing to the suppression of instabilities. We report the observed changes in EED introduced by the secondary frequency in different regimes, including an off-resonance condition, where the secondary frequency is lower than the minimum frequency satisfying the resonance condition for cold electrons at the magnetic field minimum. Finally, we suggest an experimental method of qualitative evaluation of the energy distribution of electrons confined in the magnetic trap using a method of measuring energy distribution of lost electrons during the plasma decay in pulsed operation of the ion source.

5.
Rev Sci Instrum ; 91(1): 013304, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012571

RESUMO

Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms-60 ms with a clear dependence on the ion charge-to-mass ratio-higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used for estimating the extracted RIB production efficiency.

6.
Rev Sci Instrum ; 91(1): 013318, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012583

RESUMO

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction voltage of the ion source is switched off, accompanied by two orders of magnitude decrease in Ar9+ optical emission intensity, suggesting that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions of normal ECRIS operation. The relative changes of the plasma optical emission and the ion beam current have been measured in CW and amplitude modulation operation mode of microwave injection. It is concluded that in the CW mode, the ion currents could be limited by diffusion transport and electrostatic confinement of the ions rather than beam formation in the extraction region and subsequent transport. The high resolution of the spectrometer allows determining the ion temperature by measuring the Doppler broadening of the emission lines and subtracting the wavelength dependent instrumental broadening. The measured ion temperatures in the JYFL 14 GHz ECRIS are between 5 and 28 eV, depending on the plasma species and charge state. Gas mixing is shown to be an effective method to decrease the ion temperature of high charge state argon ions from 20 eV in pure argon discharge to 5 eV when mixed with oxygen.

7.
Rev Sci Instrum ; 90(11): 113321, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779446

RESUMO

The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-generation sources operating at frequencies from 10 to 18 GHz. The development of minimum-B ECR ion sources based on the superposition of solenoid and sextupole fields has long relied on semiempirical scaling laws for the strength of the magnetic field with increasing plasma heating frequency. This approach is becoming increasingly difficult with the looming limits of superconducting technologies being able to satisfy the magnetic field requirements at frequencies approaching 60 GHz. Thus, we discuss alternative ECRIS concepts and proposed modifications to existing sources that are supported by the current understanding derived from the plasma diagnostics experiments.

8.
Rev Sci Instrum ; 90(12): 123303, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893842

RESUMO

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas are prone to kinetic instabilities resulting in loss of electron and ion confinement. It is demonstrated that the biased disk of an ECRIS can be used as a probe to quantify such instability-induced electron and ion losses occurring in less than 10 µs. The qualitative interpretation of the data is supported by the measurement of the energy spread of the extracted ion beams implying a transient plasma potential >1.5 kV during the instability. A parametric study of the electron losses combined with electron tracking simulations allows for estimating the fraction of electrons expelled in each instability event to be on the order of 10% of the total electron population.

9.
Rev Sci Instrum ; 89(4): 043506, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29716347

RESUMO

The results of optical emission spectroscopy experiments probing the cold electron population of a 14 GHz Electron Cyclotron Resonance Ion Source (ECRIS) are reported. The study has been conducted with a high resolution spectrometer and data acquisition setup developed specifically for the diagnostics of weak emission line characteristic to ECRIS plasmas. The optical emission lines of low charge state ions and neutral atoms of neon have been measured and analyzed with the line-ratio method. The aforementioned electron population temperature of the cold electron population (Te < 100 eV) is determined for Maxwell-Boltzmann and Druyvesteyn energy distributions to demonstrate the applicability of the method. The temperature was found to change significantly when the extraction voltage of the ion source is turned on/off. In the case of the Maxwellian distribution, the temperature of the cold electron population is 20 ± 10 eV when the extraction voltage is off and 40 ± 10 eV when it is on. The optical emission measurements revealed that the extraction voltage also affects both neutral and ion densities. Based on the rate coefficient analysis with the aforementioned temperatures, switching the extraction voltage off decreases the rate coefficient of neutral to 1+ ionization to 42% and 1+ to 2+ ionization to 24% of the original. This suggests that switching the extraction voltage on favors ionization to charge states ≥2+ and, thus, the charge state distributions of ECRIS plasmas are probably different with the extraction voltage on/off. It is therefore concluded that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions in normal ECRIS operation.

10.
Environ Res ; 157: 64-70, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28525858

RESUMO

Human exposure to intermediate frequency (IF) fields is increasing due to new applications such as electronic article surveillance systems, wireless power transfer and induction heating cookers. However, limited data is available on effects of IF magnetic fields (MF) on male fertility function. This study was conducted to assess possible effects on fertility indicators from exposure to IF MF. Male C57BL/6J mice were exposed continuously for 5 weeks to 7.5kHz MF at 12 and 120µT. Sperm cells from cauda epididymis were analysed for motility, total sperm counts, and head abnormalities. Motile sperm cells were classified as progressive or non-progressive. Testicular spermatid heads were counted as well. The body weight development and reproductive tissue weights were not affected. No exposure-related differences were observed in sperm counts or sperm head abnormalities. Proportion of non-motile cells was significantly decreased in the 120µT group, and a corresponding increase was seen in the percentage of motile cells (significant in non-progressive motile cells). In conclusion, no adverse effects on fertility indicators were observed. Increased sperm motility is an interesting finding that needs to be confirmed in further studies.


Assuntos
Fertilidade/efeitos da radiação , Campos Magnéticos/efeitos adversos , Contagem de Espermatozoides , Motilidade dos Espermatozoides/efeitos da radiação , Espermatozoides/efeitos da radiação , Animais , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reprodução , Espermatozoides/anormalidades , Fatores de Tempo
11.
Rev Sci Instrum ; 87(9): 093301, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782615

RESUMO

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+-O7+ were recorded at various tuner positions and frequencies in the range of 14.00-14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited "mode-hopping" between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

12.
Rev Sci Instrum ; 87(2): 02A701, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931919

RESUMO

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz A-electron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10-100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime.

13.
Rev Sci Instrum ; 87(2): 02A703, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931921

RESUMO

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of ECRISs.

14.
Rev Sci Instrum ; 87(2): 02A704, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931922

RESUMO

An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H(+), H2(+), and H3(+) ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical factor for transitions between different plasma patterns and ion populations.

15.
Rev Sci Instrum ; 87(2): 02A716, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931934

RESUMO

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)-the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10(13) cm(-3)) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10(-4)-10(-3) mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

16.
Rev Sci Instrum ; 87(2): 02A725, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931943

RESUMO

Several ion source related research and development projects are in progress at the Department of Physics, University of Jyväskylä (JYFL). The work can be divided into investigation of the ion source plasma and development of ion sources, ion beams, and diagnostics. The investigation covers the Electron Cyclotron Resonance Ion Source (ECRIS) plasma instabilities, vacuum ultraviolet (VUV) and visible light emission, photon induced electron emission, and the development of plasma diagnostics. The ion source development covers the work performed for radiofrequency-driven negative ion source, RADIS, beam line upgrade of the JYFL 14 GHz ECRIS, and the development of a new room-temperature-magnet 18 GHz ECRIS, HIISI.

17.
Rev Sci Instrum ; 87(2): 02A729, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931947

RESUMO

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. It was found that even in various gases (helium and oxygen were studied) and at different values of magnetic field and heating power, the dynamic spectra demonstrate common features: decreasing frequency within a single burst as well as from one burst to another.

18.
Rev Sci Instrum ; 87(2): 02B102, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931984

RESUMO

CW 13.56 MHz radio frequency-driven H(-) ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H(-) beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e(-)/H(-) ratio, the new configuration has led to a higher production efficiency of 1 mA H(-) at 1.75 kW RF power. The latest results and upgrade plans are presented.

19.
Rev Sci Instrum ; 87(2): 02B510, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932063

RESUMO

The present paper summarizes the results obtained from the past few years in the framework of the Enhanced Multi-Ionization of short-Lived Isotopes for Eurisol (EMILIE) project. The EMILIE project aims at improving the charge breeding techniques with both Electron Cyclotron Resonance Ion Sources (ECRIS) and Electron Beam Ion Sources (EBISs) for European Radioactive Ion Beam (RIB) facilities. Within EMILIE, an original technique for debunching the beam from EBIS charge breeders is being developed, for making an optimal use of the capabilities of CW post-accelerators of the future facilities. Such a debunching technique should eventually resolve duty cycle and time structure issues which presently complicate the data-acquisition of experiments. The results of the first tests of this technique are reported here. In comparison with charge breeding with an EBIS, the ECRIS technique had lower performance in efficiency and attainable charge state for metallic ion beams and also suffered from issues related to beam contamination. In recent years, improvements have been made which significantly reduce the differences between the two techniques, making ECRIS charge breeding more attractive especially for CW machines producing intense beams. Upgraded versions of the Phoenix charge breeder, originally developed by LPSC, will be used at SPES and GANIL/SPIRAL. These two charge breeders have benefited from studies undertaken within EMILIE, which are also briefly summarized here.

20.
Rev Sci Instrum ; 86(8): 083309, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26329183

RESUMO

The relationship between Balmer-α and Fulcher-band emissions with extracted H(+), H2(+), and H3(+) ions is demonstrated for a 2.45 GHz microwave discharge. Ion mass spectra and optical measurements of Balmer-α and Fulcher-band emissions have been obtained with a Wien Filter having an optical view-port on the plasma chamber axis. The beam of approximately 1 mA is analyzed for different plasma conditions simultaneously with the measurement of light emissions both with temporal resolution. The use of visible light emissions as a valuable diagnostic tool for monitoring the species fraction of the extracted beams is proposed.

SELEÇÃO DE REFERÊNCIAS