1.
Eur J Heart Fail ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899626

RESUMO

AIMS: Haemodynamic monitoring using implantable pressure sensors reduces the risk of heart failure (HF) hospitalizations. Patient self-management (PSM) of haemodynamics in HF has the potential to personalize treatment, increase adherence, and reduce the risk of worsening HF, while lowering clinicians' burden. METHODS AND RESULTS: The VECTOR-HF I and IIa studies are prospective, single-arm, open-label clinical trials assessing safety, usability and performance of left atrial pressure (LAP)-guided HF management using PSM in New York Heart Association class II and III HF patients. Physician-prescribed LAP thresholds trigger patient self-adjustment of diuretics. Primary endpoints include the ability to perform LAP measurements and transmit data to the healthcare provider (HCP) interface and the patient guidance application, and safety outcomes. This is an interim analysis of 13 patients using the PSM approach. Over 12 months, no procedure- or device-related major adverse cardiovascular or neurological events were observed, and there were no failures to obtain measurements from the sensor and transmit the data to the HCP interface and the patient guidance application. Patient adherence was 91.4%. Using PSM, annualized HF hospitalization rate significantly decreased compared to a similar period prior to PSM utilization (0 admissions vs. 0.69 admissions over 11.84 months, p = 0.004). At 6 months, 6-min walk test distance and the Kansas City Cardiomyopathy Questionnaire overall summary score demonstrated significant improvement. CONCLUSIONS: Interim findings suggest that PSM using a LAP monitoring system is feasible and safe. PSM is associated with high patient adherence, potentially improving HF patients' functional status, quality of life, and limiting HF hospitalizations.

2.
Eur J Heart Fail ; 25(6): 902-911, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37092287

RESUMO

AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Humanos , Cateterismo Cardíaco/métodos , Estudos Prospectivos , Pressão Propulsora Pulmonar
3.
J Card Fail ; 28(6): 963-972, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35041933

RESUMO

OBJECTIVE: Patients with heart failure (HF) are at an increased risk of hospital admissions. The aim of this report is to describe the feasibility, safety and accuracy of a novel wireless left atrial pressure (LAP) monitoring system in patients with HF. METHODS: The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) study is a prospective, multicenter, single-arm, open-label, first-in human clinical trial to assess the safety, performance and usability of the V-LAP system (Vectorious Medical Technologies) in patients with New York Heart Association class III HF. The device was implanted in the interatrial septum via a percutaneous, trans-septal approach guided by fluoroscopy and echocardiography. Primary endpoints included the successful deployment of the implant, the ability to perform initial pressure measurements and safety outcomes. RESULTS: To date, 24 patients have received implants of the LAP-monitoring device. No device-related complications have occurred. LAP was reported accurately, agreeing well with wedge pressure at 3 months (Lin concordance correlation coefficient = 0.850). After 6 months, New York Heart Association class improved in 40% of the patients (95% CI = 16.4%-63.5%), while the 6-minute walk test distance had not changed significantly (313.9 ± 144.9 vs 232.5 ± 129.9 meters; P = 0.076). CONCLUSION: The V-LAP left atrium monitoring system appears to be safe and accurate.


Assuntos
Pressão Atrial , Insuficiência Cardíaca , Cateterismo Cardíaco , Humanos , Estudos Prospectivos , Volume Sistólico