1.
Heart Vessels ; 34(12): 1925-1935, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31203393

RESUMO

Drug-coated balloon angioplasty (DCBA) has been recognized for its utility in preventing in-stent re-restenosis (ISR); however, imaging of the neointima immediately after treatment and during follow-up has only been described in a few case reports. This study aimed to determine the efficacy and mechanism of the DCBA using imaging studies both immediately after the DCBA and during the follow-up period. We enrolled 15 consecutive patients who underwent DCBA for in-stent restenosis (ISR). The in-stent neointimal volume was evaluated using optical coherence tomography (OCT), and the in-stent yellow grade was assessed using coronary angioscopy (CAS) immediately after DCBA and during the median follow-up period of 9 (8-15) months. The neointimal volume was significantly reduced from 77.1 ± 36.2 mm3 at baseline to 60.2 ± 23.9 mm3 immediately after DCBA (p = 0.0012 vs. baseline) and to 46.7 ± 21.9 mm3 during the follow-up (p = 0.0002 vs. post DCBA). The yellow grade of the residual plaques at the ISR lesion, which indicated plaque vulnerability, was significantly decreased in the follow-up CAG (from baseline: 1.79 ± 1.03, during the follow-up: 0.76 ± 0.82; p < 0.0001). These data suggest that DCBA may inhibit neointimal formation and provide angioscopic intimal stabilization for ISR lesions.


Assuntos
Angioplastia Coronária com Balão/métodos , Angioscopia/métodos , Reestenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico , Tomografia de Coerência Óptica/métodos , Idoso , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Reestenose Coronária/cirurgia , Vasos Coronários/cirurgia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Neointima/patologia , Reoperação , Estudos Retrospectivos
2.
Open Med (Wars) ; 11(1): 155-157, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28352785

RESUMO

Saphenous vein graft aneurysm (SVGA) is one of the chronic complications after coronary aorta bypass grafting (CABG) and may be caused by atherosclerosis-like phenomena of the vein graft, weakness around the vein valve, rupturing of the suture of the graft anastomosis, or perioperative graft injury. We describe a case of a large, growing saphenous vein graft aneurysm that was followed serially by chest radiography and computed tomography. Eighteen years after CABG, an SVGA (23 × 24 mm) was incidentally detected. The patient was asymptomatic and was followed conservatively. Four years later, coronary computed tomographic angiography showed that the giant aneurysm had grown to 52.1 by 63.8 mm and revealed a second, smaller aneurysm. Finally, the SVG was ultimately resected without bypass via off-pump surgery. Therefore, this case suggested that aggressive treatment that includes surgical intervention should be considered before the aneurysm becomes larger, even if it is asymptomatic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...