Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38917274

RESUMO

We introduce a new ionization technique for compact, portable mass spectrometers. It consists of a syringe with sample liquid capped by a self-ionizing spray nozzle containing a microfabricated nozzle chip. Interaction of the sample liquid with the nozzle wall results in electrical charging without the need for electronics. Elaborate cleaning procedures are redundant when disposable syringes and mass-fabricated spray nozzles are used. This self-named electroless spray ionization (ELI) technique shows comparable performance to conventional ionization techniques. In contrast to commonly used electrospray ionization, ELI exhibits excellent ionization efficiency for low-conductive solutions such as water or acetonitrile. Due to its compact size and the absence of high-voltage electronics, it can also be readily integrated in other ionization sources. Besides reviewing the main properties of ELI, we showcase the technique's potential for two on-site, ambient mass spectroscopy applications: perfume fingerprinting and fast screening of fungicides on citrus fruits.

2.
J Adv Res ; 44: 227-232, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36725192

RESUMO

INTRODUCTION: The characterisation of nasal formulations is a critical point. However, there are still no recommendations or guidelines in terms of standard approaches for evaluating the formulation's nasal deposition and/or coverage profile. This study optimises a method for quantifying silicone nasal cast deposition and coverage of liquid formulations using different nasal devices. OBJECTIVES: The present work investigates the nasal deposition and coverage patterns of innovative nasal spray nozzles producing slow velocity soft mists, using a nasal cavity replica and a fluorescent dye. METHODS: The study of the deposition pattern of a fluorescent liquid formulation in a transparent nasal cast was carried out in both the presence and absence of a simulated inhalation flow. The extent of the deposition pattern was investigated using ImageJ and fluorescence in the nasal cast, quantified by fluorometric analysis. The particle size distribution and initial droplet velocity were determined using a laser diffractometer and a high-speed camera with a frame rate of 1000 fps. RESULTS: A uniform intranasal coverage was obtained with droplets of a volume median particle size (Dv50) between 15 and 25 µm in airflow between 10 and 30 L/min. In these conditions, aerosol formulations can be uniformly deposited in the vestibule and turbinate cavity nasal regions, with less than 10 % passing beyond the nasopharyngeal region. CONCLUSION: The method applied allowed for the determination of the coverage of the nasal cast in different regions using images analysis and fluorometric analysis. Droplet velocity is a critical parameter in the deposition in the nasal cavity. With standard swirl nozzles, many droplets are found on the surface of the nasal vestibule. Soft mist nozzles produce smaller droplets at a much lower initial velocity (<1 m/s), resulting in a more uniform coverage.


Assuntos
Silicones , Conchas Nasais , Composição de Medicamentos , Administração Intranasal , Aerossóis
3.
Pharmaceutics ; 16(1)2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276480

RESUMO

Currently, nasal administration of active pharmaceutical ingredients is most commonly performed using swirl-nozzle-based pump devices or pressurized syringes. However, they lead to limited deposition in the more active regions of the nasal cavity, especially the olfactory region, which is crucial for nose-to-brain drug delivery. This research proposes to improve deposition in the olfactory region by replacing the swirl nozzle with a nanoengineered nozzle chip containing micrometer-sized holes, which generates smaller droplets of 10-50 µm travelling at a lower plume velocity. Two nanotech nozzle chips with different hole sizes were tested at different inhalation flow rates to examine the deposition patterns of theophylline, a hyposmia treatment formulation, using a nasal cavity model. A user study was also conducted and showed that the patient instructions influenced the inhalation flow rate characteristics. Targeted flow rates of between 0 and 25 L/min were used for the in vitro deposition study, yielding 21.5-31.5% olfactory coverage. In contrast, the traditional swirl nozzle provided only 10.8% coverage at a similar flow rate. This work highlights the potential of the nanotech soft mist nozzle for improved intranasal drug delivery, particularly to the olfactory region.

4.
Sci Rep ; 12(1): 19296, 2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36369251

RESUMO

The charging of poorly conducting liquids due to flows is a well-known phenomenon, yet the precise charging mechanism is not fully understood. This is especially relevant for sprays, where the spray plume dynamics and maximum distance travelled of a spray dramatically changes for different levels of charging: charging of the droplets makes them repel, thereby preventing drop coalescence and altering the shape of the spray plume. As the charging depends on many factors including the flow and the interactions between the liquid and the nozzle, many models and scaling laws exist in the literature. In this work we focus on perhaps the simplest flow regime, laminar jets created by ultra short channels, and quantify the charging as a function of the different parameters. We present a simple model that collapses all the data for over 4 orders of magnitude difference in streaming currents for various nozzle sizes, flow velocities and surface treatments. We further show that the charging polarity can even be reversed by applying an oppositely charged coating to the nozzle, an important step for any application.

5.
Build Environ ; 220: 109254, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35719131

RESUMO

Cardiac exercise stress testing (CEST) is an important diagnostic tool in daily cardiology practice. However, during intense physical activity microdroplet aerosols, potentially containing SARS-CoV-2 particles, can persist in a room for a long time. This poses a potential infection risk for the medical staff involved in CEST, as well as for the patients entering the same room afterwards. We measured aerosol generation and persistence, to perform a risk assessment for SARS-CoV-2 transmission through aerosols during CEST. We find that during CEST, the aerosol levels remain low enough that SARS-CoV-2 transmission through aerosols is unlikely, with the room ventilation system producing 14 air changes per hour. A simple measurement of CO2 concentration gives a good indication of the ventilation quality.

6.
Soft Matter ; 18(5): 999-1004, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35015010

RESUMO

We investigate the process of the slow unrolling of a roll of typical pressure-sensitive adhesive, Scotch tape, under its own weight. Probing the peeling velocities down to nm s-1 resolution, which is three orders of magnitudes lower than earlier measurements, we find that the speed is still non-zero. Moreover, the velocity is correlated to the relative humidity. A humidity increase leads to water uptake, making the adhesive weaker and easier to peel. At very low humidity, the adhesive becomes so stiff that it mainly responds elastically, leading to a peeling process akin to interfacial fracture. We provide a quantitative understanding of the peeling velocity in the two regimes.

7.
Nat Commun ; 12(1): 2521, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33947855

RESUMO

Anyone who has ever broken a dish or a glass knows that the resulting fragments range from roughly the size of the object all the way down to indiscernibly small pieces: typical fragment size distributions of broken brittle materials follow a power law, and therefore lack a characteristic length scale. The origin of this power-law behavior is still unclear, especially why it is such an universal feature. Here we study the explosive fragmentation of glass Prince Rupert's drops, and uncover a fundamentally different breakup mechanism. The Prince Rupert's drops explode due to their large internal stresses resulting in an exponential fragment size distribution with a well-defined fragment size. We demonstrate that generically two distinct breakup processes exist, random and hierarchical, that allows us to fully explain why fragment size distributions are power-law in most cases but exponential in others. We show experimentally that one can even break the same material in different ways to obtain either random or hierarchical breakup, giving exponential and power-law distributed fragment sizes respectively. That a random breakup process leads to well-defined fragment sizes is surprising and is potentially useful to control fragmentation of brittle solids.

8.
Respir Care ; 66(6): 891-896, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33536316

RESUMO

BACKGROUND: There is a persistent concern over the risk of respiratory pathogen transmission, including SARS-CoV-2, via the formation of aerosols (ie, a suspension of microdroplets and residual microparticles after evaporation) generated during high-flow nasal cannula (HFNC) oxygen therapy in critically ill patients. This concern is fueled by limited available studies on this subject. In this study, we tested our hypothesis that HFNC treatment is not associated with increased aerosol formation as compared to conventional oxygen therapy. METHODS: We used laser light scattering and a handheld particle counter to detect and quantify aerosols in healthy subjects and in adults with acute respiratory disease, including COVID-19, during HFNC or conventional oxygen therapy. RESULTS: The use of HFNC was not associated with increased formation of aerosols as compared to conventional oxygen therapy in both healthy subjects (n = 3) and subjects with acute respiratory disease, including COVID-19 (n = 17). CONCLUSIONS: In line with scarce previous clinical and experimental findings, our results indicate that HFNC itself does not result in overall increased aerosol formation as compared to conventional oxygen therapy. This suggests there is no increased risk of respiratory pathogen transmission to health care workers during HFNC.


Assuntos
COVID-19 , Ventilação não Invasiva , Insuficiência Respiratória , Adulto , Aerossóis , Cânula , Estado Terminal , Humanos , Oxigenoterapia , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , SARS-CoV-2
9.
Phys Fluids (1994) ; 32(12): 121707, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33362399

RESUMO

We measure aerosol persistence to assess the risk of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in public spaces. Direct measurement of aerosol concentrations, however, has proven to be technically difficult; we propose the use of handheld particle counters as a novel and easily applicable method to measure aerosol concentrations. This allows us to perform measurements in typical public spaces, each differing in volume, the number of people, and the ventilation rate. These data are used to estimate the relation between the aerosol persistence time and the risk of infection with SARS-CoV-2.

10.
Phys Fluids (1994) ; 32(10): 107108, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33154612

RESUMO

Transmission of SARS-CoV-2 leading to COVID-19 occurs through exhaled respiratory droplets from infected humans. Currently, however, there is much controversy over whether respiratory aerosol microdroplets play an important role as a route of transmission. By measuring and modeling the dynamics of exhaled respiratory droplets, we can assess the relative contribution of aerosols to the spreading of SARS-CoV-2. We measure size distribution, total numbers, and volumes of respiratory droplets, including aerosols, by speaking and coughing from healthy subjects. Dynamic modeling of exhaled respiratory droplets allows us to account for aerosol persistence times in confined public spaces. The probability of infection by inhalation of aerosols when breathing in the same space can then be estimated using current estimates of viral load and infectivity of SARS-CoV-2. The current known reproduction numbers show a lower infectivity of SARS-CoV-2 compared to, for instance, measles, which is known to be efficiently transmitted through the air. In line with this, our study of transmission of SARS-CoV-2 suggests that aerosol transmission is a possible but perhaps not a very efficient route, in particular from non-symptomatic or mildly symptomatic individuals that exhibit low viral loads.

13.
Phys Rev E ; 100(4-1): 042609, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31770889

RESUMO

Athermal elastic moduli of soft-sphere packings are known to exhibit universal scaling properties near the unjamming point, most notably the vanishing of the shear-to-bulk moduli ratio G/B upon decompression. Interestingly, the smallness of G/B stems from the large nonaffinity of deformation-induced displacements under shear strains, compared to insignificant nonaffinity of displacements under compressive strains. In this work, we show using numerical simulations that the relative weights of the affine and nonaffine contributions to the bulk modulus, and their dependence on the proximity to the unjamming point, can differ qualitatively between different models that feature the same generic unjamming phenomenology. In canonical models of unjamming, we observe that the ratio of the nonaffine to total bulk moduli B_{na}/B approaches a constant upon decompression, while in other, less well-studied models, it vanishes. We show that the vanishing of B_{na}/B in noncanonical models stems from the emergence of an invariance of net (zero) forces on the constituent particles to compressive strains at the onset of unjamming. We provide a theoretical scaling analysis that fully explains our numerical observations, and allows us to predict the scaling behavior of B_{na}/B upon unjamming, given the functional form of the pairwise interaction potential.

14.
Langmuir ; 35(32): 10453-10460, 2019 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-31291117

RESUMO

Evaporation of surfactant-laden sessile droplets is omnipresent in nature and industrial applications such as inkjet printing. Soluble surfactants start to form micelles in an aqueous solution for surfactant concentrations exceeding the critical micelle concentration (CMC). Here, the evaporation of aqueous sodium dodecyl sulfate (SDS) sessile droplets on hydrophobic surfaces was experimentally investigated for SDS concentrations ranging from 0.025 to 1 CMC. In contrast to the constant contact angle of an evaporating sessile water droplet, we observed that, at the same surface, the contact angle of an SDS laden droplet with concentration below 0.5 CMC first decreases, then increases, and finally decreases, resulting in a local contact angle minimum. Surprisingly, the minimum contact angle was found to be substantially lower than the static receding contact angle and decreased with decreasing initial SDS concentration. Furthermore, the bulk SDS concentration at the local contact angle minimum was found to decrease with decrease in the initial SDS concentration. The location of the observed contact angle minimum relative to the normalized evaporation time and its minimum value proved to be independent of both the relative humidity and droplet volume and thus of the total evaporation time. We discuss the observed contact angle dynamics in terms of the formation of a disordered layer of SDS molecules on the substrate at concentrations below 0.5 CMC. The present work underlines the complexity of the evaporation of sessile liquid-surfactant droplets and the influence of surfactant-substrate interactions on the evaporation process.

15.
Sci Rep ; 9(1): 6128, 2019 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-30992484

RESUMO

In many applications where small, similar-sized droplets are needed, ultrasonic nebulizers are employed. Little is known about the mechanism of nebulization, for example about what determines the median droplet size. Even less understood, is the droplet size distribution, which is often simply fitted with a log-normal distribution or assumed to be very narrow. We perform the first systematic study of droplet size distributions for different nebulizer technologies, showing that these distributions can be very well fitted with distributions found for sprays, where the size distribution is completely determined by the corrugation of ligaments and the distribution of ligament sizes. In our case, breakup is believed to be due to pinch-off of Faraday instabilities. The droplet size distribution is then set by the distribution of wavelengths of the standing capillary waves and the roughness of the pinch-off ligaments. We show that different nebulizer technologies produce different size distributions, which we relate to (variation in) wavelengths of the waves that contribute to the droplet formation. We further show that the median droplet size scales with the capillary wavelength, with a proportionality constant that depends only slightly on the type of nebulizer, despite order-of-magnitude differences in other parameters.

16.
Phys Rev E ; 95(6-1): 062141, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28709333

RESUMO

Canonical models for studying the unjamming scenario in systems of soft repulsive particles assume pairwise potentials with a sharp cutoff in the interaction range. The sharp cutoff renders the potential nonanalytic but makes it possible to describe many properties of the solid in terms of the coordination number z, which has an unambiguous definition in these cases. Pairwise potentials without a sharp cutoff in the interaction range have not been studied in this context, but should in fact be considered to understand the relevance of the unjamming phenomenology in systems where such a cutoff is not present. In this work we explore two systems with such interactions: an inverse power law and an exponentially decaying pairwise potential, with the control parameters being the exponent (of the inverse power law) for the former and the number density for the latter. Both systems are shown to exhibit the characteristic features of the unjamming transition, among which are the vanishing of the shear-to-bulk modulus ratio and the emergence of an excess of low-frequency vibrational modes. We establish a relation between the pressure-to-bulk modulus ratio and the distance to unjamming in each of our model systems. This allows us to predict the dependence of other key observables on the distance to unjamming. Our results provide the means for a quantitative estimation of the proximity of generic glass-forming models to the unjamming transition in the absence of a clear-cut definition of the coordination number and highlight the general irrelevance of nonaffine contributions to the bulk modulus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...