1.
Sensors (Basel) ; 21(20)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34696048

RESUMO

The primary goal of this study is to develop a mathematical model that can establish a transfer function relationship between the "external" pulse pressures measured by a tonometer and the "internal" pulse pressure in the artery. The purpose of the model is to accurately estimate and rebuild the internal pulse pressure waveforms using arterial tonometry measurements. To develop and validate a model without human subjects and operators for consistency, this study employs a radial pulse generation system, a robotic tonometry system, and a write model with an artificial skin and vessel. A transfer function model is developed using the results of the pulse testing and the mechanical characterization testing of the skin and vessel. To evaluate the model, the pulse waveforms are first reconstructed for various reference pulses using the model with tonometry data. They are then compared with pulse waveforms acquired by internal measurement (by the built-in pressure sensor in the vessel) the external measurement (the on-skin measurement by the robotic tonometry system). The results show that the model-produced pulse waveforms coinciding well with the internal pulse waveforms with small relative errors, indicating the effectiveness of the model in reproducing the actual pulse pressures inside the vessel.


Assuntos
Procedimentos Cirúrgicos Robóticos , Pressão Sanguínea , Determinação da Pressão Arterial , Frequência Cardíaca , Humanos , Manometria , Pulso Arterial , Artéria Radial
2.
J Healthc Eng ; 2019: 4938063, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30886685

RESUMO

To meet the need for "standard" testing system for wearable blood pressure sensors, this study intends to develop a new radial pulsation simulator that can generate age-dependent reference radial artery pressure waveforms reflecting the physiological characteristics of human cardiovascular system. To closely duplicate a human cardiovascular system, the proposed simulator consists of a left ventricle simulation module, an aorta simulation module, a peripheral resistance simulation module, and a positive/negative pressure control reservoir module. Simulating physiologies of blood pressure, the compliance chamber in the simulator can control arterial stiffness to produce age-dependent pressure waveforms. The augmentation index was used to assess the pressure waveforms generated by the simulator. The test results show that the simulator can generate and control radial pressure waveforms similar to human pulse signals consisting of early systolic pressure, late systolic pressure, and dicrotic notch. Furthermore, the simulator's left ventricular pressure-volume loop results demonstrate that the simulator exhibits mechanical characteristics of the human cardiovascular system. The proposed device can be effectively used as a "standard" radial artery pressure simulator to calibrate the wearable sensor's measurement characteristics and to develop more advanced sensors. The simulator is intended to serve as a platform for the development, performance verification, and calibration of wearable blood pressure sensors. It will contribute to the advancement of the wearable blood pressure sensor technology, which enables real-time monitoring of users' radial artery pressure waveforms and eventually predicting cardiovascular diseases.


Assuntos
Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Modelos Cardiovasculares , Artéria Radial/fisiologia , Adulto , Simulação por Computador , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Pulso Arterial/instrumentação , Processamento de Sinais Assistido por Computador , Adulto Jovem
3.
Biomed Eng Online ; 18(1): 1, 2019 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-30602383

RESUMO

BACKGROUND: There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-follower mechanism controlled by a DC motor. The simulator is intended to generate pulse waveforms for a range of pulse pressures and heart beats that are realistic to human blood pulsations. METHODS: This study first performed in vivo testing of a healthy young man to collect his pulse waveforms using a robotic tonometry system (RTS). Based on the collected data a representative human radial pulse waveform is obtained by conducting a mathematical analysis. This standard pulse waveform is then used to design the cam profile. Upon fabrication of the cam, the pulsatile simulator, consisting of the pulse pressure generating component, pressure and heart rate adjusting units, and the real-time pulse display, is constructed. Using the RTS, a series of testing was performed on the prototype to collect its pulse waveforms by varying the pressure levels and heart rates. Followed by the testing, the pulse waveforms generated by the prototype are compared with the representative, in vivo, pulse waveform. RESULTS: The radial Augmentation Index analysis results show that the percent error between the simulator data and human pulse profiles is sufficiently small, indicating that the first two peak pressures agree well. Moreover, the phase analysis results show that the phase delay errors between the pulse waveforms of the prototype and the representative waveform are adequately small, confirming that the prototype simulator is capable of simulating realistic human pulse waveforms. CONCLUSIONS: This study demonstrated that a very accurate radial pressure waveform can be reproduced using the cam-based simulator. It can be concluded that the same testing and design methods can be used to generate pulse waveforms for other age groups or any target pulse waveforms. Such a simulator can make a contribution to the research efforts, such as development of wearable pressure sensors, standardization of pulse diagnosis in oriental medicine, and training medical professionals for pulse diagnosis techniques.


Assuntos
Engenharia Biomédica/instrumentação , Pressão Sanguínea/fisiologia , Frequência Cardíaca , Artéria Radial/fisiologia , Engenharia Biomédica/métodos , Doenças Cardiovasculares/fisiopatologia , Simulação por Computador , Desenho de Equipamento , Análise de Fourier , Humanos , Manometria , Pressão , Pulso Arterial , Robótica , Processamento de Sinais Assistido por Computador , Adulto Jovem
4.
Rev Sci Instrum ; 88(5): 055103, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28571442

RESUMO

This paper presents a novel Magneto-rheological (MR) brake system that can self-regulate the output braking torques. The proposed MR brake can generate a braking torque at a critical rotation speed without an external power source, sensors, or controllers, making it a simple and cost-effective device. The brake system consists of a rotary disk, permanent magnets, springs, and MR fluid. The permanent magnets are attached to the rotary disk via the springs, and they move outward through grooves with two different gap distances along the radial direction of the stator due to the centrifugal force. Thus, the position of the magnets is dependent on the spin speed, and it can determine the magnetic fields applied to MR fluids. Proper design of the stator geometry gives the system unique torque characteristics. To show the performance of an MR brake system, the electromagnetic characteristics of the system are analyzed, and the torques generated by the brake are calculated using the result of the electromagnetic analysis. Using a baseline model, a parametric study is conducted to investigate how the design parameters (geometric shapes and material selection) affect the performance of the brake system. After the simulation study, a prototype brake system is constructed and its performance is experimentally evaluated. The experimental results show that the prototype produced the maximum torque of 1.2 N m at the rotational speed of 100 rpm. The results demonstrate the feasibility of the proposed MR brake as a speed regulator in rotating systems.

5.
Rev Sci Instrum ; 88(3): 035004, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372429

RESUMO

Haptic display units have been widely used for conveying button sensations to users, primarily employing vibrotactile actuators. However, the human feeling for pressing buttons mainly relies on kinaesthetic sensations (rather than vibrotactile sensations), and little studies exist on small-scale kinaesthetic haptic units. Thus, the primary goals of this paper are to design a miniature kinaesthetic actuator based on Magneto-Rheological (MR) fluid that can convey various button-clicking sensations and to experimentally evaluate its haptic performance. The design focuses of the proposed actuator were to produce sufficiently large actuation forces (resistive forces) for human users in a given size constraint and to offer a wide range of actuation forces for conveying vivid haptic sensations to users. To this end, this study first performed a series of parametric studies using mathematical force models for multiple operating modes of MR fluid in conjunction with finite element electromagnetism analysis. After selecting design parameters based on parametric studies, a prototype actuator was constructed, and its performance was evaluated using a dynamic mechanical analyzer. It measured the actuator's resistive force with a varying stroke (pressed depth) up to 1 mm and a varying input current from 0 A to 200 mA. The results show that the proposed actuator creates a wide range of resistive forces from around 2 N (off-state) to over 9.5 N at 200 mA. In order to assess the prototype's performance in the terms of the haptic application prospective, a maximum force rate was calculated to determine just noticeable difference in force changes for the 1 mm stoke of the actuator. The results show that the force rate is sufficient to mimic various levels of button sensations, indicating that the proposed kinaesthetic actuator can offer a wide range of resistive force changes that can be conveyed to human operators.

6.
Rev Sci Instrum ; 83(4): 046108, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559594

RESUMO

An adaptive tunable vibration absober based on magnetorheological elastomer (MRE) is designed as an intelligent device for auto-tuning itself to the time-varying harmonic disturbance force to reduce the unwanted vibration of the primary system in the steady state. The objectives of this note are to develop and implement a continuous control method for a MRE tunable vibration absorber (TVA) and to evaluate its performance in suppressing time-varying tonal vibrations. In the proposed control, the stiffness of MREs is continuously varied based on a nonlinear tuning function that relates the response of the system to the input magnetic field density. Through experiments, it will be shown that the proposed MRE TVA reduces in real time the transmission of a time-varying excited vibration of 48-55 Hz, which shows the potential applicability of the MRE in reducing unwanted vibration to precision devices.