1.
Ultrasound Med Biol ; 50(3): 434-444, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38143187

RESUMO

OBJECTIVE: Post-operative brain injury in neonates may result from disturbed cerebral perfusion, but accurate peri-operative monitoring is lacking. High-frame-rate (HFR) cerebral ultrasound could visualize and quantify flow in all detectable vessels using spectral Doppler; however, automated quantification in small vessels is challenging because of low signal amplitude. We have developed an automatic envelope detection algorithm for HFR pulsed wave spectral Doppler signals, enabling neonatal brain quantitative parameter maps during and after surgery. METHODS: HFR ultrasound data from high-risk neonatal surgeries were recorded with a custom HFR mode (frame rate = 1000 Hz) on a Zonare ZS3 system. A pulsed wave Doppler spectrogram was calculated for each pixel containing blood flow in the image, and spectral peak velocity was tracked using a max-likelihood estimation algorithm of signal and noise regions in the spectrogram, where the most likely cross-over point marks the blood flow velocity. The resulting peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistivity index (RI) were compared with other detection schemes, manual tracking and RIs from regular pulsed wave Doppler measurements in 10 neonates. RESULTS: Envelope detection was successful in both high- and low-quality arterial and venous flow spectrograms. Our technique had the lowest root mean square error for EDV, PSV and RI (0.46 cm/s, 0.53 cm/s and 0.15, respectively) when compared with manual tracking. There was good agreement between the clinical pulsed wave Doppler RI and HFR measurement with a mean difference of 0.07. CONCLUSION: The max-likelihood algorithm is a promising approach to accurate, automated cerebral blood flow monitoring with HFR imaging in neonates.


Assuntos
Hemodinâmica , Ultrassonografia Doppler , Recém-Nascido , Humanos , Ultrassonografia , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/diagnóstico por imagem , Algoritmos
2.
J Clin Anesth ; 92: 111312, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37926064

RESUMO

BACKGROUND: Ultrafast cerebral Doppler ultrasound enables simultaneous quantification and visualization of cerebral blood flow velocity. The aim of this study is to compare the use of conventional and ultrafast spectral Doppler during anesthesia and their potential to show the effect of anesthesiologic procedures on cerebral blood flow velocities, in relation to blood pressure and cerebral oxygenation in infants undergoing inguinal hernia repair. METHODS: A single-center prospective observational cohort study in infants up to six months of age. We evaluated conventional and ultrafast spectral Doppler cerebral ultrasound measurements in terms of number of successful measurements during the induction of anesthesia, after sevoflurane induction, administration of caudal analgesia, a fluid bolus and emergence of anesthesia. Cerebral blood flow velocity was quantified in pial arteries using conventional spectral Doppler and in the cerebral cortex using ultrafast Doppler by peak systolic velocity, end diastolic velocity and resistivity index. RESULTS: Twenty infants were included with useable conventional spectral Doppler images in 72/100 measurements and ultrafast Doppler images in 51/100 measurements. Intraoperatively, the success rates were 53/60 (88.3%) and 41/60 (68.3%), respectively. Cerebral blood flow velocity increased after emergence for both conventional (end diastolic velocity, from 2.01 to 2.75 cm/s, p < 0.001) and ultrafast spectral Doppler (end diastolic velocity, from 0.59 to 0.94 cm/s), whereas cerebral oxygenation showed a reverse pattern with a decrease after the emergence of the infant (85% to 68%, p < 0.001). CONCLUSION: It is possible to quantify cortical blood flow velocity during general anesthesia using conventional and ultrafast spectral Doppler cerebral ultrasound. Cerebral blood flow velocity and blood pressure decreased, while regional cerebral oxygenation increased during general anesthesia. Ultrafast spectral Doppler ultrasound offers novel insights into perfusion within the cerebral cortex, unattainable through conventional spectral ultrasound. Yet, ultrafast Doppler is curtailed by a lower success rate and a more rigorous learning curve compared to conventional method.


Assuntos
Hérnia Inguinal , Ultrassonografia Doppler Transcraniana , Lactente , Humanos , Estudos Prospectivos , Hérnia Inguinal/cirurgia , Ultrassonografia Doppler , Velocidade do Fluxo Sanguíneo , Circulação Cerebrovascular/fisiologia
3.
Front Pediatr ; 9: 656806, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33829005

RESUMO

Background and Aim: Newborns needing major surgical intervention are at risk of brain injury and impaired neurodevelopment later in life. Disturbance of cerebral perfusion might be an underlying factor. This study investigates the feasibility of serial transfontanellar ultrasound measurements of the pial arteries during neonatal surgery, and whether perioperative changes in cerebral perfusion can be observed and related to changes in the perioperative management. Methods: In this prospective, observational feasibility study, neonates with congenital diaphragmatic hernia and esophageal atresia scheduled for surgical treatment within the first 28 days of life were eligible for inclusion. We performed transfontanellar directional power Doppler and pulsed wave Doppler ultrasound during major high-risk non-cardiac neonatal surgery. Pial arteries were of interest for the measurements. Extracted Doppler ultrasound parameters were: peak systolic velocity, end diastolic velocity, the resistivity index and pulsatility index. Results: In 10 out of 14 patients it was possible to perform perioperative measurements; the others failed for logistic and technical reasons. In 6 out of 10 patients, it was feasible to perform serial intraoperative transfontanellar ultrasound measurements with directional power Doppler and pulsed wave Doppler of the same pial artery during neonatal surgery. Median peak systolic velocity was ranging between 5.7 and 7.0 cm s-1 and end diastolic velocity between 1.9 and 3.2 cm s-1. In patients with a vasoactive-inotropic score below 12 the trend of peak systolic velocity and end diastolic velocity corresponded with the mean arterial blood pressure trend. Conclusion: Perioperative transfontanellar ultrasound Doppler measurements of the pial arteries are feasible and provide new longitudinal data about perioperative cortical cerebral blood flow velocity. Trial Registration: https://www.trialregister.nl/trial/6972, identifier: NL6972.

4.
Ultrasound Med Biol ; 43(12): 2751-2757, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28964614

RESUMO

Contrast-enhanced ultrasound (CEUS) has been suggested as a new method to measure cerebral perfusion in patients with acute brain injury. In this systematic review, the tolerability, repeatability, reproducibility and accuracy of different CEUS techniques for the quantification of cerebral perfusion were assessed. We selected studies published between January 1994 and March 2017 using CEUS to measure cerebral perfusion. We included 43 studies (bolus kinetics n = 31, refill kinetics n = 6, depletion kinetics n = 6) with a total of 861 patients. Tolerability was reported in 28 studies describing 12 patients with mild and transient side effects. Repeatability was assessed in 3 studies, reproducibility in 2 studies and accuracy in 19 studies. Repeatability was high for experienced sonographers and significantly lower for less experienced sonographers. Reproducibility of CEUS was not clear. The sensitivity and specificity of CEUS for the detection of cerebral ischemia ranged from 75% to 96% and from 60% to 100%. Limited data on repeatability, reproducibility and accuracy may suggest that this technique could be feasible for use in acute brain injury patients.


Assuntos
Lesões Encefálicas/fisiopatologia , Circulação Cerebrovascular/fisiologia , Meios de Contraste , Aumento da Imagem/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade