Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(20)2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37895605

RESUMO

Metals subjected to the oral environment are prone to corrosion over time and this can be harmful. Metallic restoration components such as dental subgingival implant abutments are exposed to pH changes and different ions while in contact with saliva. The aim of the study was to evaluate the corrosion resistance of titanium dental implant abutments and to compare and contrast the surface characteristics of these alloys before and after corrosion. The corrosion examination (Ecorr, jcorr, OCP, polarization curve) of two implant abutments (TiDesign EV, Astra Tech, Dentsply, York, PA, USA; Individual Titanium Abutment, Apollo Implants Components, Pabianice, Poland) was performed in 0.9% NaCl and 5% HCl. Moreover, specimens were investigated using SEM-EDS before and after the corrosion test. The value of jcorr in NaCl was higher for Astra (34.2 × 10-8 ± 2.5 × 10-8 A/cm2) than for Apollo (8.8 × 10-8 ± 2.5 × 10-8 A/cm2). Whereas, in HCl, the opposite relationship was observed (Astra 2.9 × 10-4 ± 0.8 × 10-4 A/cm2 and Apollo 62.7 × 10-4 ± 9.3 × 10-4 A/cm2). An average reactive anodic current density in NaCl for Astra amounted up to ~0.2 × 10-5-1.5 × 10-5 A/cm2, while for Apollo-up to ~3.3-9.7 × 10-7 A/cm2. The composition of both alloys after corrosion in NaCl demonstrated some changes: a decrease in the Ti, and Al and an increase in oxygen content. Hence, both alloys after corrosion in HCl demonstrated some minor changes in the elemental composition. Based on the results it can be concluded that: 1. Astra and Apollo abutments revealed good corrosion resistance and a passivation layer on the surface. 2. Apollo abutments exhibited better corrosion resistance in a neutral environment, suggesting that Astra abutments were found to be more resistant to corrosion in an acidic medium.

2.
Materials (Basel) ; 16(17)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37687699

RESUMO

Pathological tooth wear is an escalating social problem. Occlusal veneers can be an alternative to traditional prosthetic restorations such as crowns, inlays, and onlays. BACKGROUND: The aim of this study is to assess the fracture resistance of occlusal veneers made of various materials depending on their thickness. METHODS: In total, 120 occlusal veneers were examined. The restorations were made of four ceramics: leucite LC (IPS Empress Esthetic), hybrid HC (Vita Enamic), lithium disilicate LDC (IPS e.max Press), and zirconium oxide ZOC (Ceramill Zolid HT). A total of 30 veneers were made of each material, 10 for each of the three thicknesses: 1 mm, 1.5 mm, 2 mm. The restorations were cemented on identical abutments duplicated from the developed phantom tooth 35 (KaVo) with composite cement (All Bond Universal). The samples prepared in this way were subjected to a compressive strength test in a universal testing machine. Statistical analysis of the results was performed. RESULTS: The average fracture resistance of occlusal veneers made of zirconium oxide ceramic was 1086-1640 N, of lithium disilicate ceramics 456-1044 N, of hybrid ceramics 449-576 N, and of leucite ceramics 257-499 N. CONCLUSIONS: Occlusal veneers made of ceramics, zirconium oxide and lithium disilicate, had the highest resistance to fractures. Restorations made of leucite ceramics turned out to be the least resistant to forces. The greater the thickness of the ceramic occlusal veneers, the greater their fracture resistance.

3.
Materials (Basel) ; 16(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37570123

RESUMO

The surface of zirconia-based dental ceramic restorations require preparation prior to adhesive cementation. The purpose of this study was to assess the influence of airborne-particle abrasion with different sizes of alumina particles (50 µm, 110 µm, or 250 µm) on the mechanical strength of zirconia-based ceramics' frameworks and on the extent of phase transformations. A fracture resistance test was performed. The central surface of the frameworks was subjected to a load [N]. The identification and quantitative determination of the crystalline phase present in the zirconia specimens was assessed using X-ray diffraction. The Kruskal-Wallis one-way analysis of variance was used to establish significance (α = 0.05). The fracture resistance of zirconia-based frameworks significantly increases with an increase in the size of alumina particles used for air abrasion: 715.5 N for 250 µm alumina particles, 661.1 N for 110 µm, 608.7 N for 50 µm and the lowest for the untreated specimens (364.2 N). The X-ray diffraction analysis showed an increase in the monoclinic phase content after air abrasion: 50 µm alumina particles-26%, 110 µm-40%, 250 µm-56%, and no treatment-none. Air abrasion of the zirconia-based dental ceramics' surface with alumina particles increases the fracture resistance of zirconia copings and the monoclinic phase volume. This increase is strongly related to the alumina particle size.

4.
J Clin Med ; 12(13)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37445415

RESUMO

BACKGROUND: The mandible is the most injured part of the facial skeleton, and 25-40% of mandibular fractures involve the condyle process. The aim of this study is to answer the question of the relationship between screw pullout and/or plate fracture during osteosynthesis. METHODS: We tested polyurethane models of mandibles whose condylar process was cut (simulating a fracture) and fused using plates and screws. RESULTS: A total of 672 plates were tested. A total of 25.6% of them were fractured during the test, with most being fractures of the base of the condyle. More screws (81.97%) are pulled out from the ramus than from the condyle-69.15%. CONCLUSIONS: The gold standard in the osteosynthesis of condylar fractures is two straight plates. Other than these, there is no one-size-fits-all plate for every type of fracture. Plates fixed with fewer screws (smaller plates used in higher-lying fractures) are more likely to result in screw pullout. On the other hand, in plates fixed with more screws, plate fracture is more common.

5.
J Clin Med ; 12(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37445541

RESUMO

In the surgical treatment of the most common fracture of the mandible, which is a fracture of the condylar base, a great choice of different plate shapes is observed. The aim of this study was to determine which shape gives the greatest fixation stiffness. To ensure homogeneity in comparison, tests were performed on polyurethane models divided at the level of the condylar base fracture and each were fixed with 51 plates. The plates were cut from a 1 mm thick grade 23 titanium sheet. The models were then loaded and the force required for 1 mm of fracture displacement was recorded. It was noted that in addition to osteosynthesis from two simple plates, there were also two dedicated single plates with similar rigidity. Among the large number of described designs of plates, there is considerable variation in terms of the stability of the fixation performed with them. The proposed Mechanical Excellence Factor allows a pre-evaluation of the expected rigidity of fixation with a given plate shape without the need for a loading experiment. The authors expect this to be helpful for surgeons in the application of relevant plates, as well for inventors of new plates for the osteosynthesis of basal fractures in mandibular condyle.

6.
Materials (Basel) ; 14(3)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525369

RESUMO

The successful restoration of teeth requires a good connection between the inlay and natural tissue. A strong bond may improve retention and reinforce tooth structure. The purpose of this study was to evaluate the influence of cement layer thickness on contraction stress generated during photopolymerization, and to determine the changes in stress state of the cement occurring during aging in water (over 84 days). Two cements were used: resin composite cement (NX3) and self-adhesive resin cement (Maxcem Elite Chroma). A cylindrical sample made of CuZn alloy was used to imitate the inlay. The stress state was measured by photoelastic analysis. The contraction stress of the inlay restoration was calculated for cement layer thicknesses of 25 µm, 100 µm, 200 µm, and 400 µm. For both tested materials, the lowest contraction stress was observed for the thinnest layer (25 µm), and this increased with thickness. Following water immersion, a significant reduction in contraction stress was observed due to hygroscopic expansion. Applying a thin layer (approximately 25 µm) of composite and self-adhesive resin cements resulted in high levels of expansion stresses (over -6 MPa) after water aging.

7.
Materials (Basel) ; 14(4)2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33578685

RESUMO

Reconstruction of the facial skeleton is challenging for surgeons because of difficulties in proper shape restoration and maintenance of the proper long-term effect. ZrO2 implant application can be a solution with many advantages (e.g., osseointegration, stability, and radio-opaqueness) and lacks the disadvantages of other biomaterials (e.g., metalosis, radiotransparency, and no osseointegration) or autologous bone (e.g., morbidity, resorption, and low accuracy). We aimed to evaluate the possibility of using ZrO2 implants as a new application of this material for craniofacial bone defect reconstruction. First, osteoblast (skeleton-related cell) cytotoxicity and genotoxicity were determined in vitro by comparing ZrO2 implants and alumina particle air-abraded ZrO2 implants to the following: 1. a titanium alloy (standard material); 2. ultrahigh-molecular-weight polyethylene (a modern material used in orbital surgery); 3. a negative control (minimally cytotoxic or genotoxic agent action); 4. a positive control (maximally cytotoxic or genotoxic agent action). Next, 14 custom in vivo clinical ZrO2 implants were manufactured for post-traumatologic periorbital region reconstruction. The soft tissue position improvement in photogrammetry was recorded, and clinical follow-up was conducted at least 6 years postoperatively. All the investigated materials revealed no cytotoxicity. Alumina particle air-abraded ZrO2 implants showed genotoxicity compared to those without subjection to air abrasion ZrO2, which were not genotoxic. The 6-month and 6- to 8-year clinical results were aesthetic and stable. Skeleton reconstructions using osseointegrated, radio-opaque, personalized implants comprising ZrO2 material are the next option for craniofacial surgery.

8.
Materials (Basel) ; 13(16)2020 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-32785055

RESUMO

Complex dental components which are individually tailored to the patient can be obtained due to new additive manufacturing technology. This paper reviews the metallic powders used in dental applications, the fabrication process (build orientation, process parameters) and post-processing processes (stress relieving, surface finishing). A review of the literature was performed using PubMed, ScienceDirect, Mendeley and Google Scholar. Over eighty articles were selected based on relevance to this review. This paper attempts to include the latest research from 2010 until 2020, however, older manuscripts (10 articles) were also selected. Over 1200 records were identified through the search; these were screened for title and/or summary. Over eighty articles were selected based on relevance to this review. In order to obtain a product which can be used in clinical applications, the appropriate manufacturing parameters should be selected. A discussion was made on optimal selective laser melting (SLM) parameters in dentistry. In addition, this paper includes a critical review of applied thermal treatment methods for Co-Cr alloys used in dentistry.

9.
Materials (Basel) ; 13(8)2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32331209

RESUMO

BACKGROUND: In the literature, no information on plates for low-neck mandibular condylar osteosynthesis can be found, despite the fact that 30 plate designs have already been published. The aim of this study was to compare any dedicated plates for possible use in low-neck condylar fracture osteosynthesis. METHODS: The force required for 1-mm displacement of the fixed fracture fragments and incidents of screw loosening were recorded on polyurethane mandibles among 16 designs of titanium plates fixed by 6-mm screws in a 2.0 system. RESULTS: Double-straight plate fixation was the mechanical gold standard (15.2 ± 3.5 N), followed by A-shape Condylar Plates (14.9 ± 2.1 N), X-shape Condylar Plates (14.2 ± 1.3 N) and Auto Repositioning Plates (11.8 ± 2.4 N). Screw loosening was uncommon, as a minimum of three screws were placed into the condylar part. Fewer screws were lost from the ramus part of the fixation if the plate was attached to the condylar part by three screws. Often, the stability of the ramus screws was lost when there were only two fixing screws in the condyle (p < 0.001). CONCLUSIONS: It is advisable to consider the mechanical advantages as one decides which plate to choose for open rigid internal fixation in low-neck condylar fractures, or to only be aware of the significant differences in mobility within the fracture line after fixation with different dedicated plates.

10.
Materials (Basel) ; 13(3)2020 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-32012777

RESUMO

BACKGROUND: In the literature no information about plates for the high-neck mandibular condylar osteosynthesis could be found despite that 30 plate designs have been published. The main course consider the basal condylar or diacapitular fractures. The aim of the study was to test mechanically all available designs (only 4 of 30 was proper) on polyurethane mandibles using an individually designed clamping system. METHODS: Forces required for a 1 mm displacement of fixed fracture fragments and incidents of screw loosening were recorded. RESULTS: It has occured that dedicated plates for fixation are much weaker than set of two straight plates (p<0.0001). General observation is the bigger plate and more screws, the better rigid stable osteosynthesis of mandibular condyle, however, there are limitations in plates design for high-neck fractures resulted in restricted operation field. CONCLUSION: Double straight plates occured to be the best mechanical fixation for high-neck fractures of the mandibular condyle. Maybe other existing plates could be used but only after prebending or that fracture required novel dedicated plates design.

11.
Polymers (Basel) ; 13(1)2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-33396352

RESUMO

This paper describes a novel method for the experimental validation of numerically optimised turbomachinery components. In the field of additive manufacturing, numerical models still need to be improved, especially with the experimental data. The paper presents the operational characteristics of a compressor wheel, measured during experimental research. The validation process included conducting a computational flow analysis and experimental tests of two compressor wheels: The aluminium wheel and the 3D printed wheel (made of a polymer material). The chosen manufacturing technology and the results obtained made it possible to determine the speed range in which the operation of the tested machine is stable. In addition, dynamic destructive tests were performed on the polymer disc and their results were compared with the results of the strength analysis. The tests were carried out at high rotational speeds (up to 120,000 rpm). The results of the research described above have proven the utility of this technology in the research and development of high-speed turbomachines operating at speeds up to 90,000 rpm. The research results obtained show that the technology used is suitable for multi-variant optimization of the tested machine part. This work has also contributed to the further development of numerical models.

12.
Clin Oral Investig ; 21(5): 1853-1859, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27766488

RESUMO

OBJECTIVE: This study aimed to present a new possibility to create radio-opaque implant material for craniomaxillofacial reconstruction. MATERIALS AND METHODS: The test disks made of the own compound of polyethylenes with addiction of 2, 4, and 6 % of weight TiO2 was investigated for cytotoxicity [each group 15 disks respectively]. Next, computed tomography of the disks was performed in environment of muscle and fat. Hardness, tensile modulus and strength, and compressive modulus and strength were tested too. RESULTS: Deterioration of mechanical properties of the composites containing titanium dioxide was observed [hardness, tensile modulus and strength, compressive modulus and strength, respectively: 56.7 ± 1.6 shore D, 354 ± 52, 22.5 ± 1.3, 21.8 ± 1.1, and 2995 ± 327 MPa as addiction of 2 % TiO2; 52.0 ± 0.9 shore D, 347 ± 66, 18.0 ± 0.7, 14.2 ± 0.9, and 1396 ± 477 MPa as 4 % TiO2; 51.3 ± 1.3 shore D, 316 ± 9, 17.4 ± 0.2, 13.6 ± 0.6, and 1100 ± 144 MPa as 6 % TiO2 added]. The test disks revealed no cytotoxicity effect on human osteoblasts. The new material presents mild radio-opacity which was enough to observe the implant in relation to fat and muscle, but with no visible effect of beam hardening. CONCLUSION: In view of the performed tests, the polyethylene enriched by titanium dioxide seems to be a proper material to consider manufacturing of craniomaxillofacial implants. CLINICAL RELEVANCE: Maxilloafacial surgery is still looking for new implantologic materials. The proposed one is a new way to manufacture an implant visible in computed tomography which does not interfere with its shape in radiological examination and makes it possible to observe the surrounding soft tissues.


Assuntos
Resinas Acrílicas/química , Prótese Maxilofacial , Polietileno/química , Desenho de Prótese , Materiais Dentários/química , Módulo de Elasticidade , Dureza , Humanos , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Titânio/química , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...