Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Placenta ; 69: 20-25, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30213480

RESUMO

INTRODUCTION: Pregnancy complicated by diabetes mellitus (DM) is a central obstetric problem often complicated by fetal macrosomia and increased risk of intrapartum asphyxia. This risk might be explained by fetoplacental vascular abnormalities. This study aimed to investigate the fetoplacental vascular volume by placental CT angiography in normal pregnancies and in pregnancies complicated by type 1 DM (T1DM), diet controlled gestational DM (GDMd), and insulin treated gestational DM (GDMi). METHODS: Postpartum, barium contrast enhanced placental CT angiography was performed in 27 normal pregnancies and 25 DM pregnancies (8 T1DM, 8 GDMd, and 9 GDMi). The fetoplacental vascular volume/placenta weight (FVV/PW)-ratio and fetoplacental vascular volume/birth weight (FVV/BW)-ratio of each diabetic group were compared to the normal group with multiple regression analysis adjusted for GA. In all pregnancies a standardized histopathological placental examination was performed postpartum. RESULTS: In normal pregnancies, the fetoplacental vascular volume increased with GA (p < 0.001), placental weight (p < 0.001), and birth weight (p < 0.001). In T1DM and GDMi pregnancies, the gestational age adjusted placental weight and the birth weight were increased when compared to normal pregnancies (p < 0.05). The FVV/BW-ratio was significantly reduced in both T1DM and GDMi pregnancies when compared to normal pregnancies (p = 0.003 and p = 0.009, respectively). DISCUSSION: This study demonstrates, that in insulin treated DM pregnancies the fetus as well as the placenta is larger than normal. However, despite a large placenta, a relatively smaller fetoplacental vascular volume supplies the macrosomic fetus. This finding might explain why fetuses from insulin treated DM pregnancies have high vulnerability to intrauterine and intrapartum asphyxia.


Assuntos
Angiografia por Tomografia Computadorizada , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Diabetes Gestacional/diagnóstico por imagem , Macrossomia Fetal/diagnóstico por imagem , Placenta/irrigação sanguínea , Placenta/diagnóstico por imagem , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Gestacional/dietoterapia , Diabetes Gestacional/tratamento farmacológico , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Gravidez , Gravidez em Diabéticas
2.
J Appl Clin Med Phys ; 17(3): 294-303, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167285

RESUMO

In image-guided radiotherapy (IGRT) of prostate cancer, delineation of the clini-cal target volume (CTV) often relies on magnetic resonance (MR) because of its good soft-tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR-CT registration of the prostate has previously been developed using a voxel property-based registration as an alternative to a manual landmark-based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni-Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Marcadores Fiduciais , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Níquel , Posicionamento do Paciente , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Titânio
3.
Med Phys ; 42(4): 1614-24, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832052

RESUMO

PURPOSE: An automatic method for 3D prostate segmentation in magnetic resonance (MR) images is presented for planning image-guided radiotherapy treatment of prostate cancer. METHODS: A spatial prior based on intersubject atlas registration is combined with organ-specific intensity information in a graph cut segmentation framework. The segmentation is tested on 67 axial T2-weighted MR images in a leave-one-out cross validation experiment and compared with both manual reference segmentations and with multiatlas-based segmentations using majority voting atlas fusion. The impact of atlas selection is investigated in both the traditional atlas-based segmentation and the new graph cut method that combines atlas and intensity information in order to improve the segmentation accuracy. Best results were achieved using the method that combines intensity information, shape information, and atlas selection in the graph cut framework. RESULTS: A mean Dice similarity coefficient (DSC) of 0.88 and a mean surface distance (MSD) of 1.45 mm with respect to the manual delineation were achieved. CONCLUSIONS: This approaches the interobserver DSC of 0.90 and interobserver MSD 0f 1.15 mm and is comparable to other studies performing prostate segmentation in MR.


Assuntos
Atlas como Assunto , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Próstata/anatomia & histologia , Humanos , Masculino , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiografia , Planejamento da Radioterapia Assistida por Computador/métodos
4.
Acta Oncol ; 52(7): 1374-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24007443

RESUMO

BACKGROUND: The prostate gland is delineated as the clinical target volume (CTV) in treatment planning of prostate cancer. Therefore, an accurate delineation is a prerequisite for efficient treatment. Accurate automated prostate segmentation methods facilitate the delineation of the CTV without inter-observer variation. The purpose of this study is to present an automated three-dimensional (3D) segmentation of the prostate using an active appearance model. MATERIAL AND METHODS: Axial T2-weighted magnetic resonance (MR) scans were used to build the active appearance model. The model was based on a principal component analysis of shape and texture features with a level-set representation of the prostate shape instead of the selection of landmarks in the traditional active appearance model. To achieve a better fit of the model to the target image, prior knowledge to predict how to correct the model and pose parameters was incorporated. The segmentation was performed as an iterative algorithm to minimize the squared difference between the target and the model image. RESULTS: The model was trained using manual delineations from 30 patients and was validated using leave-one-out cross validation where the automated segmentations were compared with the manual reference delineations. The mean and median dice similarity coefficient was 0.84 and 0.86, respectively. CONCLUSION: This study demonstrated the feasibility for an automated prostate segmentation using an active appearance with results comparable to other studies.


Assuntos
Imageamento por Ressonância Magnética , Modelos Estatísticos , Reconhecimento Automatizado de Padrão , Neoplasias da Próstata/patologia , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Prognóstico , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem
5.
Med Phys ; 40(6): 061907, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23718598

RESUMO

PURPOSE: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. METHODS: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. RESULTS: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. CONCLUSIONS: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.


Assuntos
Imageamento por Ressonância Magnética/estatística & dados numéricos , Níquel , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/instrumentação , Stents , Técnica de Subtração/instrumentação , Titânio , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Marcadores Fiduciais , Humanos , Masculino , Imagem Multimodal/instrumentação , Neoplasias da Próstata/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...