Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Regul Toxicol Pharmacol ; 100: 35-44, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30291877

RESUMO

Protein therapeutics represent a rapidly growing proportion of new medicines being developed by the pharmaceutical industry. As with any new drug, an Occupational Exposure Limit (OEL) should be developed to ensure worker safety. Part of the OEL determination addresses bioavailability (BA) after inhalation, which is poorly understood for protein therapeutics. To explore this, male Sprague-Dawley rats were exposed intravenously or by nose-only inhalation to one of five test proteins of varying molecular size (10-150 kDa), including a polyethylene glycol-conjugated protein. Blood, lung tissue and bronchoalveolar lavage (BAL) fluid were collected over various time-points depending on the expected test protein clearance (8 minutes-56 days), and analyzed to determine the pharmacokinetic profiles. Since the BAL half-life of the test proteins was observed to be > 4.5 h after an inhalation exposure, accumulation and direct lung effects should be considered in the hazard assessment for protein therapeutics with lung-specific targets. The key finding was the low systemic bioavailability after inhalation exposure for all test proteins (∼≤1%) which did not appear molecular weight-dependent. Given that this study examined the inhalation of typical protein therapeutics in a manner mimicking worker exposure, a default 1% BA assumption is reasonable to utilize when calculating OELs for protein therapeutics.


Assuntos
Polietilenoglicóis/farmacocinética , Proteínas/farmacocinética , Administração por Inalação , Animais , Disponibilidade Biológica , Líquido da Lavagem Broncoalveolar/química , L-Lactato Desidrogenase/metabolismo , Pulmão/metabolismo , Masculino , Concentração Máxima Permitida , Ratos Sprague-Dawley , Receptores Fc/metabolismo
2.
AAPS J ; 19(5): 1461-1468, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28589510

RESUMO

The bioanalytical strategy for monoclonal antibody therapeutics, intended for multiple oncology indications, includes multiple integrated measurements of pharmacologically relevant therapeutics from discovery through development. Three ligand binding assays were cohesively developed and validated, as applicable, using the Gyrolab microfluidic system for the measurement of a free monoclonal antibody BMS-986207. Accuracy and precision demonstrate %bias from -6.3 to 4.4%, percent coefficient of variation (%CV) from 2.6 to 9.8%, and total error from 4.2 to 13.4% in the nonclinical assay; %bias from -0.3 to 3.3%, %CV from 3.5 to 18.2%, and total error from 6.1 to 19.7% in the clinical assay; and >97% of the sample meeting incurred sample reanalysis criteria. The clinical assay was validated using singlicate wells after gaining significant data in the early phase studies to support this cost-effective and efficient strategy. Each assay met fit-for-purpose and/or regulated bioanalytical method validation criteria including stability, selectivity, dilutional linearity, carryover, and specificity criteria with no interference from co-administered monoclonal antibody.


Assuntos
Anticorpos Monoclonais/análise , Microfluídica/métodos , Humanos , Ligantes
3.
Bioanalysis ; 8(6): 519-31, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26915587

RESUMO

BACKGROUND: The bioanalytical strategy for antibody-drug conjugates (ADC) includes multiple integrated measurements of pharmacologically relevant ADC. METHODS & RESULTS: Three ligand-binding assays were validated for the measurement of total antibody, active ADC and total ADC. Accuracy and precision demonstrate %bias from -8 to 14%, %CV from 3 to 11% and total error from 3 to 21%, with >98% samples meeting incurred sample reanalysis criteria. Each assay met stability, selectivity, dilutional integrity, carry over and specificity criteria with no interference from associated metabolite/impurity. Given the active ADC assay sensitivity to payload, active ADC was used to assess drug to antibody ratio. DISCUSSION & CONCLUSION: Implementation of a microfluidic automated platform enabled high throughput sample analysis of multiple analytes with minimal sample processing.


Assuntos
Imunoensaio , Imunoconjugados/análise , Anticorpos Monoclonais/química , Meia-Vida , Imunoensaio/normas , Imunoconjugados/farmacocinética , Lignanas , Preparações Farmacêuticas/química , Controle de Qualidade
4.
Leuk Res ; 33(3): 465-73, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18835037

RESUMO

We have compared the cytotoxic activity of rituximab with that of blinatumomab (MT103/MEDI-538), a single-chain CD19-/CD3-bispecific antibody engaging human T cells. Blinatumomab consistently led to a higher degree of lysis of human lymphoma lines than rituximab, and was active at much lower concentration. The cytotoxicity mediated by blinatumomab and rituximab both caused a potent activation of pro-caspases 3 and 7 in target cells, a key event in induction of granzyme-mediated apoptotic cell death. Combination of rituximab with blinatumomab was found to greatly enhance the activity of rituximab, in particular at low effector-to-target cell ratios and at low antibody concentration.


Assuntos
Anticorpos Biespecíficos/farmacologia , Anticorpos Monoclonais/farmacologia , Citotoxicidade Imunológica/efeitos dos fármacos , Anticorpos Monoclonais Murinos , Antígenos CD19/imunologia , Protocolos de Quimioterapia Combinada Antineoplásica , Complexo CD3/imunologia , Caspase 3/metabolismo , Caspase 7/metabolismo , Sinergismo Farmacológico , Granzimas , Humanos , Linfoma de Células B/tratamento farmacológico , Linfoma de Células B/patologia , Rituximab , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...