Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Card Surg ; 25(6): 747-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20880085

RESUMO

We report a simple technique of LVAD outflow anastomosis as patch closure of a standard aortotomy during left ventricular assist device (LVAD) implant. Benefits are a single aortotomy, a low graft leaving ample native aorta for transplant, a wide-open LVAD outflow, and excellent aortic valve exposure.


Assuntos
Aorta/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Coração Auxiliar , Próteses e Implantes , Anastomose Cirúrgica/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos
3.
Ann Thorac Surg ; 88(4): e34-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19766774

RESUMO

In an attempt to allow physiologic expansion of the pulmonary autograft, yet limit late root dilation, we used stretch Gore-Tex material (W. L. Gore & Assoc, Flagstaff, AZ) as an external wrap. Follow-up cardiac computed tomography with reconstructed three-dimensional and dynamic images confirmed normal "triple bulge" sinus Valsalva geometry and preserved natural systolic expansion of the neoaortic root.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Materiais Biocompatíveis , Prótese Vascular , Polímeros de Fluorcarboneto , Artéria Pulmonar/cirurgia , Adulto , Angiografia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia Transesofagiana , Humanos , Masculino , Desenho de Prótese , Técnicas de Sutura , Tomografia Computadorizada por Raios X , Transplante Autólogo
4.
Ann Thorac Surg ; 87(6): 1795-800, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19463597

RESUMO

BACKGROUND: The truncated cone overall geometry of the native aortic root, an important factor in maintaining valvular competence, is significantly altered in cases of root aneurysms. We hypothesized that an early trial restoration of valve competence within the native aortic root followed by in situ three-dimensional measurements may lead to a more predictable functional reconstruction. METHODS: The operation started with downsizing annuloplasty followed by sinotubular junction plication until full valve competence was observed and tested with the saline squirt test. Subsequent measurements (basal ring and sinotubular junction size, the depth of each sinus of Valsalva) formed the basis of graft sizing and tailoring. Reconstruction was completed with a new proximal suture line technique combining David subannular pledgeted fixation with Yacoub remodeling. RESULTS: Ten patients were operated on during a 3-year period. Intraoperative (nonpressurized) competence by open testing translated into good postoperative valve function seen on transesophageal echocardiography. In situ measurements were done in the last 7 patients, and in 5 of them the restored root geometry was of a reverse cone (sinotubular junction 2 to 4 mm larger than basal ring size). CONCLUSIONS: Rebuilding the aortic root based on in situ measurements with a fully competent aortic valve is a conceptually new surgical approach. Our observations suggest that postoperative valve competence, particularly with elongated valve leaflets, may not depend on the normal truncated cone geometry.


Assuntos
Aorta/patologia , Aorta/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Adulto , Idoso , Humanos , Cuidados Intraoperatórios , Pessoa de Meia-Idade
5.
J Heart Lung Transplant ; 27(9): 1036-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18765198

RESUMO

Patients on a left ventricular assist device (LVAD) often have a high level of panel-reactive antibodies (PRA). Conventional therapy is to await a heart from a negative prospective-crossmatch donor. We transplanted three high-PRA patients with non-crossmatched hearts, using intra- and post-operative plasmapheresis and long-term T-/B-/plasma-cell therapy with alemtuzumab. Three highly sensitized patients (70%, 94% and 96% T-PRA; 63%, 24% and 73% B-PRA) were transplanted after 29, 187 and 94 days LVAD support. The first patient (Case 1) had an erroneous prospective negative crossmatch (due to an outside laboratory's use of the wrong patient's serum) with immediate allograft dysfunction. The correct serum showed a strongly positive crossmatch; plasmapheresis followed by alemtuzumab (20 mg intravenously) shortly after arrival in the ICU resulted in rapid hemodynamic improvement. Encouraged by this success, the next two patients (Cases 2 and 3) underwent LVAD explant and heart transplant with the next available ABO-identical, non-crossmatched donors, using plasmapheresis on bypass immediately before heart implant and alemtuzumab 20 mg intravenously upon ICU arrival, with uneventful courses. All three patients had positive retrospective T- and B-cell crossmatches. Maintenance immunosuppression consisted of cyclosporine and routine prednisone taper, with plasmapheresis as needed (Patient 1, x10; Patient 2, x5) based on diastolic dysfunction. Mycophenolate mofetil was started as a third agent several months post-transplant. Patients are presently New York Heart Association (NYHA) Class I at 26, 16 and 13 months post-transplant. In this small series with follow-up, immediate antibody removal with plasmapheresis, combined with alemtuzumab, a long-acting antibody to CD52 (expressed on T, B and some plasma cells), appears effective in allowing transplantation in sensitized, positive crossmatch recipients. Expanded use of this strategy could shorten LVAD support in many sensitized patients.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Anticorpos Antineoplásicos/uso terapêutico , Cardiomiopatias/cirurgia , Transplante de Coração/imunologia , Coração Auxiliar , Teste de Histocompatibilidade/métodos , Plasmaferese/métodos , Adulto , Alemtuzumab , Anticorpos/sangue , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais Humanizados , Anticorpos Antineoplásicos/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Adulto Jovem
6.
J Heart Valve Dis ; 17(1): 74-9; discussion 79-80, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18365572

RESUMO

BACKGROUND AND AIM OF THE STUDY: Currently, two different valve-sparing aortic root reconstruction methods are utilized, namely reimplantation and remodeling. Herein are reported the authors' early results with a new technique that integrates the two procedures. METHODS: Seven patients (age range: 25-69 years) underwent valve-sparing aortic root replacement with a new technique that integrates the principles of the David and Yacoub operations. The preoperative aortic root sizes were 4.9 to 7.0 cm, and six patients had aortic regurgitation (grade 1+ to 3+). Surgery was divisible into four stages: (i) External subcommissural (downsizing) annuloplasty; (ii) graft sizing and valve competency assessment with saline squirt test; (iii) sewing the individual tongues of a hand-scalloped Hemashield graft to the annular tissue with subvalvular pledgeted mattress sutures; and (iv) running suture lines to the commissural aspects of the aortic wall, followed by coronary reimplantation. RESULTS: All patients survived surgery. Intraoperative transesophageal echocardiography showed trace aortic incompetence (AR) in five patients, and mild or moderate AR each in one patient. Over a two-year period the technique was improved to the above-described, four-stage approach, which resulted in only trace AR in the final three patients. Early serial transthoracic echocardiography confirmed stable root dimensions and no progression of AR, except in an early patient. CONCLUSION: In the described technique, graft sizing is strictly tied to early intraoperative valve competency testing after an initial reconstruction within the native aortic root. The operation is then converted into a modified remodeling by suturing the triple-tongued (Yacoub) graft to the true aortic annulus with subannular pledgets (David principle). The operation involves significantly less dissection around the aortic root, and the entire scalloped annulus is stabilized in between the graft material and pledgets.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Sutura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...