Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
PLoS One ; 16(1): e0245189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33428663

RESUMO

Automated testing of HIV serology on clinical chemistry analysers has become common. High sample throughput, high HIV prevalence and instrument design could all contribute to sample cross-contamination by microscopic droplet carry-over from seropositive samples to seronegative samples resulting in false positive low-reactive results. Following installation of an automated shared platform at our public health laboratory, we noted an increase in low reactive and false positive results. Subsequently, we investigated HIV serology screening test results for a period of 21 months. Of 485 initially low positive or equivocal samples 411 (85%) tested negative when retested using an independently collected sample. As creatinine is commonly requested with HIV screening, we used it as a proxy for concomitant clinical chemistry testing, indicating that a sample had likely been tested on a shared high-throughput instrument. The contamination risk was stratified between samples passing the clinical chemistry module first versus samples bypassing it. The odds ratio for a false positive HIV serology result was 4.1 (95% CI: 1.69-9.97) when creatinine level was determined first, versus not, on the same sample, suggesting contamination on the chemistry analyser. We subsequently issued a notice to obtain dedicated samples for HIV serology and added a suffix to the specimen identifier which restricted testing to a dedicated instrument. Low positive and false positive rates were determined before and after these interventions. Based on measured rates in low positive samples we estimate that before the intervention, of 44 117 HIV screening serology samples, 753 (1.71%) were false positive, declining to 48 of 7 072 samples (0.68%) post-intervention (p<0.01). Our findings showed that automated high throughput shared diagnostic platforms are at risk of generating false-positive HIV test results, due to sample contamination and that measures are required to address this. Restricting HIV serology samples to a dedicated platform resolved this problem.


Assuntos
Sorodiagnóstico da AIDS , Infecções por HIV , HIV-1 , Programas de Rastreamento , Reações Falso-Positivas , Feminino , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Humanos , Masculino , Prevalência
2.
J Virol Methods ; 193(1): 166-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23792685

RESUMO

CMV is a common cause of disease in immunocompromised patients. Because sampling of the diseased organ can be invasive, markers of systemic CMV reactivation such as pp65 and CMV viral load are commonly used to monitor patients at risk of CMV disease. In this retrospective analysis, the performance of these markers was compared in solid organ transplant recipients, patients with haematological malignancies and HIV infection. Both assays were sensitive markers of reactivation, however, the predictive value for disease of a positive result for both was low. Compared to viral load, the pp65 assay was a less sensitive marker of CMV reactivation. It was only positive when the viral load was greater than 3 log (10) copies/ml whole blood and was negative in 10 instances when the viral load was between 3 and 5 logs. In concordantly positive samples, the number of pp65 positive cells varied widely relative to the viral load and the number of positive cells counted could not be used to predict disease likelihood with any certainty. To conclude, CMV viral load provides a more consistent guide to determine likelihood of disease than pp65 count and is a more sensitive marker of CMV reactivation.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Citomegalovirus/diagnóstico , Citomegalovirus/isolamento & purificação , Fosfoproteínas/sangue , Carga Viral , Proteínas da Matriz Viral/sangue , Infecções por Citomegalovirus/virologia , Infecções por HIV/complicações , Neoplasias Hematológicas/complicações , Humanos , Transplante de Órgãos/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Transplante , Ativação Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...