1.
Opt Express ; 30(24): 43491-43502, 2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36523045

RESUMO

A counter-propagating laser-beam platform using a spherical plasma mirror was developed for the kilojoule-class petawatt LFEX laser. The temporal and spatial overlaps of the incoming and redirected beams were measured with an optical interferometer and an x-ray pinhole camera. The plasma mirror performance was evaluated by measuring fast electrons, ions, and neutrons generated in the counter-propagating laser interaction with a Cu-doped deuterated film on both sides. The reflectivity and peak intensity were estimated as ∼50% and ∼5 × 1018 W/cm2, respectively. The platform could enable studies of counter-streaming charged particles in high-energy-density plasmas for fundamental and inertial confinement fusion research.

2.
Rev Sci Instrum ; 92(3): 033306, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820038

RESUMO

This paper reports on the absolute response of a Fuji BAS-TR image plate to relatively low-energy protons (<0.2 MeV) and carbon ions (<1 MeV) accelerated by a 10-TW-class compact high-intensity laser system. A Thomson parabola spectrometer was used to discriminate between different ion species while dispersing the ions according to their kinetic energy. Ion parabolic traces were recorded using an image plate detector overlaid with a slotted CR-39 solid-state detector. The obtained response function for the protons was reasonably extrapolated from previously reported higher-ion-energy response functions. Conversely, the obtained response function for carbon ions was one order of magnitude higher than the value extrapolated from previously reported higher-ion-energy response functions. In a previous study, it was determined that if the stopping range of carbon ions is comparable to or smaller than the grain size of the phosphor, then some ions will provide all their energy to the binder resin rather than the phosphor. As a result, it is believed that the imaging plate response will be reduced. Our results show good agreement with the empirical formula of Lelasseux et al., which does not consider photo-stimulated luminescence (PSL) reduction due to the urethane resin. It was shown that the PSL reduction due to the deactivation of the urethane resin is smaller than that previously predicted.

3.
Rev Sci Instrum ; 91(5): 053305, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32486709

RESUMO

This article reports the development of a compact Thomson parabola spectrometer for laser-accelerated ions that can measure angular distribution with a high energy resolution and has a variable measurable energy range. The angular-resolved energy spectra for different ion species can be measured in a single shot, and the sampling angle can be selected from outside the vacuum region. The electric and magnetic fields are applied to the ion dispersion by using a permanent magnetic circuit and annulus sector-shaped electrodes with a wedge configuration. The compact magnetic circuit consists of permanent magnets, fixed yokes, and movable yokes. The magnetic flux is intentionally leaked to the movable yokes, allowing the magnetic field to be adjusted from 53 mT to 259 mT. The annulus sector-shaped electrodes with a wedge configuration provide better trace separation for high-energy ions, retain the lower-energy part of the ion signal, and subject ions passing through all pinholes to an equivalent Lorentz force. The magnetic and electric fields are designed for measuring protons and carbon ions with an energy range of 0.1-5 MeV. The spectrometer allows for the adjustment of the observable energy range afterward according to the parameters of the accelerated ion.

4.
Phys Rev Lett ; 124(3): 035001, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-32031862

RESUMO

Fast isochoric laser heating is a scheme to heat matter with a relativistic intensity (>10^{18} W/cm^{2}) laser pulse for producing an ultrahigh-energy-density (UHED) state. We have demonstrated an efficient fast isochoric heating of a compressed dense plasma core with a multipicosecond kilojoule-class petawatt laser and an assistance of externally applied kilotesla magnetic fields for guiding fast electrons to the dense plasma. A UHED state of 2.2 PPa is achieved experimentally with 4.6 kJ of total laser energy that is one order of magnitude lower than the energy used in the conventional implosion scheme. A two-dimensional particle-in-cell simulation confirmed that diffusive heating from a laser-plasma interaction zone to the dense plasma plays an essential role to the efficient creation of the UHED state.

5.
Rev Sci Instrum ; 90(8): 083307, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31472620

RESUMO

Alpha particles generated by 7Li(p,α)4He and 19F(p,α)16O reactions are selectively detected in the presence of abundant primary protons by reducing the proton sensitivity of CR-39 using a potassium hydroxide-ethanol-water (PEW) etching solution. These nuclear reactions are induced in a LiF crystal using the laser-accelerated protons (4 × 1011 protons/pulse with a maximum energy of 3.3 MeV) generated and accelerated by the interaction of a 40-fs laser pulse with a polyethylene thin film target at a peak intensity of 5 × 1019 W/cm2. Subsequent etching of the CR-39 in the PEW solution (KOH: 17 wt. %; C2H5OH: 25 wt. %; H2O: 58 wt. %) permits the selective detection of 4.0 MeV alpha particles, which is independently confirmed by an experiment using alpha particles from an 241Am source. The described method is expected to be useful for research into nuclear reactions in laser plasma.

6.
Nat Commun ; 9(1): 3937, 2018 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-30258053

RESUMO

Fast isochoric heating of a pre-compressed plasma core with a high-intensity short-pulse laser is an attractive and alternative approach to create ultra-high-energy-density states like those found in inertial confinement fusion (ICF) ignition sparks. Laser-produced relativistic electron beam (REB) deposits a part of kinetic energy in the core, and then the heated region becomes the hot spark to trigger the ignition. However, due to the inherent large angular spread of the produced REB, only a small portion of the REB collides with the core. Here, we demonstrate a factor-of-two enhancement of laser-to-core energy coupling with the magnetized fast isochoric heating. The method employs a magnetic field of hundreds of Tesla that is applied to the transport region from the REB generation zone to the core which results in guiding the REB along the magnetic field lines to the core. This scheme may provide more efficient energy coupling compared to the conventional ICF scheme.

7.
Nat Commun ; 9(1): 623, 2018 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-29434203

RESUMO

High-power lasers in the relativistic intensity regime with multi-picosecond pulse durations are available in many laboratories around the world. Laser pulses at these intensities reach giga-bar level radiation pressures, which can push the plasma critical surface where laser light is reflected. This process is referred to as the laser hole boring (HB), which is critical for plasma heating, hence essential for laser-based applications. Here we derive the limit density for HB, which is the maximum plasma density the laser can reach, as a function of laser intensity. The time scale for when the laser pulse reaches the limit density is also derived. These theories are confirmed by a series of particle-in-cell simulations. After reaching the limit density, the plasma starts to blowout back toward the laser, and is accompanied by copious superthermal electrons; therefore, the electron energy can be determined by varying the laser pulse length.

8.
Phys Rev E ; 95(5-1): 053204, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28618498

RESUMO

Recent progress in the generation in the laboratory of a strong (>100-T) magnetic field enables us to investigate experimentally unexplored magnetohydrodynamics phenomena of a high-energy-density plasma, which an external magnetic field of 200-300 T notably affects due to anisotropic thermal conduction, even when the magnetic field pressure is much lower than the plasma pressure. The external magnetic field reduces electron thermal conduction across the external magnetic field lines because the Larmor radius of the thermal electrons in the external magnetic field is much shorter than the mean free path of the thermal electrons. The velocity of a thin polystyrene foil driven by intense laser beams in the strong external magnetic field is faster than that in the absence of the external magnetic field. Growth of sinusoidal corrugation imposed initially on the laser-driven polystyrene surface is enhanced by the external magnetic field because the plasma pressure distribution becomes nonuniform due to the external magnetic-field structure modulated by the perturbed plasma flow ablated from the corrugated surface.

9.
Rev Sci Instrum ; 87(4): 043502, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131669

RESUMO

Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 µm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

10.
Artigo em Inglês | MEDLINE | ID: mdl-26172803

RESUMO

A series of experiments were carried out to evaluate the energy-coupling efficiency from heating laser to a fuel core in the fast-ignition scheme of laser-driven inertial confinement fusion. Although the efficiency is determined by a wide variety of complex physics, from intense laser plasma interactions to the properties of high-energy density plasmas and the transport of relativistic electron beams (REB), here we simplify the physics by breaking down the efficiency into three measurable parameters: (i) energy conversion ratio from laser to REB, (ii) probability of collision between the REB and the fusion fuel core, and (iii) fraction of energy deposited in the fuel core from the REB. These three parameters were measured with the newly developed experimental platform designed for mimicking the plasma conditions of a realistic integrated fast-ignition experiment. The experimental results indicate that the high-energy tail of REB must be suppressed to heat the fuel core efficiently.

11.
Rev Sci Instrum ; 85(11): 11D634, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430210

RESUMO

A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons' energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

12.
Rev Sci Instrum ; 85(11): 11E604, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430350

RESUMO

A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.


Assuntos
Modelos Teóricos , Calibragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...