Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabet Med ; 36(5): 606-611, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30677187

RESUMO

AIMS: To evaluate the sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system using reference blood glucose levels during moderate-intensity exercise while on either full or reduced basal insulin dose in people with Type 1 diabetes. METHODS: Ten participants with Type 1 diabetes [four women, mean ± sd age 31.4 ± 9.0 years, BMI 25.5±3.8 kg/m2 , HbA1c 55±7 mmol/mol (7.2±0.6%)] exercised on a cycle ergometer for 55 min at a moderate intensity for 5 consecutive days at the clinical research facility, while receiving either their usual or a 75% basal insulin dose. After a 4-week washout period, participants performed the second exercise period having switched to the alternative basal insulin dose. During exercise, reference capillary blood glucose values were analysed using the fully enzymatic-amperometric method and compared with the interstitial glucose values obtained. Intermittently viewed continuous glucose monitoring accuracy was analysed according to median (interquartile range) absolute relative difference, and Clarke error grid and Bland-Altman analysis for overall glucose levels during exercise, stratified by glycaemic range and basal insulin dosing scheme (P<0.05). RESULTS: A total of 845 glucose values were available during exercise to evaluate intermittently viewed continuous glucose monitoring sensor performance. The median (interquartile range) absolute relative difference between the reference values and those obtained by the sensor across the glycaemic range overall was 22 (13.9-29.7)%, and was 36.3 (24.2-45.2)% during hypoglycaemia, 22.8 (14.6-30.6)% during euglycaemia and 15.4 (9-21)% during hyperglycaemia. Usual basal insulin dose was associated with a worse sensor performance during exercise compared with the reduced (75%) basal insulin dose [median (interquartile range) absolute relative difference: 23.7 (17.2-30.7)% vs 20.5 (12-28.1)%; P<0.001). CONCLUSIONS: The intermittently viewed continuous glucose monitoring sensor showed diminished accuracy during exercise. Absolute glucose readings derived from the sensor should be used cautiously and need confirmation by additional finger-prick blood glucose measurements.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Equipamentos e Provisões , Exercício Físico/fisiologia , Adulto , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/normas , Automonitorização da Glicemia/instrumentação , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Relação Dose-Resposta a Droga , Desenho de Equipamento , Equipamentos e Provisões/normas , Feminino , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Valor Preditivo dos Testes , Adulto Jovem
2.
Diabet Med ; 35(3): 347-351, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28755444

RESUMO

AIM: To compare bolus insulin delivery patterns during closed-loop home studies in adults with suboptimally [HbA1c 58-86 mmol/mol (7.5%-10%)] and well-controlled [58 mmol/mol (< 7.5%)] Type 1 diabetes. METHODS: Retrospective analysis of daytime and night-time insulin delivery during home use of closed-loop over 4 weeks. Daytime and night-time controller effort, defined as amount of insulin delivered by closed-loop relative to usual basal insulin delivery, and daytime bolus effort, defined as total bolus insulin delivery relative to total daytime insulin delivery were compared between both cohorts. Correlation analysis was performed between individual bolus behaviour (bolus effort and frequency) and daytime controller efforts, and proportion of time spent within and below sensor glucose target range. RESULTS: Individuals with suboptimally controlled Type 1 diabetes had significantly lower bolus effort (P = 0.038) and daily bolus frequency (P < 0.001) compared with those with well-controlled diabetes. Controller effort during both daytime (P = 0.007) and night-time (P = 0.005) were significantly higher for those with suboptimally controlled Type 1 diabetes. Time when glucose was within the target range (3.9-10.0 mmol/L) during daytime correlated positively with bolus effort (r = 0.37, P = 0.016) and bolus frequency (r = 0.33, P = 0.037). Time when glucose was below the target range during daytime was comparable in both groups (P = 0.36), and did not correlate significantly with bolus effort (r = 0.28, P = 0.066) or bolus frequency (r = -0.21, P = 0.19). CONCLUSION: More frequent bolusing and higher proportion of insulin delivered as bolus during hybrid closed-loop use correlated positively with time glucose was in target range. This emphasises the need for user input and educational support to benefit from this novel therapeutic modality.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Adulto , Diabetes Mellitus Tipo 1/sangue , Feminino , Hemoglobinas Glicadas/metabolismo , Serviços de Assistência Domiciliar , Humanos , Sistemas de Infusão de Insulina , Masculino , Estudos Retrospectivos
3.
N Engl J Med ; 373(22): 2129-2140, 2015 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-26379095

RESUMO

BACKGROUND: The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established. METHODS: In two multicenter, crossover, randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents. RESULTS: Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval [CI], 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, -11 mg per deciliter; 95% CI, -17 to -6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, -0.3%; 95% CI, -0.5 to -0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, -29 mg per deciliter; 95% CI, -39 to -20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic episodes occurred during the closed-loop phase when the closed-loop system was not in use. CONCLUSIONS: Among patients with type 1 diabetes, 12-week use of a closed-loop system, as compared with sensor-augmented pump therapy, improved glucose control, reduced hypoglycemia, and, in adults, resulted in a lower glycated hemoglobin level. (Funded by the JDRF and others; AP@home04 and APCam08 ClinicalTrials.gov numbers, NCT01961622 and NCT01778348.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Sistemas de Infusão de Insulina , Insulina/efeitos adversos , Adolescente , Adulto , Algoritmos , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...