Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-34460377

RESUMO

We present a hand functions assessment system (BEAGLE) for kinematic tracking of hand and finger movements, envisioned as a technology-mediated rehabilitation tool. The system is custom-designed for fast and easy placement on an impaired hand (spastic or flaccid), featuring inertial sensors integrated into simple finger caps and a hand strap. An algorithm for a range of motion (ROM) estimation was implemented to provide an objective assessment of hand functions. The efficacy and feasibility of the BEAGLE system were examined in a pilot clinical study performed with ten stroke survivors in the subacute phase. Participants received therapy within two consecutive intensity-matched rehabilitation cycles. The first consisted of conventional therapy, while the second involved a combination of conventional therapy and advanced functional electrical stimulation. Assessments were performed before and after each phase. These included BEAGLE estimates of active voluntary ROM for wrist and various digits, as well as two referent clinical measures for hand functions assessment, Fugl-Meyer and Action Research Arm Test. The results indicate that the ROM assessments can detect change with sensitivity comparable to the standardized clinical scales. Statistically significant changes between the beginning and the end of the second cycle existed in all observed measures, whereas none of these measurements showed a statistically significant improvement in the first therapy cycle. The noted usability metrics indicate that the BEAGLE could be integrated into the rehabilitation workflow in a clinical environment.


Assuntos
Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Fenômenos Biomecânicos , Dedos , Mãos , Humanos , Recuperação de Função Fisiológica , Resultado do Tratamento
2.
Biomed Tech (Berl) ; 64(2): 187-194, 2019 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-29708872

RESUMO

The purpose of this paper is to emphasize the importance of in-air movement besides on-surface movement for handwriting analysis. The proposed method uses a classification of drawing healthy subjects and subjects with Parkinson's disease, according to their on-surface and in-air handwriting parameters during their writing on a graphical tablet. Experimental results on real data sets demonstrate that the highest accuracy of subject's classification was obtained by combining both on-surface and in-air kinematic parameters.


Assuntos
Doença de Parkinson/fisiopatologia , Movimentos do Ar , Escrita Manual , Humanos , Movimento , Doença de Parkinson/diagnóstico
3.
Artif Organs ; 41(11): E166-E177, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29148131

RESUMO

The goal of this study was to investigate surface motor activation zones and their temporal variability using an advanced multi-pad functional electrical stimulation system. With this system motor responses are elicited through concurrent activation of electrode matrix pads collectively termed "virtual electrodes" (VEs) with appropriate stimulation parameters. We observed VEs used to produce selective wrist, finger, and thumb extension movements in 20 therapy sessions of 12 hemiplegic stroke patients. The VEs which produce these three selective movements were created manually on the ergonomic multi-pad electrode by experienced clinicians based on visual inspection of the muscle responses. Individual results indicated that changes in VE configuration were required each session for all patients and that overlap in joint movements was evident between some VEs. However, by analyzing group data, we defined the probability distribution over the electrode surface for the three VEs of interest. Furthermore, through Bayesian logic we obtained preferred stimulation zones that are in accordance with our previously reported heuristically obtained results. We have also analyzed the number of active pads and stimulation amplitudes for these three VEs. Presented results provide a basis for an automated electrode calibration algorithm built on a priori knowledge or the starting point for manual selection of stimulation points.


Assuntos
Terapia por Estimulação Elétrica/métodos , Dedos/inervação , Hemiplegia/reabilitação , Atividade Motora , Reabilitação do Acidente Vascular Cerebral/métodos , Acidente Vascular Cerebral/terapia , Polegar/inervação , Punho/inervação , Adulto , Idoso , Algoritmos , Teorema de Bayes , Fenômenos Biomecânicos , Terapia por Estimulação Elétrica/instrumentação , Desenho de Equipamento , Feminino , Hemiplegia/diagnóstico , Hemiplegia/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Reabilitação do Acidente Vascular Cerebral/instrumentação , Fatores de Tempo , Resultado do Tratamento
4.
IEEE Trans Neural Syst Rehabil Eng ; 25(3): 183-195, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27071179

RESUMO

Providing somatosensory feedback to the user of a myoelectric prosthesis is an important goal since it can improve the utility as well as facilitate the embodiment of the assistive system. Most often, the grasping force was selected as the feedback variable and communicated through one or more individual single channel stimulation units (e.g., electrodes, vibration motors). In the present study, an integrated, compact, multichannel solution comprising an array electrode and a programmable stimulator was presented. Two coding schemes (15 levels), spatial and mixed (spatial and frequency) modulation, were tested in able-bodied subjects, psychometrically and in force control with routine grasping and force tracking using real and simulated prosthesis. The results demonstrated that mixed and spatial coding, although substantially different in psychometric tests, resulted in a similar performance during both force control tasks. Furthermore, the ideal, visual feedback was not better than the tactile feedback in routine grasping. To explain the observed results, a conceptual model was proposed emphasizing that the performance depends on multiple factors, including feedback uncertainty, nature of the task and the reliability of the feedforward control. The study outcomes, specific conclusions and the general model, are relevant for the design of closed-loop myoelectric prostheses utilizing tactile feedback.


Assuntos
Membros Artificiais , Eletromiografia/instrumentação , Retroalimentação Sensorial/fisiologia , Força da Mão/fisiologia , Mãos/fisiologia , Estimulação Física/instrumentação , Tato/fisiologia , Análise de Falha de Equipamento , Humanos , Armazenamento e Recuperação da Informação/métodos , Desenho de Prótese , Análise e Desempenho de Tarefas
5.
Eur J Transl Myol ; 26(2): 6059, 2016 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-27478575

RESUMO

The purpose of this study was to examine surface motor activation zones for wrist, fingers and thumb extension movements and their temporal change during 20 therapy sessions using advanced multi-pad functional electrical stimulation system. Results from four hemiplegic patients indicate that certain zones have higher probability of eliciting each of the target movements. However, mutual overlap and variations of the zones are present not just between the subjects, but also on the intrasubject level, reflected through these session to session transformations of the selected virtual electrodes. The obtained results could be used as a priori knowledge for semi-automated optimization algorithm and could shorten the time required for calibration of the multi-pad electrode.

6.
J Neural Eng ; 13(4): 046014, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27296902

RESUMO

OBJECTIVE: The aim of the present work was to develop and test a flexible electrotactile stimulation system to provide real-time feedback to the prosthesis user. The system requirements were to accommodate the capabilities of advanced multi-DOF myoelectric hand prostheses and transmit the feedback variables (proprioception and force) using intuitive coding, with high resolution and after minimal training. APPROACH: We developed a fully-programmable and integrated electrotactile interface supporting time and space distributed stimulation over custom designed flexible array electrodes. The system implements low-level access to individual stimulation channels as well as a set of high-level mapping functions translating the state of a multi-DoF prosthesis (aperture, grasping force, wrist rotation) into a set of predefined dynamic stimulation profiles. The system was evaluated using discrimination tests employing spatial and frequency coding (10 able-bodied subjects) and dynamic patterns (10 able-bodied and 6 amputee subjects). The outcome measure was the success rate (SR) in discrimination. MAIN RESULTS: The more practical electrode with the common anode configuration performed similarly to the more usual concentric arrangement. The subjects could discriminate six spatial and four frequency levels with SR >90% after a few minutes of training, whereas the performance significantly deteriorated for more levels. The dynamic patterns were intuitive for the subjects, although amputees showed lower SR than able-bodied individuals (86% ± 10% versus 99% ± 3%). SIGNIFICANCE: The tests demonstrated that the system was easy to setup and apply. The design and resolution of the multipad electrode was evaluated. Importantly, the novel dynamic patterns, which were successfully tested, can be superimposed to transmit multiple feedback variables intuitively and simultaneously. This is especially relevant for closing the loop in modern multifunction prostheses. Therefore, the proposed system is convenient for practical applications and can be used to implement sensory perception training and/or closed-loop control of myoelectric prostheses, providing grasping force and proprioceptive feedback.


Assuntos
Simulação por Computador , Próteses Neurais , Tato/fisiologia , Adulto , Amputados , Interfaces Cérebro-Computador , Discriminação Psicológica , Estimulação Elétrica , Feminino , Força da Mão , Humanos , Masculino , Propriocepção , Desenho de Prótese , Psicometria , Punho/inervação , Punho/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...