Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ocul Surf ; 14(1): 64-73, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26505667

RESUMO

PURPOSE: To compare the temperatures of the ocular surface, eyelid, and periorbital skin in normal eyes with Sjögren's syndrome (SS) eyes, evaporative dry eyes (EDE), and aqueous deficient dry eyes (ADDE). METHODS: 10 eyes were analyzed in each age-matched group (normal, SS, EDE, and ADDE). A noninvasive infrared thermal camera captured two-dimensional images in three regions of interest (ROI) in each of three areas: the ocular surface, the upper eyelid, and the periorbital skin within a controlled environmental chamber. Mean temperatures in each ROI were calculated from the videos. Ocular surface time-segmented cooling rates were calculated over a 5-s blink interval. RESULTS: Relative to normal eyes, dry eyes had lower initial central OSTs (SS -0.71°C, EDE -0.55°C, ADDE -0.95°C, KW P<.0001) and lower central upper lid temperatures (SS -0.24°C, ADDE -0.51°C, and EDE -0.54°C, KW P<.0001). ADDE eyes had the lowest initial central OST (P<.0001), while EDE eyes had the lowest central lid temperature and lower periorbital temperatures (P<.0001). Over the 5-s interblink interval, the greatest rate of temperature loss occurred following eyelid opening, but varied by group (normals -0.52, SS -0.73, EDE -0.63, and ADDE -0.75°C/s). The ADDE group also had the most substantial heat loss over the 5-s interblink interval (-0.97°C). CONCLUSIONS: Differences in OST may be related to thermal differences in lids and periorbita along with an altered tear film. Thermography of the ocular surface, lids, and surrounding tissues may help to differentiate between different etiologies of dry eye.


Assuntos
Piscadela/fisiologia , Temperatura Corporal/fisiologia , Síndromes do Olho Seco/fisiopatologia , Pálpebras/fisiopatologia , Síndrome de Sjogren/fisiopatologia , Lágrimas/química , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Estudos Retrospectivos , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/metabolismo , Termografia
2.
Exp Eye Res ; 132: 231-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25633347

RESUMO

In this study, we explore the usage of ocular surface temperature (OST) decay patterns to distinguished between dry eye patients with aqueous deficient dry eye (ADDE) and meibomian gland dysfunction (MGD). The OST profiles of 20 dry eye subjects were measured by a long-wave infrared thermal camera in a standardized environment (24 °C, and relative humidity (RH) 40%). The subjects were instructed to blink every 5 s after 20 âˆ¼ 25 min acclimation. Exponential decay curves were fit to the average temperature within a region of the central cornea. We find the MGD subjects have both a higher initial temperature (p < 0.022) and a higher asymptotic temperature (p < 0.007) than the ADDE subjects. We hypothesize the temperature difference among the subpopulations is due to tear volume and heat transfer mechanisms. To study the validity of our claim, we develop a mathematical model, referred to as the thermal impulse perturbation (TIP) model. We conclude that long-wave-infrared thermal imaging is a plausible tool in assisting with the classification of dry eye patient.


Assuntos
Temperatura Corporal/fisiologia , Técnicas de Diagnóstico Oftalmológico , Síndromes do Olho Seco/diagnóstico , Adulto , Idoso , Síndromes do Olho Seco/fisiopatologia , Doenças Palpebrais/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fotografação/métodos
3.
J Biomed Opt ; 17(11): 116010, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23117805

RESUMO

A custom-developed ultrahigh resolution optical coherence tomography with an axial resolution of 1.1 µm in corneal tissue was used to characterize thickness and light scatter of the epithelium and Bowman's layer in keratoconic (KC) cornea noninvasively. A 4-mm wide vertical corneal section around the apex in nine KC and eight normal eyes was imaged in vivo. The epithelium and Bowman's layer were visualized and their thickness profiles were quantified. Scatter was quantified based on the sensitivity normalized mean signal intensity distribution. Average mean thickness of the epithelium and Bowman's layer in KC eyes was significantly smaller (p<0.05) than the normal eyes. The epithelium thickness variation across a central 3-mm cornea was significantly larger in KC eyes than in normal eyes. The scatter in KC eyes was significantly increased only for Bowman's layer. The changes observed in this study could improve our understanding of the underlying disease mechanism of KC and can provide new indications for early disease diagnosis.


Assuntos
Lâmina Limitante Anterior/patologia , Técnicas de Diagnóstico Oftalmológico , Epitélio Corneano/patologia , Ceratocone/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Estudos de Casos e Controles , Técnicas de Diagnóstico Oftalmológico/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Luz , Pessoa de Meia-Idade , Fenômenos Ópticos , Espalhamento de Radiação , Tomografia de Coerência Óptica/estatística & dados numéricos , Adulto Jovem
4.
J Ophthalmol ; 2012: 983182, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22570766

RESUMO

Purpose. To compare the effect of airflow exposure on the tear meniscus and blink frequency in normal and evaporative dry eye subjects. Methods. In 9 normal subjects and 9 short tear breakup time (SBUT) dry eye subjects, lower tear meniscus height (TMH) and area (TMA) and blink frequency were measured with anterior segment optical coherence tomography (OCT) before and after 5 minutes of airflow exposure (1.5 ± 0.5 m/s). Results. In SBUT dry eyes, both TMH and TMA decreased significantly (P = 0.027, P = 0.027) with a significant increase of blink frequency after airflow exposure, while significant increase in TMA was found in normal eyes. Conclusion. Measurement of the tear meniscus with anterior segment OCT seems to be useful as a noninvasive and objective method for evaluating the effect of airflow on tear film.

5.
Ocul Surf ; 10(1): 43-50, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22330058

RESUMO

The clinical tests used to assess tear film and diagnose dry eye are invasive and produce results that are different from natural tear characteristics. There is a need to objectively and noninvasively assess tear parameters under controlled environmental circumstances to refine dry eye diagnosis and therapy. We have developed multimodal tear imaging systems integrated in a chamber in which individual environmental factors can be precisely varied to investigate their impacts on tear parameters. With the custom-built high-resolution wavefront sensor combined with placido disc, it is possible to objectively detect two-dimensional tear breakups in real time and evaluate its impact on visual quality. Micrometer ultra-high resolution optical coherence tomography (OCT) enables us to quantify thickness and volume of the tear over the cornea and tear menisci. The ocular surface imaging ellipsometer uses polarized illumination from which both the lipid refractive index and thickness can be measured at a very high resolution. Using an enhanced thermal camera, we measure the ocular surface temperature noninvasively, which makes it possible to study spatial and temporal changes in tear evaporation. The multimodal deployment of these four components in the controlled chamber will assist in better differentiating the various clinical dry eye entities and will lead to the development of specific dry eye treatments.


Assuntos
Síndromes do Olho Seco/diagnóstico , Lágrimas/fisiologia , Síndromes do Olho Seco/fisiopatologia , Humanos
6.
Cornea ; 31(2): 108-14, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22138585

RESUMO

PURPOSE: To assess the ability of a noninvasive, objective, multimodal system to compare the efficacy and optical quality of 4 different groups of 5 over-the-counter tear drops. METHODS: Wavefront sensing and optical coherence tomography (OCT) were used to objectively assess visual quality and tear volume, respectively, after the over-the-counter tear drops [2 polyethylene glycol (PEG)-400, 1 carboxymethyl cellulose (CMC), 1 polyvinyl alcohol/PEG-400 (PVA), and 1 glycerine/polysorbate-80] were administered to 23 patients with aqueous-deficient dry eye in a randomized, controlled, double-masked trial. Measurements at each of the 5 visits were taken from both eyes at baseline and 5, 20, and 40 minutes after drop instillation. RESULTS: At 5 minutes after drop instillation, the 2 PEG drops showed significant worsening of visual quality (-128.87%, P = 0.001) compared with CMC, PVA, and glycerine drops. Tear volume was elevated significantly with PEG and CMC drops at 5 minutes (+33.2%, P = 0.002; +29.9%, P < 0.001) compared with the other groups. Subjects with a Schirmer score of less than 5 mm at 5 minutes showed improvement in visual quality with PEG drops, whereas those with a fluorescein staining score of 1 to 2 showed improvement with both PEG and CMC drops. A trend toward decreasing visual quality with increasing tear meniscus was noted. CONCLUSIONS: Noninvasive multimodal imaging has the potential to evaluate tear dynamics and the efficacy of artificial tears objectively. Certain artificial tear components and the temporary increase in tear volume after instillation of artificial tears may contribute to transient reduction of visual quality.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Medicamentos sem Prescrição/farmacologia , Soluções Oftálmicas/farmacologia , Lágrimas/efeitos dos fármacos , Adulto , Carboximetilcelulose Sódica/farmacologia , Topografia da Córnea , Método Duplo-Cego , Combinação de Medicamentos , Síndromes do Olho Seco/metabolismo , Síndromes do Olho Seco/patologia , Feminino , Glicerol/farmacologia , Humanos , Masculino , Polietilenoglicóis/farmacologia , Polissorbatos/farmacologia , Álcool de Polivinil/farmacologia , Lágrimas/metabolismo , Tomografia de Coerência Óptica , Acuidade Visual/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...