Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Sci ; 4(3): 100456, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38317867

RESUMO

Objective: Treatment decisions in neovascular age-related macular degeneration (nAMD) are mainly based on subjective evaluation of OCT. The purpose of this cross-sectional study was to provide a comparison of qualitative and quantitative differences between OCT devices in a systematic manner. Design: Prospective, cross-sectional study. Subjects: One hundred sixty OCT volumes, 40 eyes of 40 patients with nAMD. Methods: Patients from clinical practice were imaged with 4 different OCT devices during one visit: (1) Spectralis Heidelberg; (2) Cirrus; (3) Topcon Maestro2; and (4) Topcon Triton. Intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) were manually annotated in all cubes by trained human experts to establish fluid measurements based on expert-reader annotations. Intraretinal fluid, SRF, and PED volume were quantified in nanoliters (nL). Bland-Altman plots were created to analyze the agreement of measurements in the central 1 and 6 mm. The Friedman test was performed to test for significant differences in the central 1, 3, and 6 mm. Main Outcome Measures: Intraretinal fluid, SRF, and PED volume. Results: In the central 6 mm, there was a trend toward higher IRF and PED volumes in Spectralis images compared with the other devices and no differences in SRF volume. In the central 1 mm, the standard deviation of the differences ranged from ± 3 nL to ± 6 nL for IRF, from ± 3 nL to ± 4 nL for SRF, and from ± 7 nL to ± 10 nL for PED in all pairwise comparisons. Manually annotated IRF and SRF volumes showed no significant differences in the central 1 mm. Conclusions: Fluid volume quantification achieved excellent reliability in all 3 retinal compartments on images obtained from 4 OCT devices, particularly for clinically relevant IRF and SRF values. Although fluid volume quantification is reliable in all 4 OCT devices, switching OCT devices might lead to deviating fluid volume measurements with higher agreement in the central 1 mm compared with the central 6 mm, with highest agreement for SRF volume in the central 1 mm. Understanding device-dependent differences is essential for expanding the interpretation and implementation of pixel-wise fluid volume measurements in clinical practice and in clinical trials. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Eye Vis (Lond) ; 10(1): 29, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37291668

RESUMO

PURPOSE: To evaluate the refractive prediction error of common intraocular lens (IOL) power calculation formulae in patients who underwent intrascleral IOL fixation using two different techniques. METHODS: This is a prospective, randomized, longitudinal, single-site, single-surgeon study. Patients who underwent intrascleral IOL implantation using the Yamane or the Carlevale technique were followed up for a period of six months postoperatively. Refraction was measured using the best-corrected visual acuity at 4 m (EDTRS chart). Lens decentration, tilt and effective lens position (ELP) were assessed using an anterior segment optical coherence tomography (AS-OCT). The prediction error (PE) and the absolute error (AE) were evaluated for the SRK/T, Hollayday1 and Hoffer Q formula. Subsequently, correlations between the PE and axial length, keratometry, white to white and ELP were assessed. RESULTS: In total, 53 eyes of 53 patients were included in the study. Twenty-four eyes of 24 patients were in the Yamane group (YG) and 29 eyes of 29 patients were in the Carlevale group (CG). In the YG, the Holladay 1 and Hoffer Q formulae resulted in a hyperopic PE (0.02 ± 0.56 D, and 0.13 ± 0.64 D, respectively) while in the SRK/T formula the PE was slightly myopic (- 0.16 ± 0.56 D). In the CG, SRK/T and Holladay 1 formulae led to a myopic PE (- 0.1 ± 0.80 D and - 0.04 ± 0.74 D, respectively), Hoffer Q to a hyperopic PE (0.04 ± 0.75 D). There was no difference between the PE of the same formulae across both groups (P > 0.05). In both groups the AE differed significantly from zero in each evaluated formula. The AE error was within ± 0.50 D in 45%-71% and was within ± 1.00 D in 72%-92% of eyes depending on the formula and surgical method used. No significant differences were found between formulae within and across groups (P > 0.05). Intraocular lens tilt was lower in the CG (6.45 ± 2.03°) compared to the YG (7.67 ± 3.70°) (P < 0.001). Lens decentration was higher in the YG (0.57 ± 0.37 mm) than in the CG (0.38 ± 0.21 mm), though the difference was not statistically significant (P = 0.9996). CONCLUSIONS: Refractive predictability was similar in both groups. IOL tilt was better in the CG, however this did not influence the refractive predictability. Though not significant, Holladay 1 formula seemed to be more probable than the SRK/T and Hoffer Q formulae. However, significant outliers were observed in all three different formulae and therefore remain a challenging task in secondary fixated IOLs.

3.
Opt Express ; 28(24): 36723-36739, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379760

RESUMO

An adaptive optics optical coherence tomography (AO-OCT) system is used to assess sixty healthy eyes of thirty subjects (age 22 to 75) to evaluate how the outer retinal layers, foveal eccentricity and age effect the mean cone density. The cone mosaics of different retinal planes (the cone inner segment outer segment junction (IS/OS), the cone outer segment combined with the IS/OS (ISOS+), the cone outer segment tips (COST), and the full en-face plane (FEF)) at four main meridians (superior, nasal, inferior, temporal) and para- and perifoveal eccentricities (ecc 2.5° and 6.5°) were analyzed quantitatively. The mean overall cone density was 19,892/mm2 at ecc 2.5° and 13,323/mm2 at ecc 6.5°. A significant impact on cone density was found for eccentricity (up to 6,700/mm2 between ecc 2.5° and 6.5°), meridian (up to 3,700/mm2 between nasal and superior meridian) and layer (up to 1,400/mm2 between FEF and IS/OS). Age showed only a weak negative effect. These factors as well as inter-individual variability have to be taken into account when comparing cone density measurements between healthy and pathologically changed eyes, as their combined effect on density can easily exceed several thousand cones per mm2 even in parafoveal regions.


Assuntos
Envelhecimento/fisiologia , Fóvea Central/diagnóstico por imagem , Imageamento Tridimensional/métodos , Células Fotorreceptoras Retinianas Cones/citologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Contagem de Células , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Estudos Prospectivos , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...