Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 95(1): 7-12, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31793752

RESUMO

OBJECTIVES: Investigation of novel vertical radiation shield (VRS) in reducing operator radiation exposure. BACKGROUND: Radiation exposure to the operator remains an occupational health hazard in the cardiac catheterization laboratory (CCL). METHODS: A mannequin simulating an operator was placed near a computational phantom, simulating a patient. Measurement of dose equivalent and Air Kerma located the angle with the highest radiation, followed by a common magnification (8 in.) and comparison of horizontal radiation absorbing pads (HRAP) with or without VRS with two different: CCL, phantoms, and dosimeters. Physician exposure was subsequently measured prospectively with or without VRS during clinical procedures. RESULTS: Dose equivalent and Air Kerma to the mannequin was highest at left anterior oblique (LAO)-caudal angle (p < .005). Eight-inch magnification increased mGray by 86.5% and µSv/min by 12.2% compared to 10-in. (p < .005). Moving 40 cm from the access site lowered µSv/min by 30% (p < .005). With LAO-caudal angle and 8-in. magnification, VRS reduced µSv/min by 59%, (p < .005) in one CCL and µSv by 100% (p = .016) in second CCL in addition to HRAP. Prospective study of 177 procedures with HRAP, found VRS lowered µSv by 41.9% (µSv: 15.2 ± 13.4 vs. 26.2 ± 31.4, p = .001) with no difference in mGray. The difference was significant after multivariate adjustment for specified variables (p < .001). CONCLUSIONS: Operator radiation exposure is significantly reduced utilizing a novel VRS, HRAP, and distance from the X-ray tube, and consideration of lower magnification and avoiding LAO-caudal angles to lower radiation for both operator and patient.


Assuntos
Cateterismo Cardíaco , Exposição Ocupacional/prevenção & controle , Equipamentos de Proteção , Doses de Radiação , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Chumbo , Masculino , Manequins , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Medição de Risco , Fatores de Risco , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...