Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Alzheimers Dement ; 20(3): 1671-1681, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38081140

RESUMO

INTRODUCTION: Many neurocognitive evaluations involve auditory stimuli, yet there are no standard testing guidelines for individuals with hearing loss. The ensuring speech understanding (ESU) test was developed to confirm speech understanding and determine whether hearing accommodations are necessary for neurocognitive testing. METHODS: Hearing was assessed using audiometry. The probability of ESU test failure by hearing status was estimated in 2679 participants (mean age: 81.4 ± 4.6 years) using multivariate logistic regression. RESULTS: Only 2.2% (N = 58) of participants failed the ESU test. The probability of failure increased with hearing loss severity; similar results were observed for those with and without mild cognitive impairment or dementia. DISCUSSION: The ESU test is appropriate for individuals who have variable degrees of hearing loss and cognitive function. This test can be used prior to neurocognitive testing to help reduce the risk of hearing loss and compromised auditory access to speech stimuli causing poorer performance on neurocognitive evaluation.


Assuntos
Disfunção Cognitiva , Perda Auditiva , Humanos , Idoso , Idoso de 80 Anos ou mais , Fala , Perda Auditiva/diagnóstico , Perda Auditiva/complicações , Cognição , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/etiologia , Testes Auditivos/efeitos adversos , Testes Auditivos/métodos
2.
Ear Hear ; 44(4): 740-750, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36631948

RESUMO

OBJECTIVES: This study compared the measurement of the acoustic stapedius reflex threshold (ART) obtained using a traditional method with that obtained using an automated adaptive wideband (AAW) method. Participants included three groups of adults with normal hearing (NH), mild sensorineural hearing loss (SNHL), or moderate SNHL. The purpose of the study was to compare ARTs for the three groups and to determine which method had the best performance in detecting SNHL. DESIGN: Ipsilateral and contralateral ARTs were obtained using 0.5, 1, and 2 kHz tonal activators, and broadband noise (BBN) activators on a traditional admittance system (Clinical) at tympanometric peak pressures (TPP) and on an experimental wideband system using an AAW method at both ambient pressure and TPP. ART data previously reported for 39 NH adults with a mean age of 47.7 years were compared with data for 25 participants with mild SNHL with a mean age of 63.8 years, and 20 participants with moderate SNHL with a mean age of 65.7 years. Differences in ARTs between the normal-hearing and SNHL groups for the three methods were examined using a General Linear Model Repeated-Measures test. A receiver operating characteristic curve (ROC) analysis was also used to determine the ability of an ART test to detect SNHL. RESULTS: For the 0.5 kHz activator condition, there were no significant group mean differences in ART between NH and SNHL groups for either ipsilateral or contralateral activator presentation modes for the Clinical or AAW methods. There were significant group mean differences for the 1 and 2 kHz tonal activators and BBN activator for both ipsilateral and contralateral modes with greater differences in ART between groups for the AAW method than the Clinical method. In these conditions, the mean ART was lower for the AAW tests relative to the Clinical test. The greatest difference between groups was for the ipsilateral AAW tests for the comparison of NH with moderate SNHL for the BBN activator. This difference was approximately 20 dB for the AAW tests and 8 dB for the Clinical test. The ROC analysis showed that the area under the ROC curve (AUC) increased with the frequency of the activator stimulus and with the degree of hearing loss and was maximal for the BBN activator for both the AAW and Clinical methods for both ipsilateral and contralateral presentations. CONCLUSIONS: For ipsilateral and contralateral ART tests for activator frequencies above 0.5 kHz and BBN, listeners with SNHL generally had elevated ARTs compared with those with NH. The AAW method resulted in greater differences between SNHL groups and NH than the Clinical method. The AUC for detecting SNHL also increased with activator frequency and degree of hearing loss and was greatest for the BBN activator for the AAW method in both the ambient and TPP conditions. The results are encouraging for the use of an AAW ART method for the assessment of individuals with SNHL.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Perda Auditiva , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estapédio , Limiar Auditivo , Perda Auditiva Neurossensorial/diagnóstico , Testes de Impedância Acústica , Acústica , Audição , Reflexo , Reflexo Acústico
3.
Trends Hear ; 26: 23312165221129165, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36379607

RESUMO

Sensitivity to interaural time differences (ITDs) in acoustic hearing involves comparison of interaurally frequency-matched inputs. Bilateral cochlear-implant arrays are, however, only approximately aligned in angular insertion depth and scalar location across the cochleae. Interaural place-of-stimulation mismatch therefore has the potential to impact binaural perception. ITD left-right discrimination thresholds were examined in 23 postlingually-deafened adult bilateral cochlear-implant listeners, using low-rate constant-amplitude pulse trains presented via direct stimulation to single electrodes in each ear. Angular insertion depth and scalar location measured from computed-tomography (CT) scans were used to quantify interaural mismatch, and their association with binaural performance was assessed. Number-matched electrodes displayed a median interaural insertion-depth mismatch of 18° and generally yielded best or near-best ITD discrimination thresholds. Two listeners whose discrimination thresholds did not show this pattern were confirmed via CT to have atypical array placement. Listeners with more number-matched electrode pairs located in the scala tympani displayed better thresholds than listeners with fewer such pairs. ITD tuning curves as a function of interaural electrode separation were broad; bandwidths at twice the threshold minimum averaged 10.5 electrodes (equivalent to 5.9 mm for a Cochlear-brand pre-curved array). Larger angular insertion-depth differences were associated with wider bandwidths. Wide ITD tuning curve bandwidths appear to be a product of both monopolar stimulation and angular insertion-depth mismatch. Cases of good ITD sensitivity with very wide bandwidths suggest that precise matching of insertion depth is not critical for discrimination thresholds. Further prioritizing scala tympani location at implantation should, however, benefit ITD sensitivity.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Adulto , Humanos , Estimulação Acústica/métodos , Audição , Testes Auditivos , Localização de Som/fisiologia
4.
Otol Neurotol ; 43(6): 666-675, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35761459

RESUMO

HYPOTHESIS: Bilateral cochlear-implant (BI-CI) users will have a range of interaural insertion-depth mismatch because of different array placement or characteristics. Mismatch will be larger for electrodes located near the apex or outside scala tympani, or for arrays that are a mix of precurved and straight types. BACKGROUND: Brainstem superior olivary-complex neurons are exquisitely sensitive to interaural-difference cues for sound localization. Because these neurons rely on interaurally place-of-stimulation-matched inputs, interaural insertion-depth or scalar-location differences for BI-CI users could cause interaural place-of-stimulation mismatch that impairs binaural abilities. METHODS: Insertion depths and scalar locations were calculated from temporal-bone computed-tomography scans for 107 BI-CI users (27 Advanced Bionics, 62 Cochlear, 18 MED-EL). RESULTS: Median interaural insertion-depth mismatch was 23.4 degrees or 1.3 mm. Mismatch in the estimated clinically relevant range expected to impair binaural processing (>75 degrees or 3 mm) occurred for 13 to 19% of electrode pairs overall, and for at least three electrode pairs for 23 to 37% of subjects. There was a significant three-way interaction between insertion depth, scalar location, and array type. Interaural insertion-depth mismatch was largest for apical electrodes, for electrode pairs in two different scala, and for arrays that were both-precurved. CONCLUSION: Average BI-CI interaural insertion-depth mismatch was small; however, large interaural insertion-depth mismatch-with the potential to degrade spatial hearing-occurred frequently enough to warrant attention. For new BICI users, improved surgical techniques to avoid interaural insertion-depth and scalar mismatch are recommended. For existing BI-CI users with interaural insertion-depth mismatch, interaural alignment of clinical frequency tables might reduce negative spatial-hearing consequences.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Implante Coclear/métodos , Humanos , Rampa do Tímpano , Localização de Som/fisiologia , Tomografia
5.
Ear Hear ; 43(2): 370-378, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34320528

RESUMO

OBJECTIVES: Acoustic stapedius reflex threshold (ART) tests are included in a standard clinical acoustic immittance test battery as an objective cross-check with behavioral results and to help identify site of lesion. In traditional clinical test batteries, middle-ear admittance of a 226 Hz probe is estimated using ear-canal measurements in the presence of a reflex-activating stimulus. In the wideband (WB) acoustic immittance ART test used in this study, the pure-tone probe is replaced by a WB probe stimulus and changes in absorbed power are estimated using ear-canal measurements in the presence of the activator. The ART is defined as the lowest level at which a criterion change in admittance (clinical) or absorbed power (WB) is observed in the presence of the activator. In the present study, ARTs were obtained in adults with normal hearing using the clinical, manual method and with a new WB automated adaptive threshold detection method. It was hypothesized that the WB test would result in lower ARTs than the clinical test because reflex-related changes in power absorbance could be observed across multiple frequency bands in the WB test compared with a single frequency in the traditional test. DESIGN: Data were collected in a prospective research design. ARTs were obtained in ipsilateral and contralateral conditions using 500, 1000, 2000 Hz, and broadband noise (BBN) activators on a clinical system and on an experimental WB system. The bandwidth of the BBN activator was 125 to 4000 Hz on the clinical system and 200 to 8000 Hz on the wideband system. ARTs were estimated at both tympanometric peak pressure (TPP) and ambient pressure on the WB system. Data were collected in both ears of 39 adults (21 males) of mean age 47.7 years (range 23-72 years). Differences in ARTs among the three threshold estimation methods (clinical, WB at TPP, WB at ambient) were examined using the general linear model repeated measures test in SPSS. Post-hoc pairwise comparisons were completed with Bonferroni correction for multiple comparisons. Statistical significance was defined as p < 0.05 for all analyses. RESULTS: ARTs obtained on the WB system at TPP and ambient pressure were significantly lower than obtained on the clinical system. ARTs obtained on the WB system at TPP were significantly higher than at ambient pressure in the 500 and 2000 Hz ipsilateral conditions. CONCLUSIONS: WB automated adaptive ARTs in normal-hearing adults were lower than for clinical methods when measured at TPP and ambient pressure. Lower presentation levels required to estimate ART in the WB test may be more tolerable to patients. Patients with ARTs that are not present at the maximum level of a traditional reflex test may have present ARTs with a WB ART test, which may reduce the need to refer for additional testing for possible retrocochlear involvement. Automation of the test may allow clinicians more time to attend to the other requisite tasks of a hearing evaluation and make the system useful for telehealth applications.


Assuntos
Testes de Impedância Acústica , Reflexo Acústico , Testes de Impedância Acústica/métodos , Adulto , Idoso , Limiar Auditivo , Orelha Média , Feminino , Audição , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
6.
J Neurosci ; 41(49): 10161-10178, 2021 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-34725189

RESUMO

Bilateral cochlear implants (BI-CIs) or a CI for single-sided deafness (SSD-CI; one normally functioning acoustic ear) can partially restore spatial-hearing abilities, including sound localization and speech understanding in noise. For these populations, however, interaural place-of-stimulation mismatch can occur and thus diminish binaural sensitivity that relies on interaurally frequency-matched neurons. This study examined whether plasticity-reorganization of central neural pathways over time-can compensate for peripheral interaural place mismatch. We hypothesized differential plasticity across two systems: none for binaural processing but adaptation for pitch perception toward frequencies delivered by the specific electrodes. Interaural place mismatch was evaluated in 19 BI-CI and 23 SSD-CI human subjects (both sexes) using binaural processing (interaural-time-difference discrimination with simultaneous bilateral stimulation), pitch perception (pitch ranking for single electrodes or acoustic tones with sequential bilateral stimulation), and physical electrode-location estimates from computed-tomography (CT) scans. On average, CT scans revealed relatively little BI-CI interaural place mismatch (26° insertion-angle mismatch) but a relatively large SSD-CI mismatch, particularly at low frequencies (166° for an electrode tuned to 300 Hz, decreasing to 14° at 7000 Hz). For BI-CI subjects, the three metrics were in agreement because there was little mismatch. For SSD-CI subjects, binaural and CT measurements were in agreement, suggesting little binaural-system plasticity induced by mismatch. The pitch measurements disagreed with binaural and CT measurements, suggesting place-pitch plasticity or a procedural bias. These results suggest that reducing interaural place mismatch and potentially improving binaural processing by reprogramming the CI frequency allocation would be better done using CT-scan than pitch information.SIGNIFICANCE STATEMENT Electrode-array placement for cochlear implants (bionic prostheses that partially restore hearing) does not explicitly align neural representations of frequency information. The resulting interaural place-of-stimulation mismatch can diminish spatial-hearing abilities. In this study, adults with two cochlear implants showed reasonable interaural alignment, whereas those with one cochlear implant but normal hearing in the other ear often showed mismatch. In cases of mismatch, binaural sensitivity was best when the same cochlear locations were stimulated in both ears, suggesting that binaural brainstem pathways do not experience plasticity to compensate for mismatch. In contrast, interaurally pitch-matched electrodes deviated from cochlear-location estimates and did not optimize binaural sensitivity. Clinical correction of interaural place mismatch using binaural or computed-tomography (but not pitch) information may improve spatial-hearing benefits.


Assuntos
Adaptação Fisiológica/fisiologia , Implantes Cocleares , Plasticidade Neuronal/fisiologia , Percepção da Altura Sonora/fisiologia , Adulto , Idoso , Implante Coclear , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
7.
J Am Acad Audiol ; 26(1): 51-8; quiz 109-10, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25597460

RESUMO

BACKGROUND: Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To date, however, the effect of microphone location on speech recognition in noise has focused primarily on hearing aid users. PURPOSE: The purpose of this study was to (1) measure physical output for the T-Mic as compared with the integrated behind-the-ear (BTE) processor mic for various source azimuths, and (2) to investigate the effect of CI processor mic location for speech recognition in semi-diffuse noise with speech originating from various source azimuths as encountered in everyday communicative environments. RESEARCH DESIGN: A repeated-measures, within-participant design was used to compare performance across listening conditions. STUDY SAMPLE: A total of 11 adults with Advanced Bionics CIs were recruited for this study. DATA COLLECTION AND ANALYSIS: Physical acoustic output was measured on a Knowles Experimental Mannequin for Acoustic Research (KEMAR) for the T-Mic and BTE mic, with broadband noise presented at 0 and 90° (directed toward the implant processor). In addition to physical acoustic measurements, we also assessed recognition of sentences constructed by researchers at Texas Instruments, the Massachusetts Institute of Technology, and the Stanford Research Institute (TIMIT sentences) at 60 dBA for speech source azimuths of 0, 90, and 270°. Sentences were presented in a semi-diffuse restaurant noise originating from the R-SPACE 8-loudspeaker array. Signal-to-noise ratio was determined individually to achieve approximately 50% correct in the unilateral implanted listening condition with speech at 0°. Performance was compared across the T-Mic, 50/50, and the integrated BTE processor mic. RESULTS: The integrated BTE mic provided approximately 5 dB attenuation from 1500-4500 Hz for signals presented at 0° as compared with 90° (directed toward the processor). The T-Mic output was essentially equivalent for sources originating from 0 and 90°. Mic location also significantly affected sentence recognition as a function of source azimuth, with the T-Mic yielding the highest performance for speech originating from 0°. CONCLUSIONS: These results have clinical implications for (1) future implant processor design with respect to mic location, (2) mic settings for implant recipients, and (3) execution of advanced speech testing in the clinic.


Assuntos
Limiar Auditivo , Implantes Cocleares , Perda Auditiva/cirurgia , Ruído , Localização de Som/fisiologia , Percepção da Fala/fisiologia , Pré-Escolar , Feminino , Perda Auditiva/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Teste do Limiar de Recepção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...