Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Res Protoc ; 13: e55452, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713508

RESUMO

BACKGROUND: Physical capacity and physical activity are important aspects of physical functioning and quality of life in people with a chronic disease such as Parkinson disease (PD) or chronic obstructive pulmonary disease (COPD). Both physical capacity and physical activity are currently measured in the clinic using standardized questionnaires and tests, such as the 6-minute walk test (6MWT) and the Timed Up and Go test (TUG). However, relying only on in-clinic tests is suboptimal since they offer limited information on how a person functions in daily life and how functioning fluctuates throughout the day. Wearable sensor technology may offer a solution that enables us to better understand true physical functioning in daily life. OBJECTIVE: We aim to study whether device-assisted versions of 6MWT and TUG, such that the tests can be performed independently at home using a smartwatch, is a valid and reliable way to measure the performance compared to a supervised, in-clinic test. METHODS: This is a decentralized, prospective, observational study including 100 people with PD and 100 with COPD. The inclusion criteria are broad: age ≥18 years, able to walk independently, and no co-occurrence of PD and COPD. Participants are followed for 15 weeks with 4 in-clinic visits, once every 5 weeks. Outcomes include several walking tests, cognitive tests, and disease-specific questionnaires accompanied by data collection using wearable devices (the Verily Study Watch and Modus StepWatch). Additionally, during the last 10 weeks of this study, participants will follow an aerobic exercise training program aiming to increase physical capacity, creating the opportunity to study the responsiveness of the remote 6MWT. RESULTS: In total, 89 people with PD and 65 people with COPD were included in this study. Data analysis will start in April 2024. CONCLUSIONS: The results of this study will provide information on the measurement properties of the device-assisted 6MWT and TUG in the clinic and at home. When reliable and valid, this can contribute to a better understanding of a person's physical capacity in real life, which makes it possible to personalize treatment options. TRIAL REGISTRATION: ClinicalTrials.gov NCT05756075; https://clinicaltrials.gov/study/NCT05756075. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/55452.


Assuntos
Doença de Parkinson , Doença Pulmonar Obstrutiva Crônica , Dispositivos Eletrônicos Vestíveis , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/psicologia , Doença de Parkinson/fisiopatologia , Doença de Parkinson/diagnóstico , Estudos Prospectivos , Masculino , Idoso , Feminino , Teste de Caminhada/métodos , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Desempenho Físico Funcional , Qualidade de Vida
2.
J Card Fail ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582256

RESUMO

BACKGROUND: Data collected via wearables may complement in-clinic assessments to monitor subclinical heart failure (HF). OBJECTIVES: Evaluate the association of sensor-based digital walking measures with HF stage and characterize their correlation with in-clinic measures of physical performance, cardiac function and participant reported outcomes (PROs) in individuals with early HF. METHODS: The analyzable cohort included participants from the Project Baseline Health Study (PBHS) with HF stage 0, A, or B, or adaptive remodeling phenotype (without risk factors but with mild echocardiographic change, termed RF-/ECHO+) (based on available first-visit in-clinic test and echocardiogram results) and with sufficient sensor data. We computed daily values per participant for 18 digital walking measures, comparing HF subgroups vs stage 0 using multinomial logistic regression and characterizing associations with in-clinic measures and PROs with Spearman's correlation coefficients, adjusting all analyses for confounders. RESULTS: In the analyzable cohort (N=1265; 50.6% of the PBHS cohort), one standard deviation decreases in 17/18 walking measures were associated with greater likelihood for stage-B HF (multivariable-adjusted odds ratios [ORs] vs stage 0 ranging from 1.18-2.10), or A (ORs vs stage 0, 1.07-1.45), and lower likelihood for RF-/ECHO+ (ORs vs stage 0, 0.80-0.93). Peak 30-minute pace demonstrated the strongest associations with stage B (OR vs stage 0=2.10; 95% CI:1.74-2.53) and A (OR vs stage 0=1.43; 95% CI:1.23-1.66). Decreases in 13/18 measures were associated with greater likelihood for stage-B HF vs stage A. Strength of correlation with physical performance tests, echocardiographic cardiac-remodeling and dysfunction indices and PROs was greatest in stage B, then A, and lowest for 0. CONCLUSIONS: Digital measures of walking captured by wearable sensors could complement clinic-based testing to identify and monitor pre-symptomatic HF.

3.
JMIR Hum Factors ; 10: e48270, 2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37535417

RESUMO

BACKGROUND: Mobility is a meaningful aspect of an individual's health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. OBJECTIVE: Our objective was to characterize the analytical performance (accuracy and reliability) of a suite of digital measures of walking behaviors as critical aspects in the practical implementation of digital measures into clinical studies. METHODS: We collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without a history of gait or walking impairment in a real-world setting. On the basis of step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, and peak 30-minute walking pace. To characterize the accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4) with known low error, calculating the following metrics: intraclass correlation coefficient (ICC), Pearson r coefficient, mean error, and mean absolute error. To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time to reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1 to 30 days and analyzing test-retest reliability based on ICCs between adjacent (nonoverlapping) time windows for each measure. RESULTS: In the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (n=35 participants; median observation time 5 days). Agreement with the reference device-based readouts in the testing subcohort (n=35) for the 8 measurements under evaluation, as reflected by ICCs, ranged between 0.7 and 0.9; Pearson r values were all greater than 0.75, and all reached statistical significance (P<.001). For the time-to-reliability characterization, we collected data for a total of 15,120 participant-days (overall cohort N=234; median observation time 119 days). All digital measures achieved an ICC between adjacent readouts of >0.75 by 16 days of wear time. CONCLUSIONS: We characterized the accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide the practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions.

4.
Parkinsonism Relat Disord ; 109: 105355, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36905719

RESUMO

INTRODUCTION: Few late-stage clinical trials in Parkinson's disease (PD) have produced evidence on the clinical validity of sensor-based digital measurements of daily life activities to detect responses to treatment. The objective of this study was to assess whether digital measures from patients with mild-to-moderate Lewy Body Dementia demonstrate treatment effects during a randomized Phase 2 trial. METHODS: Substudy within a 12-week trial of mevidalen (placebo vs 10, 30, or 75 mg), where 70/344 patients (comparable to the overall population) wore a wrist-worn multi-sensor device. RESULTS: Treatment effects were statistically significant by conventional clinical assessments (Movement Disorder Society-Unified Parkinson's Disease Rating Scale [MDS-UPDRS] sum of Parts I-III and Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change [ADCS-CGIC] scores) in the full study cohort at Week 12, but not in the substudy. However, digital measurements detected significant effects in the substudy cohort at week 6, persisting to week 12. CONCLUSIONS: Digital measurements detected treatment effects in a smaller cohort over a shorter period than conventional clinical assessments. TRIAL REGISTRATION: clinicaltrials.gov, NCT03305809.


Assuntos
Doença de Alzheimer , Doença por Corpos de Lewy , Doença de Parkinson , Humanos , Doença por Corpos de Lewy/tratamento farmacológico , Punho , Doença de Parkinson/tratamento farmacológico , Doença de Parkinson/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...