Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
2.
Heart Rhythm O2 ; 5(3): 158-167, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560372

RESUMO

Background: Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed. Results: A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years. Conclusion: Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

7.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37595138

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. METHODS AND RESULTS: We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13-54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305-1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713-4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070-2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235-2.090; P < 0.001). CONCLUSIONS: Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Fármacos Cardiovasculares , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos
8.
Mayo Clin Proc ; 98(7): 1042-1053, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37419573

RESUMO

With an aging population and an explosion in ambulatory electrocardiographic monitoring, primary care clinicians will undoubtedly see an increase in patients presenting with premature ventricular complexes (PVCs), especially given how common they are in the general population. A sizable number of patients with PVCs are asymptomatic, and these PVCs have no significant clinical implications. In contrast, PVCs can predispose patients to or are a clinical marker of an underlying cardiomyopathy, heart failure, or sudden cardiac death. Such a dichotomy can create fear in dealing with PVCs in the outpatient setting, both in immediate situations and for surveillance and follow-up. In this review, we provide a comprehensive overview of the pathophysiologic basis of PVCs, appropriate diagnostic testing, management, and prognostic considerations necessary when faced with PVCs in the outpatient clinic. We also provide a simplistic approach to help guide the initial work-up of PVCs, basic treatment strategies, and indications of when to refer for cardiovascular specialty consultation to improve physician comfort and to enhance patient care.


Assuntos
Cardiomiopatias , Complexos Ventriculares Prematuros , Humanos , Idoso , Pacientes Ambulatoriais , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/terapia , Coração , Eletrocardiografia Ambulatorial
9.
Minerva Med ; 114(6): 839-849, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37338231

RESUMO

With burgeoning evidence for early rhythm control in patients with atrial fibrillation (AF), the management of AF in the outpatient setting has become more challenging. The primary care clinician often serves as the frontline in the pharmacologic management of AF. Because of drug interactions and the risk of proarrhythmia, many clinicians remain hesitant about the initiation and chronic management of antiarrhythmic drug prescriptions. However, with the likely increased use of antiarrhythmics for early rhythm control, understanding and familiarity with these medications have likewise become more important, especially since patients with AF probably have other non-cardiac medical conditions that can impact their antiarrhythmic therapy. In this comprehensive review, we provide informative, high-yield cases and edifying references that will help primary care providers become comfortable handling various clinical scenarios.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Pacientes Ambulatoriais
10.
JACC Clin Electrophysiol ; 9(5): 697-700, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37204352

RESUMO

Intrinsic antitachycardia pacing (iATP) is a novel, automated antitachycardia pacing (ATP) algorithm that provides individualized therapy to terminate ventricular tachycardia (VT). If the first ATP attempt is unsuccessful, the algorithm analyzes the tachycardia cycle length and the postpacing interval and adjusts the subsequent sequence to successfully terminate VT. This algorithm was effective in a single clinical study without a comparator arm. However, iATP failure has not been well-documented in the literature. This publication represents the first case series with episode analysis of iATP failure, including a demonstration of its proarrhythmic effect.


Assuntos
Estimulação Cardíaca Artificial , Taquicardia Ventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Taquicardia Ventricular/terapia , Algoritmos , Trifosfato de Adenosina
11.
medRxiv ; 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37214896

RESUMO

Background: Cardiovascular implantable electronic devices (CIEDs) such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: Describe trends in noninfectious CIED complications over the past three decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966-current. CIED implants between 1988-2018 were determined. Trends in noninfectious complications within 30 days of implant were analyzed. Results: 175 out of 2536 (6.9%) patients who received CIED experienced device complications. 3.8% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.9%), followed by hematoma (2.1%). Complications went up from 1988 to 2005, then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (p<0.01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity score has trended up over the 30 years. Conclusions: Our study describes a real-world trend of CIED complications over three decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

12.
Pulm Circ ; 12(4): e12147, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36325510

RESUMO

We present a novel description of Bezold-Jarisch Reflex (BJR) during cardiopulmonary exercise testing (CPET) in three young female patients with Group 1 pulmonary arterial hypertension (PAH). These three cases presented within 26 months, representing only 0.8% of 11,387 tests on patients with PAH undergoing CPET during this time frame.

13.
Curr Heart Fail Rep ; 19(6): 435-444, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36205832

RESUMO

PURPOSE OF REVIEW: To evaluate remote monitoring using implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) devices as an adjunctive tool to the traditional care of patients with heart failure (HF). RECENT FINDINGS: We included 11 trials encompassing 5965 patients. Absolute risk difference (ARD) with 95% credible interval (CrI) was estimated. Pooled (posterior) risk difference was computed using Bayesian hierarchical methods. The ARD for mortality was centered at - 0.01 (95% CrI: - 0.03; 0.01, Tau: 0.02), with an 82% probability of ARD of ICD/CRT-D remote monitoring with respect to control being less than 0. The ARD for cardiovascular mortality was centered at - 0.03 (95% CrI: - 0.11; 0.05, Tau: 0.10), with an 84% probability of ARD of ICD/CRT-D remote monitoring with respect to control being less than 0. ICD/CRT-D remote monitoring in patients with HF is associated with a higher probability of reduced all-cause and cardiovascular mortality compared with standard care alone.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Teorema de Bayes , Volume Sistólico , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
14.
Heart Rhythm O2 ; 3(4): 385-392, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097458

RESUMO

Background: Heart block requiring permanent pacemaker (PPM) implantation is a relatively frequent complication of transcatheter aortic valve replacement (TAVR). Objective: The purpose of this study was to perform a contemporary meta-analysis to provide an updated assessment of clinically useful predictors of PPM implantation post-TAVR. Methods: Medline and EMBASE searches were performed to include all studies reporting PPM post-TAVR between 2015 and 2020. Pertinent data were extracted from the studies for further analysis. RevMan was used to create forest plots and calculate risk ratios (RRs). Results: We evaluated 41 variables from 239 studies with a total of 981,168 patients. From this cohort, 17.4% received a PPM following TAVR. Strong predictors for PPM implant were right bundle branch block (RBBB) (RR 3.12; P <.001) and bifascicular block (RR 2.40; P = .002). Intermediate factors were chronic kidney disease (CKD) (RR 1.53; P <.0001) and first-degree atrioventricular block (FDAVB) (RR 1.44; P <.001). Weak factors (RR 1-1.50; P <.05) were male gender, age ≥80 years, body mass index ≥25, diabetes mellitus (DM), atrial fibrillation (AF), and left anterior fascicular block (LAFB). These factors along with increased left ventricular outflow tract (LVOT) area (>435 mm2) and/or aortic annulus diameter (>24.4 mm) were incorporated to propose a new scoring system to stratify patients into high- and low-risk groups. Conclusion: Male gender, age ≥80 years, FDAVB, RBBB, AF, DM, CKD, Medtronic CoreValve, transfemoral TAVR, increased LVOT, and aortic annulus diameter were significant predictors of post-TAVR PPM implantation. Preprocedural assessment should consider these factors to guide clinical decision-making before TAVR. Validation of our scoring system is warranted.

15.
Front Cardiovasc Med ; 9: 978341, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36148047

RESUMO

Background: Strain imaging has been suggested as a tool to detect early left ventricular (LV) dysfunction due to frequent premature ventricular contractions (PVCs) in patients with preserved LV ejection fraction (EF). However, the progression of intraventricular dyssynchrony (IVD), radial, and circumferential strain (RS, CS) in PVC-cardiomyopathy (CM) are unknown. The aim of this study was to elucidate the progression patterns of CS, IVD, and electro-mechanical latency (EML) in PVC-CM. Methods and results: Pacemakers were implanted in 20 canines to reproduce ventricular bigeminy at 200ms (PVCs n = 11) for 12 weeks and compared to a sham group (n = 9). We obtained echocardiograms at baseline, 4-, 8- and 12-weeks. RS and CS were obtained at the LV mid-cavitary level. IVD was defined as the time between the earliest and latest peak RS. EML was defined as the time between the onset of QRS and the earliest peak RS. LVEF (62 ± 5 to 42 ± 7%, p < 0.01), CS (-18 ± 3 to -12 ± 3, p < 0.01), and EML (219 ± 37 to 283 ± 46ms, p = 0.02) changed significantly in the PVC group. Peak CS (-18 ± 3 to -14 ± 4, p = 0.02) and IVD (49 ± 31 to 122 ± 103, p = 0.05) had a significant change at 4-weeks despite preserved LVEF (51 ± 5%). IVD normalized while EML increased at weeks 8 and 12. Conclusion: Our findings consolidate the existing theory that changes in strain precede changes in LVEF in PVC-CM. While IVD becomes abnormal early in the development of PVC-CM, it pseudo-normalizes at advanced stages due to further increases in EML suggestive of cardiac contractility remodeling. These findings are consistent with recent published data where abnormal LV mechanics could be part of a substrate that can predispose to worse outcome in PVC-Cardiomyopathy.

16.
J Interv Card Electrophysiol ; 65(3): 751-756, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35963910

RESUMO

BACKGROUND: The aim of this study was to assess the safety, efficacy, and predictors of outcomes for atrial fibrillation (AF) ablation in patients with a history of breast cancer. METHODS: Consecutive patients with a history of breast cancer undergoing AF ablation from January 2010 to December 2021 were propensity matched in a 1:1 ratio to patients without a history of any cancer. The primary outcome was procedural efficacy, defined by clinical AF recurrence and repeat catheter ablation. The secondary outcome was an assessment of safety looking at eight peri-procedural events. RESULTS: Our cohort was comprised of 82 female patients, 41 patients with a history of breast cancer (mean age, 74.6 ± 7.4 years), and 41 patients with no history of cancer (76.7 ± 8.1 years). Both groups had similar echocardiographic, baseline, and arrhythmia characteristics. Breast cancer patients were at an increased risk of AF recurrence post-ablation compared to non-cancer patients (OR 2.68, 95% CI 1.05-6.86, p = 0.04). Multivariate analysis found prior mediastinal radiotherapy (OR 4.79, 95% CI 1.34-17.1) and AF diagnosis to ablation time (OR 1.2, 95% CI 1.03-1.29) were both independent predictors of AF recurrence post-ablation. CONCLUSION: Our study suggests that female patients with a history of breast cancer are at a higher risk of developing AF recurrence after catheter ablation. Multivariate analysis showed that patients with a history of prior mediastinal radiation therapy and AF diagnosis to time to ablation were both independent risk factors.


Assuntos
Fibrilação Atrial , Neoplasias da Mama , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Fatores de Risco
17.
J Cardiovasc Electrophysiol ; 33(5): 982-993, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233867

RESUMO

AIMS: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. METHODS: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%. RESULTS: Sixty-five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4-wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. CONCLUSION: With the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.


Assuntos
Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Ecocardiografia , Átrios do Coração , Ventrículos do Coração , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 8(1): 88-100, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34454890

RESUMO

OBJECTIVES: This study sought to describe trends in cardiovascular implantable electronic device (CIED) insertion over the past 3 decades in Olmsted County. BACKGROUND: Trends in CIED insertion in the United States have not been extensively studied. METHODS: The Rochester Epidemiology Project is a medical records linkage system comprising the records of all residents of Olmsted County from 1966 to the present. CIED insertion between 1988 and 2018 was determined using International Classification of Diseases-Ninth Revision, International Classification of Diseases-10th Revision, and Current Procedural Terminology codes. Age- and sex-adjusted incidence rates, adjusted to the 2010 US White population, were calculated. Trends in incidence over time, across age groups, and between sex are estimated using Poisson regression models. RESULTS: The age- and sex-adjusted incidence of device implants for the study period were as follows: overall CIED: 82.4 (95% CI: 79.2-85.6); permanent pacemaker (PPM): 62.9 (95% CI: 60.0-65.7); implantable cardioverter-defibrillator (ICD): 14.0 (95% CI: 12.6-15.3); and cardiac resynchronization therapy (CRT): 5.6 (95% CI: 4.7-6.4) per 100,000 per year. The overall incidence of CIED insertion increased between 1988 to 1993 and 2000 to 2005 and then decreased between 2000 to 2005 and 2012 to 218 (P < 0.0001). PPM and ICD insertion incidence followed these trends, whereas the incidence of CRT insertion increased between 2000 to 2005 and 2012 to 2018. CIED insertion incidence increased with age (P < 0.0001). CIED insertion incidence was greater in men (116.3 vs 57.3 per 100,000 per year in men vs women; P < 0.0001). The overall survival of CRT recipients improved (P = 0.0044). CONCLUSIONS: The incidence values for PPM and ICD implants are decreasing, while the incidence of CRT implants is increasing. CIEDs are increasingly inserted in the elderly, men, and patients with higher comorbidities.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Eletrônica , Feminino , Humanos , Masculino , Fatores de Risco , Estados Unidos/epidemiologia
20.
J Cardiovasc Electrophysiol ; 33(2): 176-177, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34897873

RESUMO

Catheter ablation for atrial fibrillation has emerged as a mainstay for the management of atrial fibrillation. It has been shown to be clinically effective and cost-effective in multiple trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...