Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 27(3): 462-467, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32517558

RESUMO

Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50-90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14-141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...