Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomicrofluidics ; 10(5): 054115, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27795747

RESUMO

Cell-cell communication mediates immune responses to physiological stimuli at local and systemic levels. Intercellular communication occurs via a direct contact between cells as well as by secretory contact-independent mechanisms. However, there are few existing methods that allow quantitative resolution of contact-dependent and independent cellular processes in a rapid, precisely controlled, and dynamic format. This study utilizes a high-throughput microfluidic droplet array platform to analyze cell-cell interaction and effector functions at single cell level. Controlled encapsulation of distinct heterotypic cell pairs was achieved in a single-step cell loading process. Dynamic analysis of dendritic cell (DC)-T cell interactions demonstrated marked heterogeneity in the type of contact and duration. Non-stimulated DCs and T cells interacted less frequently and more transiently while antigen and chemokine-loaded DCs and T cells depicted highly stable interactions in addition to transient and sequential contact. The effector function of CD8+ T cells was assessed via cytolysis of multiple myeloma cell line. Variable cell conjugation periods and killing time were detected irrespective of the activation of T cells, although activated T cells delivered significantly higher cytotoxicity. T cell alloreactivity against the target cells was partially mediated by secretion of interferon gamma, which was abrogated by the addition of a neutralizing antibody. These results suggest that the droplet array-based microfluidic platform is a powerful technique for dynamic phenotypic screening and potentially applicable for evaluation of novel cell-based immunotherapeutic agents.

2.
Lab Chip ; 16(3): 497-505, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26686985

RESUMO

Here we describe a robust, microfluidic technique to generate and analyze 3D tumor spheroids, which resembles tumor microenvironment and can be used as a more effective preclinical drug testing and screening model. Monodisperse cell-laden alginate droplets were generated in polydimethylsiloxane (PDMS) microfluidic devices that combine T-junction droplet generation and external gelation for spheroid formation. The proposed approach has the capability to incorporate multiple cell types. For the purposes of our study, we generated spheroids with breast cancer cell lines (MCF-7 drug sensitive and resistant) and co-culture spheroids of MCF-7 together with a fibroblast cell line (HS-5). The device has the capability to house 1000 spheroids on chip for drug screening and other functional analysis. Cellular viability of spheroids in the array part of the device was maintained for two weeks by continuous perfusion of complete media into the device. The functional performance of our 3D tumor models and a dose dependent response of standard chemotherapeutic drug, doxorubicin (Dox) and standard drug combination Dox and paclitaxel (PCT) was analyzed on our chip-based platform. Altogether, our work provides a simple and novel, in vitro platform to generate, image and analyze uniform, 3D monodisperse alginate hydrogel tumors for various omic studies and therapeutic efficiency screening, an important translational step before in vivo studies.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Neoplasias da Mama , Técnicas de Cultura de Células , Técnicas Analíticas Microfluídicas , Modelos Biológicos , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Sobrevivência Celular , Ensaios de Seleção de Medicamentos Antitumorais/instrumentação , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Feminino , Humanos , Células MCF-7 , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Esferoides Celulares
3.
Lab Chip ; 15(23): 4441-50, 2015 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26456240

RESUMO

Acquired drug resistance is a key factor in the failure of chemotherapy. Due to intratumoral heterogeneity, cancer cells depict variations in intracellular drug uptake and efflux at the single cell level, which may not be detectable in bulk assays. In this study we present a droplet microfluidics-based approach to assess the dynamics of drug uptake, efflux and cytotoxicity in drug-sensitive and drug-resistant breast cancer cells. An integrated droplet generation and docking microarray was utilized to encapsulate single cells as well as homotypic cell aggregates. Drug-sensitive cells showed greater death in the presence or absence of Doxorubicin (Dox) compared to the drug-resistant cells. We observed heterogeneous Dox uptake in individual drug-sensitive cells while the drug-resistant cells showed uniformly low uptake and retention. Dox-resistant cells were classified into distinct subsets based on their efflux properties. Cells that showed longer retention of extracellular reagents also demonstrated maximal death. We further observed homotypic fusion of both cell types in droplets, which resulted in increased cell survival in the presence of high doses of Dox. Our results establish the applicability of this microfluidic platform for quantitative drug screening in single cells and multicellular interactions.


Assuntos
Doxorrubicina/farmacologia , Resistencia a Medicamentos Antineoplásicos/efeitos dos fármacos , Dispositivos Lab-On-A-Chip , Terapia de Alvo Molecular/métodos , Fenótipo , Transporte Biológico , Divisão Celular/efeitos dos fármacos , Doxorrubicina/metabolismo , Fluoresceínas/metabolismo , Humanos , Células MCF-7 , Análise de Célula Única
4.
Talanta ; 75(2): 564-71, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371922

RESUMO

We present herein an effective and versatile method to fabricate a micro-patterned structure of conductive polymer, poly(pyrrole-benzophenone), on Indium Tin Oxide (ITO) glass chips for the subsequent photo-immobilization of various bioreceptor, antigens. Such methodologies are based on photolithography of ITO pattern fabrication on non-conductive surfaces, glass slides, and on a photo-active electrogenerated polymer films. The photo-active polymer serves as a substrate platform for the photo-immobilization of the bioreceptor reagents used for subsequent immunoreactions. We were able to show the resolution of electropolymerization on an ITO pattern as well as immobilization of more than one bioreceptor for the simultaneous detection of several analytes. The antigen micro-arrays were tested for sensitivity, specificity, and overall practicality for the simultaneous detection of analyte anti-Cholera Toxin B, anti-Hepatitis B virus surface and core protein antibodies. In addition we used our pattern ITO-poly(pyrrole-benzophenone) micro-array for the detection of serum samples of Hepatitis B virus patients previously screened by a standard hospital detection method.


Assuntos
Vidro , Luz , Polímeros/química , Receptores de Superfície Celular/química , Anticorpos Anti-Hepatite B/análise , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência
5.
Sens Actuators B Chem ; 122(2): 578-586, 2007 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-32288238

RESUMO

We describe herein a newly developed optical immunosensor for detection of antibodies directed against antigens of the Ebola virus strains Zaire and Sudan. We employed a photo immobilization methodology based on a photoactivatable electrogenerated poly(pyrrole-benzophenone) film deposited upon an indium tin oxide (ITO) modified conductive surface fiber-optic. It was then linked to a biological receptor, Ebola virus antigen in this case, on the fiber tip through a light driven reaction. The photochemically modified optical fibers were tested as an immunosensor for detection of antibodies against Ebola virus, in animal and human sera, by use of a coupled chemiluminescent reaction. The immunosensor was tested for sensitivity, specificity, and compared to standard chemiluminescent ELISA under the same conditions. The analyte, anti-Ebola IgG, was detected at a low titer of 1:960,000 and 1:1,000,000 for subtypes Zaire and Sudan, respectively. While the same serum tested by ELISA was one order (24 times) less sensitive.

6.
Anal Chem ; 77(6): 1771-9, 2005 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15762584

RESUMO

We describe herein a newly developed optical microbiosensor for the diagnosis of hepatitis C virus (HCV) by using a novel photoimmobilization methodology based on a photoactivable electrogenerated polymer film deposited upon surface-conductive fiber optics, which are then used to link a biological receptor to the fiber tip through light mediation. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide on the silica surface of the fiber optics. Monomers are then electropolymerized onto the conductive metal oxide surface; thereafter, the fibers are immersed in a solution containing HCV-E2 envelope protein antigen and illuminated with UV light (wavelength approximately 345 nm). As a result of the photochemical reaction, a thin layer of the antigen becomes covalently bound to the benzophenone-modified surface. The photochemically modified fiber optics were tested as immunosensors for the detection of anti-E2 protein antibody analyte that was measured through chemiluminescence reaction. The biosensor was tested for sensitivity, specificity, and overall practicality. Our results suggest that the detection of anti-E2 antibodies with this microbiosensor may enhance significantly HCV serological standard testing especially among patients during dialysis, which were diagnosed as HCV negative, by standard immunological tests, but were known to carry the virus. If transformed into an easy to use procedure, this assay might be used in the future as an important clinical tool for HCV screening in blood banks.


Assuntos
Benzofenonas/química , Técnicas Biossensoriais/métodos , Hepacivirus/isolamento & purificação , Anticorpos Anti-Hepatite C/sangue , Proteínas do Envelope Viral/imunologia , Ensaio de Imunoadsorção Enzimática , Tecnologia de Fibra Óptica , Humanos , Fibras Ópticas , RNA Viral/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...