Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Hosp Palliat Care ; 39(6): 659-666, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34414798

RESUMO

PURPOSE: Extracorporeal membrane oxygenation (ECMO) is an expensive and scarce life sustaining treatment provided to certain critically ill patients. Little is known about the informed consent process for ECMO or clinician viewpoints on ethical complexities related to ECMO in practice. METHODS: We sent a cross-sectional survey to all departments providing ECMO within 7 United States hospitals in January 2021. One clinician from each department completed the 42-item survey representing their department. RESULTS: Fourteen departments within 7 hospitals responded (response rate 78%, N = 14/18). The mean time spent consenting patients or surrogate decision-makers for ECMO varied, from 7.5 minutes (95% CI 5-10) for unstable patients to 20 minutes (95% CI 15-30) for stable patients (p = 0.0001). Few clinician respondents (29%) report patients or surrogate decision-makers always possess informed consent for ECMO. Most departments (92%) have absolute exclusion criteria for ECMO such as older age (43%, cutoffs ranging from 60-75 years), active malignancy (36%), and elevated body mass index (29%). A significant minority of departments (29%) do not always offer the option to withdraw ECMO to patients or surrogate decision-makers. For patients who cannot be liberated from ECMO and are ineligible for heart or lung transplant, 36% of departments would recommend the patient be removed from ECMO and 64% would continue ECMO support. CONCLUSION: Adequate informed consent for ECMO is a major ethical challenge, and the content of these discussions varies. Use of categorical exclusion criteria and withdrawal of ECMO if a patient cannot be liberated from it differ among departments and institutions.


Assuntos
Oxigenação por Membrana Extracorpórea , Estado Terminal/terapia , Estudos Transversais , Humanos , Estudos Retrospectivos , Inquéritos e Questionários , Estados Unidos
2.
Cartilage ; 10(2): 222-228, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-29338324

RESUMO

OBJECTIVE: To determine biomechanical effects of knee cartilage defect perimeter morphology based on cartilage strain and opposing subchondral bone contact. DESIGN: Articular cartilage defects were created in 5 bovine femoral condyles: group 1, 45° inner bevel with 8-mm rim; group 2, vertical with 8-mm rim; and group 3, 45° outer bevel with 8-mm base. Samples were placed into a custom-machined micro-computed tomography tube and subjected to 800 N of axial loading. DICOM data were used to calculate cartilage thickness 4 and 6 mm from the center, distance between tibial cartilage surface and femoral subchondral bone, and contact width between tibial cartilage and subchondral bone. Strain 4 mm from the center and both absolute and change in distance (mm) to subchondral bone were compared between groups 1 and 2 using paired t tests. Strain at 6 mm and distance changed, loaded distance, and contact width (mm) were compared between groups using the Friedman test with post hoc analysis using Wilcoxon signed rank test. RESULTS: No significant differences in rim strain were noted between groups 1 and 2 at 4 mm ( P = 0.10) and between groups 1, 2, and 3 at 6 mm ( P = 0.247) from the defect center. The loaded distance was significantly different between groups 1 and 3 ( P = 0.013). No significant change in distance to the subchondral bone was found between groups ( P = 0.156). The difference in subchondral bone contact area approached but did not reach significance ( P = 0.074). CONCLUSION: When debriding focal articular cartilage defects, establishment of an inner bevel decreases tissue deformation and contact with opposing subchondral bone.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Joelho de Quadrúpedes/diagnóstico por imagem , Microtomografia por Raio-X , Animais , Fenômenos Biomecânicos , Doenças das Cartilagens/patologia , Doenças das Cartilagens/fisiopatologia , Cartilagem Articular/patologia , Cartilagem Articular/fisiopatologia , Bovinos , Desbridamento , Modelos Animais de Doenças , Fêmur/diagnóstico por imagem , Fêmur/patologia , Fêmur/fisiopatologia , Joelho de Quadrúpedes/patologia , Joelho de Quadrúpedes/fisiopatologia , Tíbia/diagnóstico por imagem , Tíbia/patologia , Tíbia/fisiopatologia , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...