Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arrhythm ; 40(2): 333-341, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586856

RESUMO

Background: His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) emerge as better alternatives to right ventricular apical pacing (RVAP) in patients with bradycardia requiring permanent cardiac pacing. We aimed to compare the clinical outcomes of LBBAP, HBP, and RVAP in Japanese patients with bradycardia. Methods: A total of 424 patients who underwent successful pacemaker implantation (HBP, n = 53; LBBAP, n = 75; and RVAP, n = 296) were retrospectively enrolled in this study. The primary study endpoint was the cumulative incidence of heart failure hospitalization (HFH) during the follow-up. Results: The success rate for implantation was higher in the LBBAP group than in the HBP group (94.9% and 81.5%, respectively). Capture threshold increase >1V during the follow-up occurred in the HBP and RVAP groups (9.4% and 5.1%, respectively), while it did not in the LBBAP group. The cumulative incidence of HFH was significantly lower in the LBBAP group than the RVAP (adjusted hazard ratio, 0.12 [95% confidence interval: 0.02-0.86]; p = .034); it did not differ between the HBP and RVAP groups (adjusted hazard ratio, 0.48 [95% confidence interval: 0.17-1.34]; p = .16). Advanced age, mean percent right ventricular pacing (per 10% increase), left ventricular ejection fraction <50%, and RVAP were associated with HFH. Conclusions: Compared to RVAP and HBP, LBBAP appeared more feasible and effective in patients with bradycardia requiring permanent cardiac pacing.

3.
BMJ Support Palliat Care ; 13(e3): e1300-e1307, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-37169517

RESUMO

OBJECTIVES: Morphine is effective in alleviating dyspnoea in patients with cancer. We aimed to investigate the effectiveness and safety of morphine administration for refractory dyspnoea in patients with advanced heart failure (HF). METHODS: We conducted a multicentre, prospective, observational study of hospitalised patients with advanced HF in whom morphine was administered for refractory dyspnoea. Morphine effectiveness was evaluated by dyspnoea intensity changes, assessed regularly by both a quantitative subjective scale (Visual Analogue Scale (VAS; graded from 0 to 100 mm)) and an objective scale (Support Team Assessment Schedule-Japanese (STAS-J; graded from 0 to 4 points)). Safety was assessed by vital sign changes and new-onset severe adverse events, including nausea, vomiting, constipation and delirium based on the Common Terminology Criteria for Adverse Events. RESULTS: From 15 Japanese institutions between September 2020 and August 2022, we included 28 hospitalised patients with advanced HF in whom morphine was administered (mean age: 83.8±8.7 years, male: 15 (54%), New York Heart Association class IV: 26 (93%) and mean left ventricular ejection fraction: 38%±19%). Both VAS and STAS-J significantly improved from baseline to day 1 (VAS: 67±26 to 50±31 mm; p=0.02 and STAS-J: 3.3±0.8 to 2.6±1.1 points; p=0.006, respectively), and thereafter the improvements sustained through to day 7. After morphine administration, vital signs including blood pressure, pulse rate and oxygen saturation did not change, and no new-onset severe adverse events occurred through to day 7. CONCLUSIONS: This study suggested acceptable effectiveness and safety for morphine administration in treating refractory dyspnoea in hospitalised patients with advanced HF.


Assuntos
Insuficiência Cardíaca , Neoplasias , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Dispneia/etiologia , Dispneia/induzido quimicamente , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/tratamento farmacológico , Morfina/efeitos adversos , Estudos Prospectivos , Feminino
4.
J Interv Card Electrophysiol ; 67(3): 589-597, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691083

RESUMO

BACKGROUND: Lesion formation during catheter ablation is influenced by the power, contact force (CF), time, and catheter stability. However, the influence of the irrigation effects on lesion formation remains unknown. METHODS: An ex vivo experiment using conductive gel was performed. Using three different catheter designs (TactiFlex ™ SE [TF], IntellaNav MiFi ™ OI [MiFi], QDOT MICRO™ [QDOT]), a cross-sectional analysis of the lesion size and surface lesion type of 10g/40W lesions with a combination of various ablation times was performed in protocol 1. A longitudinal analysis (combination of various powers [30, 40, and 50W] and various ablation times with a 10g setting) was performed to investigate the influence of the auto-regulated irrigation system (QDOT) on lesion formation in protocol 2. RESULTS: The lesion formation with the QDOT catheter tended to create larger ablation lesions, while that with the TF catheter created smaller lesions than the other catheters. The lesion surface characteristics were divided into two patterns: ring (MiFi catheter and QDOT) and crescent (TF) patterns. The auto-regulated irrigation system did not influence the lesion formation, and the relationship between the lesion formation and RF energy exhibited similar changes regardless of the ablation power setting. CONCLUSION: The lesion formation and lesion surface characteristics differed among the different irrigation tip designs. An auto-regulated irrigation system did not affect the lesion creation or surface lesion characteristics. Care should be given to the inter-product differences in the lesion characteristics during RF catheter ablation, partly due to the irrigation flow control and tip design.


Assuntos
Ablação por Cateter , Irrigação Terapêutica , Humanos , Estudos Transversais , Irrigação Terapêutica/métodos , Catéteres , Ablação por Cateter/métodos , Impedância Elétrica , Desenho de Equipamento
5.
J Cardiovasc Electrophysiol ; 34(12): 2461-2471, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37702156

RESUMO

INTRODUCTION: Treatment of recurrent atrial fibrillation (AF) is sometimes challenging due to non-pulmonary vein (PV) foci. Fractionated signal area in the atrial muscle (FAAM) is a valid predictor of the location of non-PV foci. FAAM ablation has the potential to decrease the recurrence rate of atrial tachyarrhythmia in patients with recurrent AF. We compared the clinical impact of FAAM ablation for recurrent AF, using 1 year follow up date. METHODS: A total of 230 consecutive patients with symptomatic recurrent AF who underwent catheter ablation specifically targeting non-PV foci as FAAM-guided ablation (n = 113) and non-FAAM-guided ablation (n = 117) were retrospectively analyzed. FAAM was assigned a parameter (peaks slider, which indicates the number of components of fractionated signals), ranging from 1 to 15, indicating the location of the FAAM (1: largest, 15: smallest). FAAM-guided ablation was performed by ablating FAAM until none inducibility of non-PV foci. On the other hand, non-FAAM-guided ablation was performed via linear ablation, complex fractionated atrial electrogram ablation, superior vena cava isolation, and focal ablation according to the location of the non-PV foci. The RHYTHMIA system was used to perform all the procedures. The primary endpoints were AF recurrence, atrial flutter, and/or atrial tachycardia. RESULTS: After a 1-year follow up, freedom from atrial tachyarrhythmia was achieved in 90.3% and 75.2% of patients in the FAAM and non-FAAM groups, respectively (hazard ratio = 0.438 [95% confidence interval: 0.243-0.788], p = .005). CONCLUSIONS: FAAM ablation showed a promising decrease in the recurrence rate of atrial tachyarrhythmia in patients with recurrent AF during a 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Estudos Retrospectivos , Veia Cava Superior , Resultado do Tratamento , Taquicardia , Músculos/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
6.
J Cardiol Cases ; 28(1): 21-23, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37360828

RESUMO

In young patients with transvenous implantable cardioverter defibrillations (TV-ICDs), the possibility of device infection or lead fracture would be high in their long lifetimes. Furthermore, the risk of lead removal will gradually increase over the years. We reported two cases of subcutaneous ICDs implantation following removal of TV-ICDs. Patient 1, 35-year-old man, underwent TV-ICD implantation 9 years ago for idiopathic ventricular fibrillation, and Patient 2, 46-year-old man, underwent TV-ICD implantation 8 years ago for asymptomatic Brugada syndrome. In both cases, the electrical performance was stable, and there was no incidence of arrythmia or no pacing demand during the follow-up duration. Considering future risk of device infection or lead fracture, and difficulty in future lead removal, TV-ICDs were removed with sufficient informed consent, and then, subcutaneous ICDs (S-ICDs) implantation were performed as an alternative to them. Although indication of the TV-ICD removal should be carefully considered in individual cases, long-term risks leaving it in place should be also considered in the management of young patient. Learning objective: In young patient with TV-ICD, even for a normally functioning non-infected lead, S-ICD implantation following removal of the TV-ICD would represent a strategy associated with less long-term risks than leaving it in place.

7.
J Arrhythm ; 38(5): 730-735, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36237858

RESUMO

Introduction: The long-term performance of leadless pacemaker (LPM) has not been well evaluated. Methods: Between September 2017 and January 2021, 929 consecutive patients who underwent pacemaker implantation were grouped according to the types of pacemakers: LPM (LPM group, n = 368) and conventional pacemaker (PM group, n = 561). Results: The median follow-up duration was 1.7 years (interquartile range 0.8-2.6 years). Hospitalization rate for heart failure in the LPM group was 9.3%, 15.6%, and 21.6% at 1, 2, 3 years, respectively. The LPM group had a significantly higher adjusted heart failure hospitalization risk than the PM group [hazard ratio (HR) 1.70, 95% confidence interval (CI) 1.09-2.64, p = .01]. More patients with symptomatic bradycardia caused by sinus node dysfunction (SND) in the LPM group (n = 150) were admitted to the hospital for heart failure compared to those in the PM group (n = 219) (HR 2.02, 95%CI 1.04-3.90, p = .03), whereas no significant difference was observed between the two groups in the patients with bradycardia caused by atrial fibrillation (LPM group, n = 71; PM group, n = 18) or atrioventricular block (LPM group, n = 147; PM group, n = 324). Conclusions: Patients who received LPM implantation had greater hospitalization risk for heart failure, compared to those who received conventional pacemaker implantation. The increased risk was mainly attributed to patients with SND.

8.
J Arrhythm ; 37(3): 645-652, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34141017

RESUMO

BACKGROUND: The incidence, predictors, and clinical impact of lead break during transvenous lead extraction (TLE) were previously unknown. METHODS: We included consecutive patients who underwent TLE between September 2013 and July 2019 at our institute. Lead break during removal was defined as lead stretching and becoming misshapen, as assessed by fluoroscopy. RESULTS: A total of 246 patients underwent TLE for 501 leads. At a patient level, complete success was achieved in 226 patients (91.9%). At a lead level, 481 leads (96.0%) were completely removed and 101 leads (20.1%) were broken during the procedure. Of 392 identified pacemaker leads, 71 (18.3%) were broken during the TLE procedure. A multivariable analysis confirmed high lead age (odds ratio [OR] 1.12, 95% confidence interval (CI) 1.07-1.17; P < .001), passive leads (OR 2.29 95% CI 1.09-4.80; P = .028), coradial leads (OR 3.45 95% CI 1.72-6.92; P < .001), and insulators made of nonpolyurethane (OR 2.38 95% CI 1.03-5.26; P = .04) as predictors of lead break. Broken leads needed longer procedure times and were associated with a higher rate of cardiac tamponade. CONCLUSIONS: Lead age, coradial bipolar leads, passive leads, and leads without polyurethane insulation were predictors of lead break and could increase the difficulty of lead extraction.

10.
J Cardiovasc Electrophysiol ; 32(2): 224-234, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33270298

RESUMO

BACKGROUND: The role of nonpulmonary vein (PV) triggers ablation in persistent atrial fibrillation (PEAF) was suggested but it is still under debate. OBJECTIVES: We aimed to assess the effectiveness of non-PV trigger-targeted ablation for patients with PEAF. METHODS: Consecutive patients with PEAF undergoing catheter ablation (CA) between January 2015 and April 2017 were enrolled. Isoproterenol plus adenosine challenge was performed to provoke non-PV triggers. Non-PV triggers were defined as the trigger beats inducing AF (non-PV AF triggers) and/or frequent premature contractions (non-PV PACs) from other than PVs. Three groups were defined: Group 1 (n = 186) without non-PV triggers; Group 2 (n = 65) with non-PV triggers that could be completely eliminated with CA; Group 3 (n = 49) with non-PV triggers still inducible after CA. The primary endpoint was freedom from any atrial tachyarrhythmia (ATa) recurrence. RESULTS: A total of 300 patients (230 males, age 64 ± 10) were enrolled. The mean follow-up period was 27 ± 10 months. Freedom from ATa recurrence at 1 and 2 years were significantly lower in Group 3 compared to the other two groups (Group 1; 74.7%, 67.2% vs. Group 2; 75.8%, 68.3% vs. Group 3: 52.1%, 38.6%, p = .0005), irrespective of the type of non-PV triggers (non-PV AF triggers vs. non-PV PACs). On multivariate analysis, unsuccessful elimination of non-PV triggers was an independent predictor for ATa recurrence (hazard ratio = 1.80, 95% confidence interval = 1.07-2.95, p = .026). CONCLUSION: Successful non-PV triggers elimination can improve the ATa recurrence rate in PEAF ablation. ATa recurrence rate is higher, if non-PV AF triggers or even non-PV PACs remain in patients with PEAF.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Ablação por Cateter/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
12.
Circ J ; 81(4): 485-494, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28179592

RESUMO

BACKGROUND: There is discordance regarding the effect of symptom status before aortic valve replacement (AVR) on long-term outcome after AVR in severe aortic stenosis (AS).Methods and Results:The CURRENT AS registry is a multicenter retrospective registry enrolling 3,815 consecutive patients with severe AS. Among 1,196 patients managed with the initial AVR strategy, long-term clinical outcomes were compared between the symptomatic patients (n=905), and asymptomatic patients (n=291). Median follow-up interval was 1337 days with a 91% follow-up rate at 2 years. AVR was performed in 886 patients (98%) in the symptomatic group and in 287 patients (99%) in the asymptomatic group. Symptomatic patients were older and more often had comorbidities than asymptomatic patients with similar echocardiographic AS severity. The cumulative 5-year incidences of all-cause death and heart failure (HF) hospitalization were significantly higher in symptomatic patients than in asymptomatic patients (25.6% vs. 15.4%, P=0.001, and 14.2% vs. 3.8%, P<0.001, respectively). On landmark analysis at 30 days after AVR, the differences in mortality and HF hospitalization between the 2 groups were mainly observed beyond 30 days. CONCLUSIONS: When managed with the initial AVR strategy, the long-term outcomes of symptomatic severe AS were worse than those of asymptomatic severe AS. Early AVR strategy might be recommended in some selected asymptomatic severe AS patients with reasonable operative risk.


Assuntos
Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Avaliação de Sintomas/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Comorbidade , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...