Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 17(3): 391-401, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38355267

RESUMO

BACKGROUND: Although permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve replacement (TAVR), hospital variation and change in PPM implantation rates are ill defined. OBJECTIVES: The aim of this study was to determine hospital-level variation and temporal trends in the rate of PPM implantation following TAVR. METHODS: Using the American College of Cardiology/Society of Thoracic Surgeons TVT (Transcatheter Valve Therapy) Registry, temporal changes in variation of in-hospital and 30-day PPM implantation were determined among 184,452 TAVR procedures across 653 sites performed from 2016 to 2020. The variation in PPM implantation adjusted for valve type by annualized TAVR volume was determined, and characteristics of sites below, within, and above the 95% boundary were identified. A series of stepwise multivariable hierarchical models were then fit, and the median OR was used to measure variation in pacemaker rates among sites. RESULTS: From 2016 to 2020, the overall rate of PPM implantation was 11.3%, with wide variation across sites (range: 0%-36.4%); rates trended lower over time. Adjusted for annualized volume, there were 34 sites with PPM implantation rates above the 95th percentile CI and 28 with rates below, with wide variation among the remaining sites. After adjusting for patient-level covariates, there was variation among sites in the probability of PPM implantation (median OR: 1.39; 95% CI: 1.35-1.43, P < 0.001); although some of the variation was explained by the addition of valve type, residual variation in PPM implantation rates persisted in additional models incorporating site-level covariates (annualized volume, region, teaching status, hospital beds, etc). CONCLUSIONS: Although PPM implantation rates have decreased over time, substantial site-level variation remains even after accounting for observed patient characteristics and site-level factors. As there are numerous outlier sites both above and below the 95% confidence limit, dissemination of best practices from high-performing sites to low-performing sites and guideline-based education may be important quality improvement initiatives to reduce rates of this common complication.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de Registros , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...