Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 28(4): 542-548, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33855877

RESUMO

OBJECTIVE: The aim of this study was to provide early-term evaluation, safety, and efficacy of the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure. MATERIALS AND METHODS: All patients who underwent CAS with CGuard carotid stent system from January 2018 to September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success and perioperative neurological events (0-48 hours). Secondary endpoint was the rate of neurologic, cardiac events, and death (major adverse event or MAE) at 30 days. Patency of CGuard, peak systolic velocity (PSV), and end diastolic velocity (EDV) were evaluated at 30 days with duplex ultrasound. RESULTS: A total of 103 patients underwent CAS procedure. Forty patients were symptomatic, and 63 patients were asymptomatic with stenosis greater than 70%. Technical success was 100%. Local anesthesia was applied in 94 patients (93%). Embolic protection devices were used in 6 patients (5.8%). Access site complications were 1.9%. Mean internal carotid artery stenosis diameter reduced from 79.47% to 14.68%. Two patients had transient ischemic attack (1.9%) and 1 patient experienced a cerebral hyperperfusion syndrome (CHS) perioperatively. External carotid artery (ECA) occlusion occurred in 1.9%. Four patients experienced jaw claudication (3.8%) postoperatively. Mean time of operation was 41 minutes. Mean duration of hospitalization was 3.1 days. The 30-day rate of MAE was 0%. CGuard patency was 100%, mean internal carotid PSV was reduced from 251.57 to 77.29 cm/s, and mean internal carotid EDV was reduced from 154.62 to 24.63 cm/s at 30 days. CONCLUSION: Our study shows that CGuard stent with EPS is an effective and safe device for treatment of carotid artery stenosis with acceptable low perioperative neurologic events, even with low embolic protection device usage. Larger multicenter and randomized studies are necessary to confirm its long-term efficacy.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Artérias Carótidas , Artéria Carótida Interna , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Humanos , Israel , Estudos Prospectivos , Stents , Resultado do Tratamento
2.
Vasc Endovascular Surg ; 54(4): 375-377, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32270759

RESUMO

Aberrant right subclavian artery (ARSA) with associated Kommerell diverticulum (KD) is a rare congenital aortic arch anomaly. Patients with KD have a high risk of rupture, dissection, compression of adjacent structures, as well as distal embolization symptoms. Several treatment options have been proposed (surgical, hybrid, endovascular), however, a consensus regarding optimal surgical management has not been established yet. We present a successful single-stage hybrid repair of distal aortic arch dissection aneurysm with dissecting KD and ARSA with debranching of innominate and left common carotid artery, bilateral carotid-subclavian bypass, and stent grafting.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Anormalidades Cardiovasculares/cirurgia , Divertículo/cirurgia , Procedimentos Endovasculares , Artéria Subclávia/anormalidades , Dissecção Aórtica/diagnóstico por imagem , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Anormalidades Cardiovasculares/diagnóstico por imagem , Divertículo/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Resultado do Tratamento
3.
Plant Mol Biol ; 52(5): 981-97, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-14558659

RESUMO

In order to understand some aspects of the circadian clock function in Phaseolus vulgaris, we analyzed the temporal transcript profile of Lhcb genes, typical clock reporters in plants, and that of PvLHY, an orthologue of Arabidopsis thaliana LHY which is a putative transcription factor of Lhcb genes. Under different light regimes, Lhcb and PvLHY exhibit a clear circadian pattern of expression. Moreover, the rhythm of Lhcb genes appears to be tightly coupled to that of PvLHY with the latter having a slightly earlier phase. This supports the idea that the oscillating capacity of PvLHY may be one of the causes of the rhythmic expression of Lhcb genes in bean. In addition to their circadian regulation, Lhcb and PvLHY are induced by light with similar and relatively slow induction kinetics. Moreover, this light induction is gated by the circadian oscillator: minimal responses occur at times around peaks of the pre-existing rhythm, while maximal ones occur at troughs of the pre-existing rhythm. This pattern of gating is opposite to that observed in Arabidopsis. The failure to block the light induction pathways at pre-existing troughs appears to have a detrimental effect to the subsequent circadian rhythmicity. Briefly, the overall regulation of PvLHY and Lhcb genes by light and the circadian clock reveals different strategies between Phaseolus and Arabidopsis in the adaptation to photoperiodic conditions.


Assuntos
Ritmo Circadiano/fisiologia , Proteínas de Ligação a DNA/genética , Phaseolus/genética , Complexo de Proteínas do Centro de Reação Fotossintética/genética , Fatores de Transcrição/genética , Sequência de Aminoácidos , Sequência de Bases , Clonagem Molecular , DNA Complementar/química , DNA Complementar/genética , DNA Complementar/isolamento & purificação , Regulação da Expressão Gênica de Plantas/efeitos da radiação , Luz , Dados de Sequência Molecular , Phaseolus/efeitos da radiação , Fotoperíodo , Alinhamento de Sequência , Análise de Sequência de DNA , Homologia de Sequência de Aminoácidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...