Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 49(7): 1080-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18552149

RESUMO

UNLABELLED: A triple-detector, multipinhole SPECT system was optimally configured to perform simultaneous (201)Tl (stress)/(99m)Tc (rest) myocardial perfusion imaging (MPI) using a protocol that permitted direct diagnostic comparison of this multipinhole SPECT system with conventional rotational SPECT. METHODS: Both the rotational and the multipinhole SPECT systems used the same model gamma-detectors. The 2 systems were applied in tandem to study 26 patients with documented coronary status. Visual image evaluation of the MPI together with quantitative analysis using circumferential profile curves (CPC) were used for interpretation of stress/rest myocardial flow differences. A dual-peak attenuation compensation (DPAC) technique was applied to the stress (201)Tl multipinhole SPECT images by weighted combination of the images from the upper and lower peaks. RESULTS: Detection of myocardial infarction by location and extent correlated closely, and correlation of differential flow changes between stress and rest indicated similar accuracy in terms of location and extent of myocardial blood flow differences as well. In addition, the application of DPAC clarified the multipinhole stress (201)Tl images through reduced background and increased statistics and also improved the relative superposition of the normalized CPC, especially for the inferior and more basal reconstructed regions. CONCLUSION: The prototype 3-detector multipinhole SPECT system achieved diagnostic results comparable to those for rotational SPECT and required only a single image-acquisition session to generate stress/rest MPI and 16-segment poststress gated studies. This reduction in acquisition time significantly improves productivity without compromising diagnostic accuracy. In addition, DPAC is a useful adjunct to the multipinhole SPECT modality because it improves both the visual clarity of the stress images and the stress/rest quantitative comparability.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Adulto , Idoso , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
J Nucl Med ; 47(4): 595-602, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16595492

RESUMO

UNLABELLED: Myocardial perfusion imaging with SPECT remains critically important for diagnosing, assessing, and evaluating treatment of coronary artery disease. However, conventional rotational SPECT suffers from prolonged study times because of relatively low detection efficiency. We therefore have investigated a multipinhole collimator that could improve the detection efficiency in cardiac SPECT by a factor 5, while providing image quality comparable to standard rotational SPECT techniques using parallel-hole collimation. METHODS: We have measured the spatial resolution and efficiency of a 9-pinhole and a parallel-hole collimator mounted to a standard nuclear medicine gamma-camera as a function of distance from the collimator with a point source array. The efficiency was derived by integrating the detected counts, and the spatial resolution was determined from the full width at half maximum of the detected point spread function. In addition, we generated and reconstructed projection data of a 9-pinhole collimator from a digital heart phantom with a basal lesion. We simulated 3 scenarios: single view from left anterior, 2 views from left anterior and left lateral; and 4 views that include the 2 previous views and left lateral and anterior views. RESULTS: We found that the spatial resolution of the 9-pinhole collimator with 8-mm diameter pinholes was 30% poorer than that for the parallel-hole collimator, whereas the detection efficiency was increased by >10-fold. This predicts that a 9-pinhole collimator having the same spatial resolution as a parallel-hole collimator will have 5 times greater efficiency. Reconstructed data from 1 angular view of the 9-pinhole collimator showed the expected loss of spatial resolution in the longitudinal direction with reduced resolution of the basal lesion. In addition, the tomograms showed distortions in the apical region. In contrast, the reconstructed data from 2 and 4 views of the 9-pinhole collimator demonstrated good lesion definition and also produced images describing the shape and size of the heart more accurately. CONCLUSION: Our results indicate that myocardial multipinhole tomography with 2 or more views offers an image quality and spatial resolution comparable with current rotational SPECT techniques, but with the advantage of a 5-fold increase in efficiency.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Câmaras gama , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...