Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Clin Res Cardiol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112744

RESUMO

INTRODUCTION: The eradication of ventricular tachycardia (VT) isthmus sites constitutes the minimal procedural endpoint for VT ablation procedures. Contemporary high-resolution computed tomography (CT) imaging, in combination with computer-assisted analysis and segmentation of CT data, facilitates targeted elimination of VT isthmi. In this context, inHEART offers digitally rendered three-dimensional (3D) cardiac models which allow preoperative planning for VT ablations in ischemic and non-ischemic cardiomyopathies. To date, almost no data have been collected to compare the outcomes of VT ablations utilizing inHEART with those of traditional ablation approaches. METHODS: The presented data are derived from a retrospective analysis of n = 108 patients, with one cohort undergoing VT ablation aided by late-enhancement CT and subsequent analysis and segmentation by inHEART, while the other cohort received ablation through conventional methods like substrate mapping and activation mapping. The ablations were executed utilizing a 3D mapping system (Carto3), with the mapping generated via the CARTO® PENTARAY™ NAV catheter and subsequently merged with the inHEART model, if available. RESULTS: Results showed more successful outcome of ablations for the inHEART group with lower VT recurrence (27% vs. 42%, p < 0.06). Subsequent analyses revealed that patients with ischemic cardiomyopathies appeared to derive a significant benefit from inHEART-assisted VT ablation procedures, with a higher rate of successful ablation (p = 0.05). CONCLUSION: Our findings indicate that inHEART-guided ablation is associated with reduced VT recurrence compared to conventional procedures. This suggests that employing advanced imaging and computational modeling in VT ablation may be valuable for VT recurrences.

3.
Sci Rep ; 12(1): 12465, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864140

RESUMO

To evaluate the suitability of volume index measurement (VI) by either ultrasound (US) or computed tomography (CT) for the assessment of liver volume. Fifty-nine patients, 21 women, with a mean age of 66.8 ± 12.6 years underwent US of the liver followed immediately by abdominal CT. In US and CT imaging dorsoventral, mediolateral and craniocaudal liver diameters in their maximum extensions were assessed by two observers. VI was calculated by multiplication of the diameters divided by a constant (3.6). The liver volume determined by a manual segmentation in CT ("true liver volume") served as gold standard. True liver volume and calculated VI determined by US and CT were compared using Bland-Altman analysis. Mean differences of VI between observers were - 34.7% (- 90.1%; 20.7%) for the US-based and 1.1% (- 16.1%; 18.2%) for the CT-based technique, respectively. Liver volumes determined by semi-automated segmentation, US-based VI and CT-based VI, were as follows: 1.500 ± 347cm3; 863 ± 371cm3; 1.509 ± 432cm3. Results showed a great discrepancy between US-based VI and true liver volume with a mean bias of 58.3 ± 66.9%, and high agreement between CT-based VI and true liver volume with a low mean difference of 4.4 ± 28.3%. Volume index based on CT diameters is a reliable, fast and simple approach for estimating liver volume and can therefore be recommended for clinical practice. The usage of US-based volume index for assessment of liver volume should not be used due to its low accuracy of US in measurement of liver diameters.


Assuntos
Fígado , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia
4.
Sci Rep ; 12(1): 1257, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075169

RESUMO

To investigate the accuracy of liver diameters for estimation of liver size and to evaluate their application as tool for assessment of parenchymal liver disease. In the course of a population-based study, (SHIP) one thousand nine hundred thirty-nine volunteers underwent magnetic resonance imaging (MRI) of the liver including 3D gradient echo MRI sequences. Maximum liver diameters were measured in cranio-caudal (CC), anterior-posterior (AP), medial-lateral (ML) orientation. Diameters were compared with true liver volume assessed by liver segmentation. Additionally, age-dependent reference values for diameters were defined. Finally, accuracy of liver diameters was assessed to discriminate volunteers with healthy livers and participants with parenchymal changes, measured by MRI and laboratory. Reference values of liver diameters within the healthy population (n = 886) were defined as follows (mean ± standard deviation, confidence interval CI in cm): CC 17.2 ± 2, CI 13.6/21.2; AP 15.8 ± 1.9, CI 12.6/19.8; ML 19.7 ± 2.3, CI 15.8/24.6. There was a poor correlation using linear regression between liver diameter and true liver volume; CC 0.393, AP 0.359; ML 0.137. The AP direction shows the best correlation to discriminate between healthy and pathologic liver changes; AUC 0.78; p < 0.001, CC AUC 0.53; p < 0.001 and ML AUC 0.52; p = 0.008. Measurement of liver diameter, especially in the anterior-posterior direction is a simple option to detect chronic liver disease but less suitable for prediction of liver volume.


Assuntos
Fígado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Seguimentos , Voluntários Saudáveis , Humanos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Valores de Referência , Adulto Jovem
5.
AJNR Am J Neuroradiol ; 41(9): 1577-1583, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32763899

RESUMO

BACKGROUND AND PURPOSE: It is unknown whether deceleration of brain atrophy is associated with disability improvement in patients with MS. Our aim was to investigate whether patients with MS with disability improvement develop less brain atrophy compared with those who progress in disability or remain stable. MATERIALS AND METHODS: We followed 980 patients with MS for a mean of 4.8 ± 2.4 years. Subjects were divided into 3 groups: progress in disability (n = 241, 24.6%), disability improvement (n = 101, 10.3%), and stable (n = 638, 65.1%) at follow-up. Disability improvement and progress in disability were defined on the basis of the Expanded Disability Status Scale score change using standardized guidelines. Stable was defined as nonoccurrence of progress in disability or disability improvement. Normalized whole-brain volume was calculated using SIENAX on 3D T1WI, whereas the lateral ventricle was measured using NeuroSTREAM on 2D-T2-FLAIR images. The percentage brain volume change and percentage lateral ventricle volume change were calculated using SIENA and NeuroSTREAM, respectively. Differences among groups were investigated using ANCOVA, adjusted for age at first MR imaging, race, T2 lesion volume, and corresponding baseline structural volume and the Expanded Disability Status Scale. RESULTS: At first MR imaging, there were no differences among progress in disability, disability improvement, and the stable groups in whole-brain volume (P = .71) or lateral ventricle volume (P = .74). During follow-up, patients with disability improvement had the lowest annualized percentage lateral ventricle volume change (1.6% ± 2.7%) followed by patients who were stable (2.1% ± 3.7%) and had progress in disability (4.1% ± 5.5%), respectively (P < .001). The annualized percentage brain volume change values were -0.7% ± 0.7% for disability improvement, -0.8% ± 0.7% for stable, and -1.1% ± 1.1% for progress in disability (P = .001). CONCLUSIONS: Patients with MS who improve in their clinical disability develop less brain atrophy across time compared with those who progress.


Assuntos
Encéfalo/patologia , Progressão da Doença , Fatores Imunológicos/uso terapêutico , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla/patologia , Adulto , Atrofia/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Clin Radiol ; 74(7): 539-546, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30955836

RESUMO

AIM: To investigate the accuracy of ultrasonography in the assessment of hepatic steatosis using magnetic resonance imaging (MRI) as standard of reference and to explore the influence of additional hepatic iron overload. MATERIAL AND METHODS: A total of 2,783 volunteers (1,442 women, 1,341 men; mean age, 52.3±13.8 years) underwent confounder-corrected chemical-shift-encoded MRI of the liver at 1.5 T. Proton-density fat fraction (PDFF) and transverse relaxation rate (R2*) were calculated to estimate hepatic steatosis and liver iron overload, respectively. In addition, the presence of hepatic steatosis was assessed by B-mode ultrasonography. The sensitivity, specificity, and accuracy of hepatic ultrasonography were determined for different degrees of hepatic steatosis and different amounts of liver iron. RESULTS: MRI revealed hepatic steatosis in 40% of participants (n=1,112), which was mild in 68.9% (n=766), moderate in 26.7% (n=297), and severe in 4.4% (n=49) of patients. Ultrasonography detected hepatic steatosis in 37.8% (n=1,052), corresponding to 74.5% sensitivity and 86.6% specificity. The sensitivity of ultrasound increased with the amount of hepatic fat present and was 65.1%, 95%, and 96% for low, moderate, and high fat content; whereas the specificity was constantly high at 86.6%. The diagnostic accuracy of ultrasound for detection of hepatic steatosis did not vary significantly with the amount of liver iron present. CONCLUSION: Ultrasonography is an excellent tool to assess hepatic steatosis in the clinical setting with some limitations in patients with a low liver fat content. The detection of hepatic steatosis by ultrasonography is not influenced by liver iron.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Int J Cardiovasc Imaging ; 35(7): 1379-1386, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30850908

RESUMO

New protocols for coronary computed tomography angiography (CCTA) could lower the radiation dose for patients but influence the image quality. To compare image quality and radiation exposure in step-and-shoot CCTA and high-pitch spiral CCTA. Fifty-nine pairs of patients matched for weight, height, sex and heart rate were included in this study (74 m, 44 f, average age 60 years, age range 29-94 years). Step-and-shoot CCTA and high-pitch spiral CCTA was performed on a third generation dual-source CT in equally sized patient groups. The signal-to-noise ratio (SNR) in the ascending aorta and the coronary arteries were determined for each dataset. Image quality was rated using a five-point scale. We used the t-test for paired samples to compare SNR and effective dose, and the Wilcoxon test to compare image quality scores. Mean effective dose for the step-and-shoot protocol (4.15 ± 3.07 mSv) was significantly higher in comparison to the high-pitch spiral protocol (1.2 ± 0.69 mSv; p < 0.0001). Mean SNR was higher with the step-and-shoot protocol compared to the high-pitch spiral protocol in the aorta, in the left main and peripheral coronary arteries (p < 0.01), in the proximal right coronary artery (p = 0.027). Image quality scores were significantly better for the step-and-shoot protocol (p = 0.0003). Step-and-shoot CCTA has significantly better SNR and overall image quality compared to high-pitch spiral CCTA, but with a mean effective dose more than thrice as high.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Tomografia Computadorizada Espiral/efeitos adversos
8.
Eur J Neurol ; 26(1): 87-e8, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30103277

RESUMO

BACKGROUND: Cardiovascular diseases (CVDs) are more frequent in multiple sclerosis (MS) patients when compared to controls. In particular, CVDs are linked with higher accumulation of lesions and advanced brain atrophy. OBJECTIVE: To investigate whether CVDs contribute to accelerated lesion accumulation and brain atrophy over 5 years in patients with MS. METHODS: 194 MS patients and 43 controls without neurologic disease were followed for 5 years. Full physical, neurological evaluation, and structured questionnaire investigating CVD and risk factors (hypertension, hyperlipidemia, heart disease, smoking, diabetes, obesity/overweight) were collected using interview-based questionnaire and further cross-reference with electronic medical records. Lesion and brain atrophy outcomes were assessed with 3T MRI. ANCOVA adjusted for age, gender, and disease duration were used accordingly. False discovery rate correction was performed using Benjamini-Hochberg correction. RESULTS: Patients with diagnosis of heart disease showed higher white matter and whole brain volume loss compared to those without (-4.2% vs. -0.7%, P = 0.01 and -3.4% vs. -1.6%, P = 0.01, respectively). The percentage lateral ventricle volume change in MS patients with hypertension was higher compared to non-hypertensive patients (24.5% vs. 14.1%, P = 0.05). Hyperlipidemia, smoking, and obesity/overweight were not associated with progression of MRI-derived outcomes. CVDs did not contribute to larger lesion volume accrual over the 5-year period. The presence of CVDs was not associated with MRI-derived changes in the controls. CONCLUSIONS: Hypertension and heart disease contribute to advanced brain atrophy in MS patients. CVDs did not contribute to additional lesion accrual. CVD comorbidities in MS patients may contribute to neurodegenerative tissue injury that can be detected with brain MRI.


Assuntos
Encéfalo/patologia , Cardiopatias/etiologia , Hipertensão/etiologia , Esclerose Múltipla/complicações , Adulto , Idoso , Atrofia , Encéfalo/diagnóstico por imagem , Progressão da Doença , Registros Eletrônicos de Saúde , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Hipertensão/diagnóstico por imagem , Ventrículos Laterais/diagnóstico por imagem , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Exame Neurológico , Fatores de Risco , Inquéritos e Questionários
9.
AJNR Am J Neuroradiol ; 39(12): 2237-2242, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30467212

RESUMO

BACKGROUND AND PURPOSE: The assessment of brain atrophy in a clinical routine is not performed routinely in multiple sclerosis. Our aim was to determine the feasibility of brain atrophy measurement and its association with disability progression in patients with MS followed in a clinical routine for 5 years. MATERIALS AND METHODS: A total of 1815 subjects, 1514 with MS and 137 with clinically isolated syndrome and 164 healthy individuals, were collected retrospectively. Of 11,794 MR imaging brain scans included in the analysis, 8423 MRIs were performed on a 3T, and 3371 MRIs, on a 1.5T scanner. All patients underwent 3D T1WI and T2-FLAIR examinations at all time points of the study. Whole-brain volume changes were measured by percentage brain volume change/normalized brain volume change using SIENA/SIENAX on 3D T1WI and percentage lateral ventricle volume change using NeuroSTREAM on T2-FLAIR. RESULTS: Percentage brain volume change failed in 36.7% of the subjects; percentage normalized brain volume change, in 19.2%; and percentage lateral ventricle volume change, in 3.3% because of protocol changes, poor scan quality, artifacts, and anatomic variations. Annualized brain volume changes were significantly different between those with MS and healthy individuals for percentage brain volume change (P < .001), percentage normalized brain volume change (P = .002), and percentage lateral ventricle volume change (P = .01). In patients with MS, mixed-effects model analysis showed that disability progression was associated with a 21.9% annualized decrease in percentage brain volume change (P < .001) and normalized brain volume (P = .002) and a 33% increase in lateral ventricle volume (P = .004). CONCLUSIONS: All brain volume measures differentiated MS and healthy individuals and were associated with disability progression, but the lateral ventricle volume assessment was the most feasible.


Assuntos
Ventrículos Laterais/patologia , Esclerose Múltipla/patologia , Adulto , Atrofia/complicações , Atrofia/diagnóstico por imagem , Atrofia/patologia , Progressão da Doença , Feminino , Humanos , Ventrículos Laterais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Estudos Retrospectivos
10.
AJNR Am J Neuroradiol ; 39(4): 642-647, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29439125

RESUMO

BACKGROUND AND PURPOSE: Leptomeningeal contrast enhancement is found in patients with multiple sclerosis, though reported rates have varied. The use of 3D-fluid-attenuated inversion recovery pre- and postcontrast subtraction imaging may more accurately determine the frequency of leptomeningeal contrast enhancement. The purpose of this study was to investigate the frequency of leptomeningeal contrast enhancement using the pre- and postcontrast subtraction approach and to evaluate 3 different methods of assessing the presence of leptomeningeal contrast enhancement. MATERIALS AND METHODS: We enrolled 258 consecutive patients with MS (212 with relapsing-remitting MS, 32 with secondary-progressive MS, and 14 with clinically isolated syndrome) who underwent both pre- and 10-minute postcontrast 3D-FLAIR sequences after a single dose of gadolinium injection on 3T MR imaging. The analysis included leptomeningeal contrast-enhancement evaluation on 3D-FLAIR postcontrast images in native space (method A), on pre- and postcontrast 3D-FLAIR images in native space (method B), and on pre-/postcontrast 3D-FLAIR coregistered and subtracted images (method C, used as the criterion standard). RESULTS: In total, 51 (19.7%) patients with MS showed the presence of leptomeningeal contrast enhancement using method A; 39 (15.1%), using method B; and 39 (15.1%), using method C (P = .002). Compared with method C as the criterion standard, method A showed 89.8% sensitivity and 92.7% specificity, while method B showed 84.6% sensitivity and 97.3% specificity (P < .001) at the patient level. Reproducibility was the highest using method C (κ agreement, r = 088, P < .001). The mean time to analyze the 3D-FLAIR images was significantly lower with method C compared with methods A and B (P < .001). CONCLUSIONS: 3D-FLAIR postcontrast imaging offers a sensitive method for detecting leptomeningeal contrast enhancement in patients with MS. However, the use of subtraction imaging helped avoid false-positive cases, decreased reading time, and increased the accuracy of leptomeningeal contrast-enhancement foci detection in a clinical routine.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Meninges/diagnóstico por imagem , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio , Humanos , Masculino , Meninges/patologia , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Neurol Neurosurg Psychiatry ; 87(8): 885-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26917698

RESUMO

BACKGROUND: Natalizumab (NTZ), a monoclonal antibody to human α4ß1/ß7 integrin, is an effective therapy for multiple sclerosis (MS), albeit associated with progressive multifocal leukoencephalopathy (PML). Clinicians have been extending the dose of infusions with a hypothesis of reducing PML risk. The aim of the study is to evaluate the clinical consequences of reducing NTZ frequency of infusion up to 8 weeks 5 days. METHODS: A retrospective chart review in 9 MS centres was performed in order to identify patients treated with extended interval dosing (EID) regimens of NTZ. Patients were stratified into 3 groups based on EID NTZ treatment schedule in individual centres: early extended dosing (EED; n=249) every 4 weeks 3 days to 6 weeks 6 days; late extended dosing (LED; n=274) every 7 weeks to 8 weeks 5 days; variable extended dosing (n=382) alternating between EED and LED. These groups were compared with patients on standard interval dosing (SID; n=1093) every 4 weeks. RESULTS: 17% of patients on SID had new T2 lesions compared with 14% in EID (p=0.02); 7% of patients had enhancing T1 lesions in SID compared with 9% in EID (p=0.08); annualised relapse rate was 0.14 in the SID group, and 0.09 in the EID group. No evidence of clinical or radiographic disease activity was observed in 62% of SID and 61% of EID patients (p=0.83). No cases of PML were observed in EID group compared with 4 cases in SID cohort. CONCLUSIONS: Dosing intervals up to 8 weeks 5 days did not diminish effectiveness of NTZ therapy. Further monitoring is ongoing to evaluate if the risk of PML is reduced in patients on EID.


Assuntos
Leucoencefalopatia Multifocal Progressiva/induzido quimicamente , Leucoencefalopatia Multifocal Progressiva/prevenção & controle , Esclerose Múltipla/tratamento farmacológico , Natalizumab/administração & dosagem , Natalizumab/uso terapêutico , Adulto , Esquema de Medicação , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Natalizumab/efeitos adversos , Neuroimagem , Recidiva , Estudos Retrospectivos
12.
AJNR Am J Neuroradiol ; 37(6): 1010-6, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26892983

RESUMO

BACKGROUND AND PURPOSE: The effect of comorbidities on disease severity in MS has not been extensively characterized. We determined the association of comorbidities with MR imaging disease severity outcomes in MS. MATERIALS AND METHODS: Demographic and clinical history of 9 autoimmune comorbidities confirmed by retrospective chart review and quantitative MR imaging data were obtained in 815 patients with MS. The patients were categorized on the basis of the presence/absence of total and specific comorbidities. We analyzed the MR imaging findings, adjusting for key covariates and correcting for multiple comparisons. RESULTS: Two hundred forty-one (29.6%) study subjects presented with comorbidities. Thyroid disease had the highest frequency (n = 97, 11.9%), followed by asthma (n = 41, 5%), type 2 diabetes mellitus (n = 40, 4.9%), psoriasis (n = 33, 4%), and rheumatoid arthritis (n = 22, 2.7%). Patients with MS with comorbidities showed decreased whole-brain and cortical volumes (P < .001), gray matter volume and magnetization transfer ratio of normal-appearing brain tissue (P < .01), and magnetization transfer ratio of gray matter (P < .05). Psoriasis, thyroid disease, and type 2 diabetes mellitus comorbidities were associated with decreased whole-brain, cortical, and gray matter volumes (P < .05). Psoriasis was associated with a decreased magnetization transfer ratio of normal-appearing brain tissue (P < .05), while type 2 diabetes mellitus was associated with increased mean diffusivity (P < .01). CONCLUSIONS: The presence of comorbidities in patients with MS is associated with brain injury on MR imaging. Psoriasis, thyroid disease, and type 2 diabetes mellitus comorbidities were associated with more severe nonconventional MR imaging outcomes.


Assuntos
Doenças Autoimunes/epidemiologia , Encéfalo/patologia , Esclerose Múltipla/complicações , Esclerose Múltipla/patologia , Adulto , Lesões Encefálicas , Comorbidade , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
J Phys Chem A ; 120(9): 1347-57, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26106902

RESUMO

A novel method has been developed to improve sampling system response times for nominally "sticky" molecules such as HNO3 and NH3. The method reported here makes use of active, continuous passivation, where the instrument interfaces are continuously exposed to 0.01-1 ppm of fluorinated acidic or basic surfactants. To reduce HNO3 response times, perfluoroheptanoic acid and perfluorobutanesulfonic acid vapors are evaluated as passivation species. 1H,1H-perfluorooctylamine is used to improve NH3 response times. The resulting time responses using the perfluoroalkanoic acids are on the order of 0.4-0.7 s for a 75% quantitative recovery of HNO3, and 1-5 s for 90% recovery. Similar response time improvements are seen in detection of NH3 using perfluorooctylamine (<1 s for a 75% recovery, ∼ 2 s for 90% recovery). This generally applicable methodology significantly improves the capability of eddy covariance flux and real-time plume-based measurements of highly polar molecules that have historically been hampered by slow response times due to adsorption on sampling system surfaces. The utility of this approach is demonstrated by field measurements of HNO3 eddy covariance fluxes in a central U.S. prairie.

15.
Br J Dermatol ; 173(6): 1462-70, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26332527

RESUMO

BACKGROUND: The treatment of patients with metastatic melanomas that harbour BRAF V600E or V600K mutations with trametinib plus dabrafenib appears to be superior to treatment with vemurafenib alone. This treatment regimen is likely to become available in Switzerland in the near future. OBJECTIVES: To determine the cost-effectiveness of trametinib plus dabrafenib. METHODS: A Markov cohort simulation was conducted to model the clinical course of typical patients with metastatic melanoma. Information on response rates, clinical condition and follow-up treatments were derived and transition probabilities estimated based on the results of a clinical trial that compared treatment with trametinib plus dabrafenib vs. vemurafenib alone. RESULTS: Treatment with trametinib plus dabrafenib was estimated to cost an additional CHF199 647 (Swiss francs) on average and yield a gain of 0·52 quality-adjusted life years (QALYs), resulting in an incremental cost-effectiveness ratio of CHF385 603 per QALY. Probabilistic sensitivity analyses showed that a willingness-to-pay threshold of CHF100 000 per QALY would not be reached at the current US price of trametinib. CONCLUSIONS: The introduction of trametinib in Switzerland at US market prices for the treatment of metastatic BRAF V600-mutated melanoma with trametinib plus dabrafenib is unlikely to be cost-effective compared with vemurafenib monotherapy. A reduction in the total price of the combination therapy is required to achieve an acceptable cost-effectiveness ratio for this clinically promising treatment.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Melanoma/tratamento farmacológico , Neoplasias Cutâneas/tratamento farmacológico , Administração Oral , Protocolos de Quimioterapia Combinada Antineoplásica/economia , Análise Custo-Benefício , Progressão da Doença , Esquema de Medicação , Custos de Medicamentos , Humanos , Imidazóis/administração & dosagem , Imidazóis/economia , Melanoma/economia , Melanoma/genética , Mutação/genética , Metástase Neoplásica , Oximas/administração & dosagem , Oximas/economia , Proteínas Proto-Oncogênicas B-raf/genética , Piridonas/administração & dosagem , Piridonas/economia , Pirimidinonas/administração & dosagem , Pirimidinonas/economia , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Neoplasias Cutâneas/economia , Neoplasias Cutâneas/genética , Suíça , Resultado do Tratamento
17.
J Air Waste Manag Assoc ; 65(6): 699-706, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25976483

RESUMO

UNLABELLED: The 2009 Study of Houston Atmospheric Radical Precursors (SHARP) field campaign had several components that yielded information on the primary vehicular emissions of formaldehyde (HCHO) and nitrous acid (HONO), in addition to many other species. Analysis of HONO measurements at the Moody Tower site in Houston, TX, yielded emission ratios of HONO to the vehicle exhaust tracer species NOx and CO of 14 pptv/ppbv and 2.3 pptv/ppbv, somewhat smaller than recently published results from the Galleria site, although evidence is presented that the Moody Tower values should be upper limits to the true ratios of directly emitted HONO, and are consistent with ratios used in current standard emissions models. Several other Moody Tower emission ratios are presented, in particular a value for HCHO/CO of 2.4 pptv/ppbv. Considering only estimates of random errors, this would be significantly lower than a previous value, though the small sample size and possible systematic differences should be taken into account. Emission factors for CO, NOx, and HCHO, as well as various volatile organic compounds (VOCs), were derived from mobile laboratory measurements both in the Washburn Tunnel and in on-road exhaust plume observations. These two sets of results and others reported in the literature all agree well, and are substantially larger than the CO, NOx, and HCHO emission factors derived from the emission ratios reported from the Galleria site. IMPLICATIONS: Emission factors for the species measured in the various components of the 2009 SHARP campaign in Houston, TX, including HCHO, HONO, CO, CO2, nitrogen oxides, and VOCs, are needed to support regional air quality monitoring. Components of the SHARP campaign measured these species in several different ways, each with their own potential for systematic errors and differences in vehicle fleets sampled. Comparisons between data sets suggest that differences in sampling place and time may result in quite different emission factors, while also showing that different vehicle mixes can yield surprisingly similar emission factors.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Emissões de Veículos/análise , Modelos Teóricos , Estações do Ano , Texas
18.
J Interv Card Electrophysiol ; 41(3): 253-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25008255

RESUMO

BACKGROUND: A short baseline atrial fibrillation (AF) cycle length (CL) has been associated with a worse outcome after catheter ablation for AF, whereas the impact of a long baseline AFCL is unknown. We investigated the influence of AFCL on acute and long-term success in a large series of patients undergoing catheter ablation for persistent AF. METHODS: Overall, 177 consecutive patients undergoing catheter ablation of persistent AF using a sequential ablation approach were included in the analysis. AFCL was measured in the left atrial appendage (LAA) at baseline and following each ablation step. The primary endpoint was freedom from any atrial arrhythmia off antiarrhythmic drugs (AAD) with a single ablation procedure after 12 months. RESULTS: Mean AFCL was 164 ± 24 ms. A shorter AFCL was associated with longer AF duration, larger LA diameter, and longer procedure duration. Termination to sinus rhythm (SR) was achieved in 57 (32 %) patients. Baseline AFCL was shorter (161 ± 24 ms) in patients without AF termination compared to patients with AF termination (169 ± 23 m, p = 0.03). The primary endpoint was reached less frequently in patients with a short (<155 ms) AFCL (18 vs. 38.5 %, p = 0.006). Patients with an AFCL between 155 and 200 ms had the best outcome compared to patients with AFCL <155 or ≥200 ms (40 vs. 18 %, p = 0.003). CONCLUSIONS: Patients with a baseline AFCL between 155 and 200 ms have the best outcome after a single ablation procedure for persistent AF compared to patients with an AFCL of <155 or ≥200 ms.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Doença Crônica , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
19.
QJM ; 107(2): 147-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24023069

RESUMO

Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos por Eletricidade/etiologia , Jardinagem , Idoso , Campos Eletromagnéticos/efeitos adversos , Falha de Equipamento , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...