Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959423

RESUMO

Due to a great interest in the beneficial properties of polyphenolic antioxidant curcumin (CCM), sensitive and accurate methods for determining CCM are needed. The purpose of our research was to develop a very simple, fast, and sensitive differential pulse adsorptive stripping voltammetric (DPAdSV) procedure using an electrochemically activated screen-printed boron-doped diamond electrode (aSPBDDE) for the determination of CCM. The activation of the SPBDDE was accomplished in a solution of 0.1 mol/L NaOH by performing five cyclic voltammetric scans in the range of 0-2 V, at ν of 100 mV/s. The changes in surface morphology and the reduction of the charge transfer resistance due to the activation of the electrode resulted in the amplification of the CCM analytical signal on the aSPBDDE. As a result, an extremely sensitive measurement tool was formed, which under optimized conditions (0.025 mol/L PBS of pH = 2.6, Eacc of 0.3 V, tacc of 90 s, ΔEA of 100 mV, ν of 150 mV/s, and tm of 10 ms) allowed us to obtain a limit of detection (LOD) of 5.0 × 10-13 mol/L. The aSPBDDE has proven to be a highly effective tool for the direct determination of CCM in food samples with high accuracy and precision. The results are in agreement with those obtained using ultra-high-performance liquid chromatography coupled with mass spectrometry and electrospray ionization (UHPLC-ESI/MS).

2.
Sensors (Basel) ; 22(21)2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36365906

RESUMO

The paper presents a very simple way to extremely improve the sensitivity of trace V(V) determination. The application of a new supporting electrolyte composition (CH3COONH4, CH3COOH, and NH4Cl) instead of the commonly used acetate buffer (CH3COONa and CH3COOH) significantly enhanced the adsorptive stripping voltammetric signal of vanadium(V) at the lead-coated glassy carbon electrode (GCE/PbF). A higher enhancement was attained in the presence of cupferron as a complexing agent (approximately 10 times V(V) signal amplification) than in the case of chloranilic acid and bromate ions (approximately 0.5 times V(V) signal amplification). Therefore, the adsorptive stripping voltammetric system with the accumulation of V(V)-cupferron complexes at -1.1 V for 15 s in the buffer solution (CH3COONH4, CH3COOH, and NH4Cl) of pH = 5.6 ± 0.1 was selected for the development of a simple and extremely sensitive V(V) analysis procedure. Under optimized conditions, the sensitivity of the procedure was 6.30 µA/nmol L-1. The cathodic peak current of V(V) was directly proportional to its concentration in the ranges of 1.0 × 10-11 to 2.0 × 10-10 mol L-1 and 2.0 × 10-10 to 1.0 × 10-8 mol L-1. Among the electrochemical procedures, the lowest detection limit (2.8 × 10-12 mol L-1) of V(V) was obtained for the shortest accumulation time (15 s). The high accuracy of the procedure was confirmed on the basis of the analysis of certified reference material (estuarine water) and river water samples.


Assuntos
Carbono , Vanádio , Carbono/química , Eletrodos , Água
3.
Materials (Basel) ; 15(14)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35888414

RESUMO

Testosterone (TST), despite its good properties, may be harmful to the human organism and the environment. Therefore, monitoring biological fluids and environmental samples is important. An electrochemically pretreated screen-printed carbon sensor modified with Pb nanoparticles (pSPCE/PbNPs) was successfully prepared and used for the determination of TST. The surface morphology and electrochemical properties of unmodified and modified sensors were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning and transmission electron microscopy (SEM and TEM), and energy-dispersive X-ray spectroscopy (EDS). Selective determinations of TST at the pSPCE/PbNPs were carried out by differential pulse adsorptive stripping voltammetry (DPAdSV, EPb dep.and TST acc. of -1.1 V, t Pb dep.and TST acc. of 120 s, ΔEA of 50 mV, ν of 175 mV s-1, and tm of 5 ms) in a solution containing 0.075 mol L-1 acetate buffer of pH = 4.6 ± 0.1, and 7.5 × 10-5 mol L-1 Pb(NO3)2. The analytical signal obtained at the potential around -1.42 V (vs. silver pseudo-reference electrode) is related to the reduction process of TST adsorbed onto the electrode surface. The use of pSPCE/PbNPs allows obtaining a very low limit of TST detection (2.2 × 10-12 mol L-1) and wide linear ranges of the calibration graph (1.0 × 10-11-1.0 × 10-10, 1.0 × 10-10-2.0 × 10-9, and 2.0 × 10-9-2.0 × 10-8 mol L-1). The pSPCE/PbNPs were successfully applied for the determination of TST in reference material of human urine and wastewater purified in a sewage treatment plant without preliminary preparation.

4.
Sensors (Basel) ; 22(7)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35408052

RESUMO

The dynamic production and usage of pharmaceuticals, mainly painkillers, indicates the growing problem of environmental contamination. Therefore, the monitoring of pharmaceutical concentrations in environmental samples, mostly aquatic, is necessary. This article focuses on applying screen-printed voltammetric sensors for the voltammetric determination of painkillers residues, including non-steroidal anti-inflammatory drugs, paracetamol, and tramadol in environmental water samples. The main advantages of these electrodes are simplicity, reliability, portability, small instrumental setups comprising the three electrodes, and modest cost. Moreover, the electroconductivity, catalytic activity, and surface area can be easily improved by modifying the electrode surface with carbon nanomaterials, polymer films, or electrochemical activation.


Assuntos
Nanoestruturas , Água , Carbono/química , Eletrodos , Nanoestruturas/química , Reprodutibilidade dos Testes
5.
Int J Mol Sci ; 23(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35269572

RESUMO

In this paper, we propose the first analytical procedure-using a screen-printed carbon electrode modified with carbon nanofibers (SPCE/CNFs)-for the detection and quantitative determination of an electroactive disubstituted fused triazinone, namely 4-Cl-PIMT, which is a promising anticancer drug candidate. The electrochemical performances of the sensor were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square-wave adsorptive stripping voltammetry (SWAdSV). The presence of carbon nanofibers on the sensor surface caused a decrease in charge-transfer resistance and an increase in the active surface compared to the bare SPCE. Under the optimised experimental conditions, the proposed voltammetric procedure possesses a good linear response for the determination of 4-Cl-PIMT in the two linear ranges of 0.5-10 nM and 10-100 nM. The low limits of detection and quantification were calculated at 0.099 and 0.33 nM, respectively. In addition, the sensor displays high reproducibility and repeatability, as well as good selectivity. The selectivity was improved through the use of a flow system and a short accumulation time. The SWAdSV procedure with SPCE/CNFs was applied to determine 4-Cl-PIMT in human serum samples. The SWAdSV results were compared to those obtained by the ultra-high-performance liquid chromatography coupled with electrospray ionization/single-quadrupole mass spectrometry (UHPLC-ESI-MS) method.


Assuntos
Antineoplásicos/análise , Carbono/química , Técnicas Eletroquímicas/instrumentação , Triazinas/análise , Espectroscopia Dielétrica , Eletrodos , Humanos , Limite de Detecção , Estrutura Molecular , Nanofibras/química , Propriedades de Superfície
6.
Int J Mol Sci ; 24(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36613924

RESUMO

In this paper, we report a highly sensitive voltammetric sensor for the determination of the anti-cancer antibiotic bleomycin (BLM) based on a screen-printed carbon sensor that is electrochemically pretreated and decorated with lead nanoparticles in the sample solution (pSPCE/PbNPs). These sensor surface manipulations contribute to significant amplification of the analytical signal and improvement of its shape and repeatability. The effect of the electrochemical behavior of BLM on the pSPCE/PbNPs was examined by electrochemical strategies. CV, EIS, and XPS were used to compare the sensor surface modifications. The effects of the type and pH of the supporting electrolyte and the procedure parameters were optimized. The features of the proposed procedure include: (a) very low limits of detection and quantification (2.8 × 10-11 and 9.3 × 10-11 M, respectively), (b) linear ranges (1.0 × 10-10-2.0 × 10-9 M and 2.0 × 10-9-2.0 × 10-8 M, and (c) a high sensitivity of 0.32 µA/nM. The electrochemical sensor was successfully applied for the determination of BLM in wastewater and reference material of human urine samples.


Assuntos
Bleomicina , Nanopartículas Metálicas , Humanos , Eletrodos , Antibacterianos , Técnicas Eletroquímicas
7.
Int J Mol Sci ; 24(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36614007

RESUMO

3-(4-Nitrophenyl)-8-(2,3-dimethylphenyl)-7,8-dihydroimidazo[2,1-c][1,2,4]triazin-4(6H)-one (NDIT) is one of the most promising candidates for anticancer agents. Hence, a sensitive and selective sodium dodecyl sulfate-modified screen-printed carbon sensor (SPCE/SDS) was used for its quantitative analysis. The SPCE/SDS, in contrast to the SPCE, showed excellent behavior in the electrochemical reduction of NDIT by differential-pulse adsorptive stripping voltammetry (DPAdSV). Cyclic voltammetric (CV) studies reveal an irreversible, two-stage and not purely diffusion-controlled reduction process in 0.01 M HNO3. The sensor was characterized by CV and electrochemical impedance spectroscopy (EIS). Under the optimized conditions (t 45 s, ΔE 175 mV, ν 150 mV/s, and tm 5 ms), the DPAdSV procedure with the SPCE/SDS presented a very wide linear range from 1 to 2000 nM and a low detection limit of 0.29 nM. A 1000-fold excess concentration of potential interferents commonly present in biological samples did not significantly alter the peak current of NDIT. The practical application of the proposed DPAdSV procedure with the SPCE/SDS was successfully checked by analyzing spiked human serum samples.


Assuntos
Carbono , Tensoativos , Humanos , Carbono/química , Eletrodos , Dodecilsulfato de Sódio , Técnicas Eletroquímicas/métodos
8.
Materials (Basel) ; 14(21)2021 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-34772017

RESUMO

In this paper, a dicyandiamide-impregnated mesoporous carbon (N-CMK-3), electrochemically modified in situ with lead film (Pb-N-CMK-3), was tested as an electrode material for U(VI) ultratrace determination. The prepared carbon material was characterized by XRD, SEM-EDX, Raman, FT-IR, XPS analysis and nitrogen sorption measurements. The changes of electrochemical properties of glassy carbon electrodes (GCE) after the N-CMK-3 and Pb-N-CMK-3 modification were studied using CV and EIS methods. The modification of the GCE surface by the N-CMK-3 material and Pb film increases the electroactive area of the electrode and decreases the charge transfer residence and is likely responsible for the electrochemical improvement of the U(VI) analytical signal. Using square-wave adsorptive stripping voltammetry (SWAdSV), two linear calibration ranges extending from 0.05 to 1.0 nM and from 1.0 to 10.0 nM were observed, coupled with the detection and quantification limits of 0.014 and 0.047 nM, respectively. The Pb-N-CMK-3/GCE was successfully applied for U(VI) determination in reference materials (estuarine water SLEW-3 and trace elements in natural water SRM 1640a).

9.
Materials (Basel) ; 14(15)2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34361425

RESUMO

In this paper, a screen-printed boron-doped electrode (aSPBDDE) was subjected to electrochemical activation by cyclic voltammetry (CV) in 0.1 M NaOH and the response to rifampicin (RIF) oxidation was used as a testing probe. Changes in surface morphology and electrochemical behaviour of RIF before and after the electrochemical activation of SPBDDE were studied by scanning electron microscopy (SEM), CV and electrochemical impedance spectroscopy (EIS). The increase in number and size of pores in the modifier layer and reduction of charge transfer residence were likely responsible for electrochemical improvement of the analytical signal from RIF at the SPBDDE. Quantitative analysis of RIF by using differential pulse adsorptive stripping voltammetry in 0.1 mol L-1 solution of PBS of pH 3.0 ± 0.1 at the aSPBDDE was carried out. Using optimized conditions (Eacc of -0.45 V, tacc of 120 s, ΔEA of 150 mV, ν of 100 mV s-1 and tm of 5 ms), the RIF peak current increased linearly with the concentration in the four ranges: 0.002-0.02, 0.02-0.2, 0.2-2.0, and 2.0-20.0 nM. The limits of detection and quantification were calculated at 0.22 and 0.73 pM. The aSPBDDE showed satisfactory repeatability, reproducibility, and selectivity towards potential interferences. The applicability of the aSPBDDE for control analysis of RIF was demonstrated using river water samples and certified reference material of bovine urine.

10.
Materials (Basel) ; 14(13)2021 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-34206920

RESUMO

In this work, an electrochemically activated screen-printed carbon electrode modified with sodium dodecyl sulfate (aSPCE/SDS) was proposed for the simultaneous determination of paracetamol (PA), diclofenac (DF), and tramadol (TR). Changes of surface morphology and electrochemical behaviour of the electrode after the electrochemical activation with H2O2 and SDS surface modification were studied by scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The influence of various parameters on the responses of the aSPCE/SDS such as pH and concentration of the buffer, SDS concentration, and techniques parameters were investigated. Using optimised conditions (Eacc. of -0.4 V, tacc. of 120 s, ΔEA of 150 mV, ν of 250 mV s-1, and tm of 10 ms), the aSPCE/SDS showed a good linear response in the concentration ranges of 5.0 × 10-8-2.0 × 10-5 for PA, 1.0 × 10-9-2.0 × 10-7 for DF, and 1.0 × 10-8-2.0 × 10-7 and 2.0 × 10-7-2.0 × 10-6 mol L-1 for TR. The limits of detection obtained during the simultaneous determination of PA, DF, and TR are 1.49 × 10-8 mol L-1, 2.10 × 10-10 mol L-1, and 1.71 × 10-9 mol L-1, respectively. The selectivity of the aSPCE/SDS was evaluated by examination of the impact of some inorganic and organic substances that are commonly present in environmental and biological samples on the responses of PA, DF, and TR. Finally, the differential pulse adsorptive stripping voltammetric (DPAdSV) procedure using the aSPCE/SDS was successfully applied for the determination of PA, DF, and TR in river water and serum samples as well as pharmaceuticals.

11.
Int J Tryptophan Res ; 14: 11786469211023468, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34276216

RESUMO

Nowadays, development of analytical methods responding to a need for rapid and accurate determination of human metabolites is highly desirable. Herein, an electrochemical method employing a Nafion-coated glassy carbon electrode (Nafion/GCE) has been developed for reliable determination of kynurenine (a key tryptophan metabolite) using a differential pulse adsorptive stripping voltammetry. To our knowledge, this is the first analytical method to allow for kynurenine determination at the Nafion-coated electrode. The methodology involves kynurenine pre-concentration in 0.1 M H2SO4 in the Nafion film at the potential of +0.5 V and subsequent stripping from the electrode by differential pulse voltammetry. Under optimal conditions, the sensor can detect 5 nM kynurenine (for the accumulation time of 60 seconds), but the limit of detection can be easily lowered to 0.6 nM by prolonging the accumulation time to 600 seconds. The sensor shows sensitivity of 36.25 µAµM-1cm-2 and 185.50 µAµM-1cm-2 for the accumulation time of 60 and 600 seconds, respectively. The great advantage of the proposed method is easy sensor preparation, employing drop coating method, high sensitivity, short total analysis time, and no need for sample preparation. The method was validated for linearity, precision, accuracy (using a high-performance liquid chromatography), selectivity (towards tryptophan metabolites and different amino acids), and recovery. The comprehensive microscopic and electrochemical characterization of the Nafion/GCE was also conducted with different methods including atomic force microscopy (AFM), optical profilometry, time-of-flight secondary ion mass spectrometry (TOF-SIMS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The method has been applied with satisfactory results for determination of kynurenine concentration in a culture medium collected from the human ovarian carcinoma cells SK-OV-3 and to measure IDO enzyme activity in the cancer cell extracts.

12.
Sensors (Basel) ; 20(18)2020 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-32933116

RESUMO

A carbon nanofibers modified screen-printed carbon sensor (SPCE/CNFs) was applied for the determination of a novel promising anticancer agent candidate (ethyl 8-(4-methoxyphenyl)-4-oxo-4,6,7,8-tetrahydroimidazo[2,1-c][1,2,4]triazine-3-carboxylate, EIMTC) using square-wave voltammetry (SWV). It is the first method for the quantitative determination of EIMTC. The modified screen-printed sensor exhibited excellent electrochemical activity in reducing EIMTC. The peak current of EIMTC was found to be linear in two concentration ranges of 2.0 × 10-9 - 2.0 × 10-8 mol L-1 and 2.0 × 10-8 - 2.0 × 10-7 mol L-1, with a detection limit of 5.0 × 10-10 mol L-1. The connection of flow-cell for the SPCE/CNFs with SWV detection allowed for the successful determination of EIMTC in human serum samples. Ultra-high-performance liquid chromatography coupled to electrospray ionization triple quadrupole mass spectrometry (UHPLC-ESI-MS/MS) acted as a comparative method in the serum samples analysis.


Assuntos
Antineoplásicos , Nanofibras , Carbono , Eletrodos , Humanos , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...