1.
Sensors (Basel) ; 20(21)2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182354

RESUMO

In this work, a regression method is implemented on a low-cost digital temperature sensor to improve the sensor's accuracy; thus, following the EN12830 European standard. This standard defines that the maximum acceptable error regarding temperature monitoring devices should not exceed 1 °C for the refrigeration and freezer areas. The purpose of the proposed method is to improve the accuracy of a low-cost digital temperature sensor by correcting its nonlinear response using simple linear regression (SLR). In the experimental part of this study, the proposed method's outcome (in a custom created dataset containing values taken from a refrigerator) is compared against the values taken from a sensor complying with the EN12830 standard. The experimental results confirmed that the proposed method reduced the mean absolute error (MAE) by 82% for the refrigeration area and 69% for the freezer area-resulting in the accuracy improvement of the low-cost digital temperature sensor. Moreover, it managed to achieve a lower generalization error on the test set when compared to three other machine learning algorithms (SVM, B-ELM, and OS-ELM).