Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cardiovasc. revasc. med ; Cardiovasc. revasc. med;20(5): 392-398, May 2019. ilus, tab
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1006900

RESUMO

Introduction and objective: The edge vascular response (EVR) remains unknown in second generation drugeluting Resorbable Magnesium Scaffold (RMS), such as Magmaris. The aim of the study was to evaluate tissue modifications in the RMS edges over time, assessed by different invasive imaging modalities. Methods: The patients treated with the device were assessed by optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS at baseline and 12 months. The EVR study performed a segment- and frame-level analysis of the 5 mm segments proximal and distal of the actual RMS. Results: The segment-level grayscale IVUS (n=10), virtual histology IVUS (n=10), and OCT (n=18) analysis did not showany significant changes after 12months, except for a fibrous plaque area (FPA) reduction of 0.5mm2 (p=0.017) in the proximal segment compared to baseline. In the frame-level analysis, IVUS evaluation revealed a vessel area decreased 2.80 ± 1.43 mm2 (p = 0.012) and 2.49 ± 1.53 mm2 (p = 0.022) in 2 proximal frames. This was accompanied by plaque area reduction of 0.88 ± 0.70 mm2 (p = 0.048) and a FPA decreased by 0.63 ± 0.48mm2 (p = 0.004) in one proximal frame. In 1 distal frame, there was a dense calcium area reduction of 0.10 ± 0.12 mm2 (p = 0.045), FPA and fibrous fatty plaque increased 0.54 ± 0.53 mm2 (p = 0.023) and 0.17 ± 0.16 mm2 (p = 0.016), respectively. By OCT, there was a lumen area decrease of 0.76 ± 1.51 mm2 (p = 0.045) in a distal frame. Conclusion: At 12 months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment. This could be translated as a benign healing process a the edges of the RMS. Summary: The edge vascular response (EVR) remains unknown in second generation drug-eluting absorbable metal scaffolds (RMS), such as Magmaris. Patients treated with the device were assessed by multi invasive imagingmodalities [i.e. optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS] evaluating the tissue changes over timein the segment- and frame-level analysis of the 5mm segments proximal and distal of the actual RMS. As a result, after 12months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment, translating a benign healing process at the edges of the RMS.


Assuntos
Humanos , Ultrassonografia de Intervenção , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA