Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Hand Surg Am ; 48(7): 691-698, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37191605

RESUMO

PURPOSE: In treatment of mallet finger fractures (MFFs), the aim is to minimize residual extension lag, reduce subluxation, and restore congruency of the distal interphalangeal (DIP) joint. Failure to do so may increase the risk of secondary osteoarthritis (OA). However, long-term follow-up studies focusing on OA of the DIP joint after an MFF are scarce. The purpose of this study was to assess OA, functional outcomes, and patient-reported outcome measures (PROMs) after an MFF. METHODS: A cohort study was performed with 52 patients who sustained an MFF at a mean of 12.1 years (range, 9.9-15.5 years) previously and who were treated nonsurgically. A healthy contralateral DIP joint was used as the control. Outcomes were radiographic OA, using the Kellgren and Lawrence and Osteoarthritis Research Society International classifications, range of motion, pinch strength, and PROMs (Patient-Rated Wrist Hand Evaluation, Quick Disabilities of the Arm, Shoulder, and Hand, Michigan Hand Outcome Questionnaire, 12-item Short Form Health Survey). Radiographic OA was correlated with PROMs and functional outcomes. RESULTS: At follow-up, there was an increase in OA in 41% to 44% of the MFFs. Of all the MFFs, 23% to 25% showed a higher degree of OA than the healthy control DIP joint. Range of motion (mean difference ranging from -6° to -14°) and Michigan Hand Outcome Questionnaire score (median difference, -1.3) were decreased after MFFs but not to a clinically relevant extent. Radiographic OA was weakly to moderately correlated with functional outcomes and PROMs. CONCLUSIONS: Radiological OA after an MFF is similar to the natural degenerative process in the DIP joint and is accompanied by a decrease in range of motion of the DIP joint, which does not clinically affect PROMs. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Traumatismos dos Dedos , Fraturas Ósseas , Deformidades Adquiridas da Mão , Osteoartrite , Traumatismos dos Tendões , Humanos , Seguimentos , Estudos de Coortes , Estudos Retrospectivos , Articulações dos Dedos/cirurgia , Fraturas Ósseas/cirurgia , Traumatismos dos Dedos/diagnóstico por imagem , Traumatismos dos Dedos/terapia , Osteoartrite/diagnóstico por imagem , Osteoartrite/etiologia , Osteoartrite/terapia , Deformidades Adquiridas da Mão/cirurgia , Amplitude de Movimento Articular
3.
BMC Musculoskelet Disord ; 21(1): 374, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32532306

RESUMO

BACKGROUND: To evaluate the reliability of two different techniques for measuring penetration and distribution of the cement mantle in the proximal tibia after total knee arthroplasty (TKA) with Computer Tomography (CT) in vivo. METHODS: Standardized CT scans of the proximal tibia were taken 1 to 2 years after total knee arthroplasties implanted with a surface cementing technique. These prospectively acquired transversal CT images of the surface of the proximal tibia were divided into four quadrants and were assessed once manually and once with a numerical computing program (MATLAB® Update 2, The MathWorks, Inc.) based on Hounsfield Units by one of the researchers. The assessments were repeated by the same and a second researcher. The ratio cement/trabecular bone was calculated 1, 3 and 5 mm distal of the tibia tray per quadrant. Kruskall-Wallis tests with multiple pairwise comparisons (Dunn's test) were used to determine differences between the quadrants. Intra- and inter-rater reliability as well as the inter method reliability were assessed with the Intraclass Correlation Coefficient (ICC) per level of depth and with Bland-Altman plots. RESULTS: A total of 92 CT scans were included. The intra- and inter-rater reliability of the manual method ranged from 0.22 and 0.52. The intra- and inter-rater reliability of the matlab method varied between 0.98 to 0.99. The median percentage cement measured with the matlab method 1 mm underneath the tibial tray varied between 82 and 88%; at 3 mm depth between 38 and 54% and at 5 mm between 15 and 25%. There was significantly (p < 0.05) less cement in the antero-medial quadrant compared to the antero-lateral and postero-lateral quadrant at 3 mm and 5 mm depth. CONCLUSIONS: Distribution and penetration of cement in the proximal tibia in a total knee arthroplasty can be measured reliably with CT in combination with the matlab method presented in this manuscript. This method can be used for clinical purposes as well as for scientific research. TRIAL REGISTRATION: METC-nr: 06-104 Dossier NL14807.098.06/versie 06.


Assuntos
Artroplastia do Joelho/métodos , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cimentos Ósseos , Cimentação/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...