Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 11985, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491550

RESUMO

All types of cranioplasty techniques restore the morphology of the skull and affect patient aesthetics. Safe and easy techniques are required to enhance patients' recovery and the rehabilitation process. We propose a new method of cranioplasty. The 3-dimensional (3D) reconstruction of a thin-layer computed tomography (CT) scan of the skull was used to reflect the intact side onto the defect and subtract the overlapping points from one another. In this way, a 3D model of the planned implant can be built in the required shape and size. The precise fit of the implant can be checked by printing the defective part of the skull in case it can be modified. A sterilisable silicone mould based on the finalized model was created afterwards. Polymethyl methacrylate implants were prepared directly in an aseptic environment in the operating room during surgery. Between 2005 and 2020, we performed 54 cranioplasties on 52 patients whose craniotomies were performed previously for indications of traumatic brain injury, stroke or tumour surgeries. No technical problems were noted during the operations. In 2 cases, septic complications that occurred were not connected to the technique itself, and the implants were removed and later replaced. Our proposed technique based on 3D-printed individual silicone moulds is a reliable, safe, easily reproducible and low-cost method to repair different skull defects.


Assuntos
Procedimentos de Cirurgia Plástica , Polimetil Metacrilato , Humanos , Silicones , Crânio/cirurgia , Próteses e Implantes , Impressão Tridimensional
2.
Eur Spine J ; 27(Suppl 3): 483-488, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29470714

RESUMO

PURPOSE: This article presents a surgical solution of a lumbar disc hernia of a pregnant woman focusing on the use of right lateral positioning, spinal anesthesia which has not previously been utilized in third trimester and discusses positioning options, and possible anesthesia methods with the surgical procedure options. METHODS: Case report. RESULTS: A left-sided L5/S1 lumbar disc hernia (verified by magnetic resonance imaging) of a 35-year-old, 32-week-pregnant woman with a deteriorating neurological status leading to cauda syndrome was treated successfully by microdiscectomy in right lateral position applying spinal anesthesia. CONCLUSIONS: So far examples are given for almost every possible patient position in the third trimester except the right lateral one. All the previously presented positionings (prone, left lateral) were equally effective regarding the outcome with none being better than another. For left-sided lumbar pathologies performed in the third trimester the right lateral position might be an alternative option for easier access. Based on the literature an epidural and general anesthesia can be applied successfully in the third trimester. Spinal anesthesia might be another anesthesia consideration.


Assuntos
Raquianestesia/métodos , Síndrome da Cauda Equina/cirurgia , Discotomia/métodos , Deslocamento do Disco Intervertebral/cirurgia , Posicionamento do Paciente/métodos , Adulto , Síndrome da Cauda Equina/etiologia , Feminino , Humanos , Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/complicações , Vértebras Lombares/cirurgia , Imageamento por Ressonância Magnética , Gravidez , Terceiro Trimestre da Gravidez
3.
Trauma Case Rep ; 12: 48-53, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29644285

RESUMO

One blunt abdominal aortic disruption (BAAD) and one blunt thoracic aortic injury (BTAI) case are presented. Both aortic injuries were combined with spinal fractures. In the BAAD case the aortic pseudoaneurysm manifested just above the lumbar fracture while in the BTAI case the aortic injury appeared several vertebras below the thoracal fracture site, suggesting different mechanisms in the aortic wall damage. In both cases the aortic wall first was sealed, successfully, by endovascularly-placed stents, meaning the risks of open aortic reconstructive surgery could be avoided. The adjacent crucial vessel's preservation, despite the stent covering the left subclavian artery and the left common carotid artery in one of the cases was verified by post-operative computed tomography angiography (CTA) examination. In second stage those spinal fractures which were deemed unstable were stabilized by the fixateur interne (a transpedicular screw-rod system). With this treatment sequence we wanted to avoid the unnecessary risk of a possible rupture of the unsealed aortic wall during positioning for the spinal procedure and during the spinal surgery. Both patients recovered from their aortic and spinal injuries.

4.
Trauma Case Rep ; 12: 66-71, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29644289

RESUMO

This surgical technical case report presents initial clinical experience and preliminary results with a less invasive surgical solution for selected hangman's fracture. A well-known stabilization technique (i.e. direct transpedicular osteosynthesis) was applied through a minimally invasive small incision transmuscular posterior approach guided by a standard C-arm fluoroscopy. This mini-open approach to C2 vertebra allows similar dissection, visualization of the bony landmarks, visual control of the transpedicular screw path drilling, tapping and screw insertion to the standard posterior cervical spine approach. At the same time it has the benefits of less invasive procedures.

5.
Eur Spine J ; 26(Suppl 1): 24-30, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27230784

RESUMO

PURPOSE: To detail the management, complications and results of a crossbow arrow injury, where the broadhead went through the mouth, tongue, soft palate, C2 vertebra, spinal canal, dural sack, exiting the neck posteriorly and the arrow shaft lodged in the spine causing mild spinal cord injury. METHODS: Case presentation. RESULTS: A penetrating axial cervical spine crossbow injury was treated successfully in spite of the following interdisciplinary complications: meningitis, cerebrospinal fluid leakage, re-bleeding, and cardiac arrest. The shaft was removed from the neck, and C1-3 dorsal stabilization was performed. Controlled Computed Tomography (CT) showed adequate implant position. After 4 months the patient's fine motor skills improved, and he became able to button his shirt on his own, and to eat and drink without any help. Additionally, he was able to walk without any support. At the time of control at the outpatient clinic his behavior was adequate: he cooperated with the examining doctor and answered with short sentences although his psychomotor skills were slightly slower. CONCLUSIONS: Although bow and crossbow spine injuries are rare nowadays they still occur. The removal of a penetrating missile resulting in such a spinal injury required a unique solution. General considerations, such as securing the airway, leaving the penetrating arrow in the neck and immobilizing both the arrow and neck for transport, thorough diagnostic imaging, preventing cerebrospinal fluid leakage, administering prophylactic antibiotics with broad coverage and stabilizing the spine if required, are advised.


Assuntos
Vértebras Cervicais/lesões , Doenças do Sistema Nervoso/etiologia , Canal Medular/lesões , Traumatismos da Coluna Vertebral , Ferimentos Penetrantes , Humanos , Masculino , Pessoa de Meia-Idade , Lesões do Pescoço/etiologia , Lesões do Pescoço/cirurgia , Traumatismos da Coluna Vertebral/complicações , Traumatismos da Coluna Vertebral/cirurgia , Resultado do Tratamento , Ferimentos Penetrantes/complicações , Ferimentos Penetrantes/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...