Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J R Soc Interface ; 21(215): 20230729, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38835246

RESUMO

In recent years, blending mechanistic knowledge with machine learning has had a major impact in digital healthcare. In this work, we introduce a computational pipeline to build certified digital replicas of cardiac electrophysiology in paediatric patients with congenital heart disease. We construct the patient-specific geometry by means of semi-automatic segmentation and meshing tools. We generate a dataset of electrophysiology simulations covering cell-to-organ level model parameters and using rigorous mathematical models based on differential equations. We previously proposed Branched Latent Neural Maps (BLNMs) as an accurate and efficient means to recapitulate complex physical processes in a neural network. Here, we employ BLNMs to encode the parametrized temporal dynamics of in silico 12-lead electrocardiograms (ECGs). BLNMs act as a geometry-specific surrogate model of cardiac function for fast and robust parameter estimation to match clinical ECGs in paediatric patients. Identifiability and trustworthiness of calibrated model parameters are assessed by sensitivity analysis and uncertainty quantification.


Assuntos
Eletrocardiografia , Cardiopatias Congênitas , Modelos Cardiovasculares , Humanos , Cardiopatias Congênitas/fisiopatologia , Eletrocardiografia/métodos , Criança
2.
Artigo em Inglês | MEDLINE | ID: mdl-38682804

RESUMO

In the fields of photolithographic patterning, optical anticounterfeiting, and information encryption, reversible photochromic materials with solid-state fluorescence are emerging as a potential class of systems. A design strategy for reversible photochromic materials has been proposed and synthesized through the introduction of photoactive thiophene groups into the molecular backbone of aryl vinyls, compounds with unique aggregation-induced emission properties, and solid-state reversible photocontrollable fluorescence and color-changing properties. This work develops novel photochromic inks, films, and cellulose hydrogels for enhancing the security of information encryption and anticounterfeiting technologies. They achieve rapid and reversible color change under ultraviolet light irradiation. Dependent upon the rate of color change, higher levels of time-resolved security can be achieved. This feature is important for enhancing the confidentiality of encrypted information and the reliability of security labels. Color-changing cellulose hydrogels, inks, and films consisting of three photochromic fluorescent molecules have quick photoactivity, great photoreversibility and photostability, and good processability, making them ideal for time-delayed anticounterfeiting and smart encryption. Furthermore, specialized algorithms are used to construct convolutional neural networks, and image analysis is performed on these systems, thus solving the current problem of the time-consuming information decryption process. This artificial intelligence method offers new opportunities for enhanced data encryption.

3.
IEEE Trans Biomed Eng ; 71(6): 1913-1925, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38300772

RESUMO

OBJECTIVE: Cardiovascular diseases, and the interventions performed to treat them, can lead to changes in the shape of patient vasculatures and their hemodynamics. Computational modeling and simulations of patient-specific vascular networks are increasingly used to quantify these hemodynamic changes, but they require modifying the shapes of the models. Existing methods to modify these shapes include editing 2D lumen contours prescribed along vessel centerlines and deforming meshes with geometry-based approaches. However, these methods can require extensive by-hand prescription of the desired shapes and often do not work robustly across a range of vascular anatomies. To overcome these limitations, we develop techniques to modify vascular models using physics-based principles that can automatically generate smooth deformations and readily apply them across different vascular anatomies. METHODS: We adapt Regularized Kelvinlets, analytical solutions to linear elastostatics, to perform elastic shape-editing of vascular models. The Kelvinlets are packaged into three methods that allow us to artificially create aneurysms, stenoses, and tortuosity. RESULTS: Our methods are able to generate such geometric changes across a wide range of vascular anatomies. We demonstrate their capabilities by creating sets of aneurysms, stenoses, and tortuosities with varying shapes and sizes on multiple patient-specific models. CONCLUSION: Our Kelvinlet-based deformers allow us to edit the shape of vascular models, regardless of their anatomical locations, and parametrically vary the size of the geometric changes. SIGNIFICANCE: These methods will enable researchers to more easily perform virtual-surgery-like deformations, computationally explore the impact of vascular shape on patient hemodynamics, and generate synthetic geometries for data-driven research.


Assuntos
Modelos Cardiovasculares , Humanos , Modelagem Computacional Específica para o Paciente , Hemodinâmica/fisiologia , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/fisiologia , Simulação por Computador
4.
J Hazard Mater ; 468: 133809, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38387178

RESUMO

Given the extensive need for the detection of hydrazine (N2H4) in the biomedical and chemical-pharmaceutical sectors, there is a necessity to devise a fast, sensitive, specific, and portable technique for precisely quantifying hydrazine at environmental levels. In our work, an "OFF-ON" type fluorescent probe namely 2-(4-(10-(naphthalen-2-yl)anthracen-9-yl)phenyl)isoindole-1,3-dione (NAP), which was inspired by the "Gabriel" reaction, was synthesized. The NAP fluorescent cellulose film successfully achieved the detection of hydrazine vapor with a LOD = 0.658 ppm. Compared to previous qualitative methods for detecting hydrazine, this study successfully achieved quantitative identification of hydrazine at low concentrations. In addition, a portable sensor device based on NAP cellulose film was successfully integrated, enabling ultra-sensitive, wireless, remote, and real-time detection of N2H4 vapor. It was determined that the probe (NAP) exhibited excellent detection performance when applied to various environmental samples including distilled water, tap water, creek water, soil and plants. This study introduces a potentially effective approach for detecting hydrazine in real-world settings.

5.
J Biomech Eng ; 146(7)2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38258957

RESUMO

We present a deep learning model to automatically generate computer models of the human heart from patient imaging data with an emphasis on its capability to generate thin-walled cardiac structures. Our method works by deforming a template mesh to fit the cardiac structures to the given image. Compared with prior deep learning methods that adopted this approach, our framework is designed to minimize mesh self-penetration, which typically arises when deforming surface meshes separated by small distances. We achieve this by using a two-stage diffeomorphic deformation process along with a novel loss function derived from the kinematics of motion that penalizes surface contact and interpenetration. Our model demonstrates comparable accuracy with state-of-the-art methods while additionally producing meshes free of self-intersections. The resultant meshes are readily usable in physics based simulation, minimizing the need for postprocessing and cleanup.


Assuntos
Aprendizado Profundo , Humanos , Simulação por Computador , Coração , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador
6.
bioRxiv ; 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38076810

RESUMO

In recent years, blending mechanistic knowledge with machine learning has had a major impact in digital healthcare. In this work, we introduce a computational pipeline to build certified digital replicas of cardiac electrophysiology in pediatric patients with congenital heart disease. We construct the patient-specific geometry by means of semi-automatic segmentation and meshing tools. We generate a dataset of electrophysiology simulations covering cell-to-organ level model parameters and utilizing rigorous mathematical models based on differential equations. We previously proposed Branched Latent Neural Maps (BLNMs) as an accurate and efficient means to recapitulate complex physical processes in a neural network. Here, we employ BLNMs to encode the parametrized temporal dynamics of in silico 12-lead electrocardiograms (ECGs). BLNMs act as a geometry-specific surrogate model of cardiac function for fast and robust parameter estimation to match clinical ECGs in pediatric patients. Identifiability and trustworthiness of calibrated model parameters are assessed by sensitivity analysis and uncertainty quantification.

7.
ArXiv ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37961745

RESUMO

Congenital heart disease (CHD) encompasses a spectrum of cardiovascular structural abnormalities, often requiring customized treatment plans for individual patients. Computational modeling and analysis of these unique cardiac anatomies can improve diagnosis and treatment planning and may ultimately lead to improved outcomes. Deep learning (DL) methods have demonstrated the potential to enable efficient treatment planning by automating cardiac segmentation and mesh construction for patients with normal cardiac anatomies. However, CHDs are often rare, making it challenging to acquire sufficiently large patient cohorts for training such DL models. Generative modeling of cardiac anatomies has the potential to fill this gap via the generation of virtual cohorts; however, prior approaches were largely designed for normal anatomies and cannot readily capture the significant topological variations seen in CHD patients. Therefore, we propose a type- and shape-disentangled generative approach suitable to capture the wide spectrum of cardiac anatomies observed in different CHD types and synthesize differently shaped cardiac anatomies that preserve the unique topology for specific CHD types. Our DL approach represents generic whole heart anatomies with CHD type-specific abnormalities implicitly using signed distance fields (SDF) based on CHD type diagnosis, which conveniently captures divergent anatomical variations across different types and represents meaningful intermediate CHD states. To capture the shape-specific variations, we then learn invertible deformations to morph the learned CHD type-specific anatomies and reconstruct patient-specific shapes. Our approach has the potential to augment the image-segmentation pairs for rarer CHD types for cardiac segmentation and generate cohorts of CHD cardiac meshes for computational simulation.

8.
Polymers (Basel) ; 15(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37835979

RESUMO

Conjugated microporous polymers (CMPs) have important applications in the fields of optoelectronics and sewage treatment due to their high specific surface area, broad visible absorption, processability and simple synthesis process. Biocompatibility, recycling, mass production and solar photodegradation are particularly important in wastewater treatment. Here, A CMP with a high specific surface area and a hierarchical pore structure (CPOP) was constructed based on 4,4',4″-Tris(carbazol-9-yl)-triphenylamine (3CZ-TPA). Furthermore, a CMP-loaded wood aerogel (CPOP/wood aerogel) with physical adsorption, chemical degradation, bacterial inhibition and self-cleaning properties was prepared by in situ polymerization and used for wastewater treatment. The obtained CPOP/wood aerogel is highly biocompatible and easy to recycle. In addition, the inherent broad visible light absorption property of CPOP endows it with promising photocatalytic properties. Subsequently, we investigated the photocatalytic mechanism of CPOP, and the results showed that it was mainly affected by peroxyl radicals, which implied and confirmed its microbial self-cleaning for secondary cleaning of water pollutants. The reported studies on CPOP/wood aerogel provide a new direction for water purification materials with excellent adsorption, degradation and antibacterial properties.

10.
Front Med (Lausanne) ; 10: 1051034, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37215717

RESUMO

Approximately 5% of advanced colorectal carcinomas (CRCs) and 12-15% of early CRCs are microsatellite instability-high (MSI-H) or mismatch repair-deficient (dMMR) tumors. Nowadays, PD-L1 inhibitors or combined CTLA4 inhibitors are the major strategies for advanced or metastatic MSI-H colorectal cancer, but some people still show drug resistance or progression. Combined immunotherapy has been shown to expand the benefit population in non-small-cell lung carcinoma (NSCLC), hepatocellular carcinoma (HCC), and other tumors while reducing the incidence of hyper-progression disease (HPD). Nevertheless, advanced CRC with MSI-H remains rare. In this article, we describe a case of an elder patient with MSI-H advanced CRC carrying MDM4 amplification and DNMT3A co-mutation who responded to sintilimab plus bevacizumab and chemotherapy as the first-line treatment without obvious immune-related toxicity. Our case provides a new treatment option for MSI-H CRC with multiple risk factors of HPD and highlights the importance of predictive biomarkers in personalized immunotherapy.

11.
IEEE Trans Med Imaging ; 42(2): 533-545, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36327186

RESUMO

Patient-specific cardiac modeling combines geometries of the heart derived from medical images and biophysical simulations to predict various aspects of cardiac function. However, generating simulation-suitable models of the heart from patient image data often requires complicated procedures and significant human effort. We present a fast and automated deep-learning method to construct simulation-suitable models of the heart from medical images. The approach constructs meshes from 3D patient images by learning to deform a small set of deformation handles on a whole heart template. For both 3D CT and MR data, this method achieves promising accuracy for whole heart reconstruction, consistently outperforming prior methods in constructing simulation-suitable meshes of the heart. When evaluated on time-series CT data, this method produced more anatomically and temporally consistent geometries than prior methods, and was able to produce geometries that better satisfy modeling requirements for cardiac flow simulations. Our source code and pretrained networks are available at https://github.com/fkong7/HeartDeformNets.


Assuntos
Coração , Telas Cirúrgicas , Humanos , Simulação por Computador , Coração/diagnóstico por imagem , Software , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos
12.
Nat Commun ; 13(1): 5189, 2022 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-36057648

RESUMO

Nerve agents, one of the most toxic chemical warfare agents, seriously threaten human life and public security. The high toxicity of nerve agents makes the development of fluorescence sensors with suitable limit of detection challenging. Here, we propose a sensor design based on a conjugated microporous polymer film for the detection of diethyl chlorophosphate, a substitute of Sarin, with low detection limit of 2.5 ppt. This is due to the synergy of the susceptible on-off effect of hybridization and de-hybridization of hybrid local and charge transfer (HLCT) materials and the microporous structure of CMP films facilitating the inward diffusion of DCP vapors, and the extended π-conjugated structure. This strategy provides a new idea for the future development of gas sensors. In addition, a portable sensor is successfully integrated based on TCzP-CMP films that enables wireless, remote, ultrasensitive, and real-time detection of DCP vapors.


Assuntos
Substâncias para a Guerra Química , Agentes Neurotóxicos , Humanos , Substâncias para a Guerra Química/análise , Substâncias para a Guerra Química/química , Gases , Polímeros/química , Sarina
13.
Med Image Anal ; 74: 102222, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34543913

RESUMO

Automated construction of surface geometries of cardiac structures from volumetric medical images is important for a number of clinical applications. While deep-learning-based approaches have demonstrated promising reconstruction precision, these approaches have mostly focused on voxel-wise segmentation followed by surface reconstruction and post-processing techniques. However, such approaches suffer from a number of limitations including disconnected regions or incorrect surface topology due to erroneous segmentation and stair-case artifacts due to limited segmentation resolution. We propose a novel deep-learning-based approach that directly predicts whole heart surface meshes from volumetric CT and MR image data. Our approach leverages a graph convolutional neural network to predict deformation on mesh vertices from a pre-defined mesh template to reconstruct multiple anatomical structures in a 3D image volume. Our method demonstrated promising performance of generating whole heart reconstructions with as good or better accuracy than prior deep-learning-based methods on both CT and MR data. Furthermore, by deforming a template mesh, our method can generate whole heart geometries with better anatomical consistency and produce high-resolution geometries from lower resolution input image data. Our method was also able to produce temporally-consistent surface mesh predictions for heart motion from CT or MR cine sequences, and therefore can potentially be applied for efficiently constructing 4D whole heart dynamics. Our code and pre-trained networks are available at https://github.com/fkong7/MeshDeformNet.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Redes Neurais de Computação , Telas Cirúrgicas
14.
IEEE Trans Med Imaging ; 40(12): 3543-3554, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34138702

RESUMO

The emergence of deep learning has considerably advanced the state-of-the-art in cardiac magnetic resonance (CMR) segmentation. Many techniques have been proposed over the last few years, bringing the accuracy of automated segmentation close to human performance. However, these models have been all too often trained and validated using cardiac imaging samples from single clinical centres or homogeneous imaging protocols. This has prevented the development and validation of models that are generalizable across different clinical centres, imaging conditions or scanner vendors. To promote further research and scientific benchmarking in the field of generalizable deep learning for cardiac segmentation, this paper presents the results of the Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation (M&Ms) Challenge, which was recently organized as part of the MICCAI 2020 Conference. A total of 14 teams submitted different solutions to the problem, combining various baseline models, data augmentation strategies, and domain adaptation techniques. The obtained results indicate the importance of intensity-driven data augmentation, as well as the need for further research to improve generalizability towards unseen scanner vendors or new imaging protocols. Furthermore, we present a new resource of 375 heterogeneous CMR datasets acquired by using four different scanner vendors in six hospitals and three different countries (Spain, Canada and Germany), which we provide as open-access for the community to enable future research in the field.


Assuntos
Coração , Imageamento por Ressonância Magnética , Técnicas de Imagem Cardíaca , Coração/diagnóstico por imagem , Humanos
15.
J Biomech Eng ; 142(11)2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32766785

RESUMO

Computational fluid dynamics (CFD) modeling of left ventricle (LV) flow combined with patient medical imaging data has shown great potential in obtaining patient-specific hemodynamics information for functional assessment of the heart. A typical model construction pipeline usually starts with segmentation of the LV by manual delineation followed by mesh generation and registration techniques using separate software tools. However, such approaches usually require significant time and human efforts in the model generation process, limiting large-scale analysis. In this study, we propose an approach toward fully automating the model generation process for CFD simulation of LV flow to significantly reduce LV CFD model generation time. Our modeling framework leverages a novel combination of techniques including deep-learning based segmentation, geometry processing, and image registration to reliably reconstruct CFD-suitable LV models with little-to-no user intervention.1 We utilized an ensemble of two-dimensional (2D) convolutional neural networks (CNNs) for automatic segmentation of cardiac structures from three-dimensional (3D) patient images and our segmentation approach outperformed recent state-of-the-art segmentation techniques when evaluated on benchmark data containing both magnetic resonance (MR) and computed tomography(CT) cardiac scans. We demonstrate that through a combination of segmentation and geometry processing, we were able to robustly create CFD-suitable LV meshes from segmentations for 78 out of 80 test cases. Although the focus on this study is on image-to-mesh generation, we demonstrate the feasibility of this framework in supporting LV hemodynamics modeling by performing CFD simulations from two representative time-resolved patient-specific image datasets.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
16.
J Biomech ; 104: 109730, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32147238

RESUMO

Mitral valve (MV) repair with the MitraClip device has been shown to reduce mitral regurgitation severity and improve clinical outcomes in symptomatic patients at high surgical risk. MitraClip was recently approved in the US for the treatment of functional mitral regurgitation (FMR), which significantly expands the number of patients that can be treated with this device. This study aims to quantify the morphologic changes and evaluate the biomechanical interaction between the MitraClip device and the mitral apparatus of a real patient case with FMR using computational modeling. MitraClip procedures using a central and a lateral clip were simulated in a validated MV-left ventricle finite element (FE) model with severe MR. The patient-specific model integrated detailed geometries of the left ventricle, mitral leaflets and chordae, incorporated age- and gender-matched nonlinear hyperelastic human material properties, and accounted for chordae tethering forces. Central and lateral positioning gave similar biomechanical outcomes resulting in an improved but incomplete MV coaptation. Antero-posterior distance, annulus area, valve opening orifice area, and regurgitant orifice area decreased by up to 26%, 19%, 48% and 63% when compared to the pre-clip model, respectively. Anterior and posterior leaflet peak stresses increased by up to 64% and 62% after clip placement, respectively, and were located at the region of clip grasp. Similarly, anterior and posterior leaflet peak strains increased by up to 20% and 10%, respectively. FE modeling, as used here, can be a powerful tool to examine the complex MitraClip-host biomechanical interaction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Análise de Elementos Finitos , Ventrículos do Coração , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
17.
PLoS One ; 13(6): e0198331, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29902273

RESUMO

OBJECTIVES: Functional mitral regurgitation (FMR) is a significant complication of left ventricle (LV) dysfunction associated with poor prognosis and commonly treated by undersized ring annuloplasty. This study aimed to quantitatively simulate the treatment outcomes and mitral valve (MV) biomechanics following ring annulopalsty and papillary muscle relocation (PMR) procedures for a FMR patient. METHODS: We utilized a validated finite element model of the left heart for a patient with severe FMR and LV dilation from our previous study and simulated virtual ring annuloplasty procedures with various sizes of Edwards Classic and GeoForm annuloplasty rings. The model included detailed geometries of the left ventricle, mitral valve, and chordae tendineae, and incorporated age- and gender- matched nonlinear, anisotropic hyperelastic tissue material properties, and simulated chordal tethering at diastole due to LV dilation. RESULTS: Ring annuloplasty with either the Classic or GeoForm ring improved leaflet coaptation and increased the total leaflet closing force while increased posterior mitral leaflet (PML) stresses and strains. Classic rings resulted in larger coaptation forces and areas compared to GeoForm rings. The PMR procedure further improved the leaflet coaptation, decreased the PML stress and strain for both ring shapes and all sizes in this patient model. CONCLUSIONS: This study demonstrated that a rigorously developed patient-specific computational model can provide useful insights into annuloplasty repair techniques for the treatment of FMR patients and could potentially serve as a tool to assist in pre-operative planning for MV repair surgical or interventional procedures.


Assuntos
Cordas Tendinosas/anatomia & histologia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Anisotropia , Análise de Elementos Finitos , Próteses Valvulares Cardíacas , Humanos , Modelos Biológicos
18.
Ann Biomed Eng ; 46(8): 1112-1127, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29663193

RESUMO

Despite the growing clinical interest in the tricuspid valve (TV), there is an incomplete understanding of TV biomechanics which is important in normal TV function and successful TV repair techniques. Computational models with patient-specific human TV geometries can provide a quantitative understanding of TV biomechanic. Therefore, this study aimed to develop finite element (FE) models of human TVs from multi-slice computed tomography (MSCT) images to investigate chordal forces and leaflet stresses and strains. Three FE models were constructed for human subjects with healthy TVs from MSCT images and incorporated detailed leaflet geometries, realistic nonlinear anisotropic hyperelastic material properties of human TV, and physiological boundary conditions tracked from MSCT images. TV closure from diastole to systole was simulated. Chordal lengths were iteratively adjusted until the simulated TV geometries were in good agreement with the "true" geometries reconstructed from MSCT images at systole. Larger chordal forces were found on the strut (or basal) chords than on the rough zone chords and the total forces applied on the anterior papillary muscles by the strut chords were higher than those on the posterior or septal papillary muscles. At peak systolic pressure, the average maximum stress on the middle sections of the leaflets ranged from 30 to 90 kPa, while the average maximum principal strain values ranged from 0.16 to 0.30. The results from healthy TVs can serve as baseline biomechanical metrics of TV mechanics and may be used to inform TV repair device design. The computational approach developed could be one step towards developing computational models that may support pre-operative planning in complex TV repair procedures in the future.


Assuntos
Simulação por Computador , Análise de Elementos Finitos , Modelos Cardiovasculares , Tomografia Computadorizada por Raios X , Valva Tricúspide , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia
19.
Cardiovasc Eng Technol ; 8(1): 3-16, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28070866

RESUMO

Functional mitral regurgitation (FMR) is a significant complication of left ventricular dysfunction and strongly associated with a poor prognosis. In this study, we developed a patient-specific finite element (FE) model of the mitral apparatus in a FMR patient which included: both leaflets with thickness, annulus, chordae tendineae, and chordae insertions on the leaflets and origins on the papillary muscles. The FE model incorporated human age- and gender-matched anisotropic hyperelastic material properties, and MV closure at systole was simulated. The model was validated by comparing the FE results from valve closure simulation with the in vivo geometry of the MV at systole. It was found that the FE model could not replicate the in vivo MV geometry without the application of tethering pre-tension force in the chordae at diastole. Upon applying the pre-tension force and performing model optimization by adjusting the chordal length, position, and leaflet length, a good agreement between the FE model and the in vivo model was established. Not only were the chordal forces high at both diastole and systole, but the tethering force on the anterior papillary muscle was higher than that of the posterior papillary muscle, which resulted in an asymmetrical gap with a larger orifice area at the anterolateral commissure resulting in MR. The analyses further show that high peak stress and strain were found at the chordal insertions where large chordal tethering forces were found. This study shows that the pre-tension tethering force plays an important role in accurately simulating the MV dynamics in this FMR patient, particularly in quantifying the degree of leaflet coaptation and stress distribution. Due to the complexity of the disease, the patient-specific computational modeling procedure of FMR patients presented should be further evaluated using a large patient cohort. However, this study provides useful insights into the MV biomechanics of a FMR patient, and could serve as a tool to assist in pre-operative planning for MV repair or replacement surgical or interventional procedures.


Assuntos
Análise de Elementos Finitos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Modelos Biológicos , Idoso , Cordas Tendinosas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Músculos Papilares/fisiopatologia , Reprodutibilidade dos Testes , Sístole/fisiologia
20.
Artigo em Inglês | MEDLINE | ID: mdl-27557429

RESUMO

To conduct a patient-specific computational modeling of the aortic valve, 3-D aortic valve anatomic geometries of an individual patient need to be reconstructed from clinical 3-D cardiac images. Currently, most of computational studies involve manual heart valve geometry reconstruction and manual finite element (FE) model generation, which is both time-consuming and prone to human errors. A seamless computational modeling framework, which can automate this process based on machine learning algorithms, is desirable, as it can not only eliminate human errors and ensure the consistency of the modeling results but also allow fast feedback to clinicians and permits a future population-based probabilistic analysis of large patient cohorts. In this study, we developed a novel computational modeling method to automatically reconstruct the 3-D geometries of the aortic valve from computed tomographic images. The reconstructed valve geometries have built-in mesh correspondence, which bridges harmonically for the consequent FE modeling. The proposed method was evaluated by comparing the reconstructed geometries from 10 patients with those manually created by human experts, and a mean discrepancy of 0.69 mm was obtained. Based on these reconstructed geometries, FE models of valve leaflets were developed, and aortic valve closure from end systole to middiastole was simulated for 7 patients and validated by comparing the deformed geometries with those manually created by human experts, and a mean discrepancy of 1.57 mm was obtained. The proposed method offers great potential to streamline the computational modeling process and enables the development of a preoperative planning system for aortic valve disease diagnosis and treatment.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Imageamento Tridimensional/métodos , Aprendizado de Máquina , Simulação por Computador , Análise de Elementos Finitos , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...