Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Sports Exerc ; 55(8): 1366-1374, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36921110

RESUMO

PURPOSE: This study assessed the effects of the COVID-19 pandemic restrictions/lockdowns on physical activity levels, body mass, quadriceps strength, and gait biomechanics over 18 months. METHODS: Ten healthy men were assessed at baseline (~14 wk before first lockdown) and 17.9 ± 0.3 months later (<1 wk after second lockdown). At both times, physical activity levels, body mass, and quadriceps strength were acquired using the International Physical Activity Questionnaire, a force plate, and a dynamometer, respectively. Gait data were also acquired using a motion capture system and force plates during self-paced walking, from which spatiotemporal parameters, knee angles, and external moments were computed. Baseline and follow-up measurements were compared using two-tailed paired t -tests ( α = 0.05). RESULTS: At follow-up, participants spent less time doing vigorous physical activity (∆ = -76 ± 157 min·wk -1 , P = 0.048), exhibited a tendency toward increased sedentary time (∆ = +120 ± 162 min·d -1 , P = 0.056), weighed more (∆ = +2.5 ± 2.8 kg, P = 0.021), and showed a trend toward reduced quadriceps strength (∆ = -0.29 ± 0.45 (N·m)·kg -1 , P = 0.071) compared with baseline. At follow-up, participants walked slower (∆ = -0.09 ± 0.07 m·s -1 , P = 0.005), had greater knee flexion angles at heel strike (∆ = +2.2° ± 1.8°, P = 0.004) and during late stance (∆ = +2.2° ± 1.8°, P = 0.004), had reduced knee extension moments (∆ = -0.09 ± 0.09 (N·m)·kg -1 , P = 0.012) and knee internal rotation moments (∆ = -0.02 ± 0.02 (N·m)·kg -1 , P = 0.012) during late stance. CONCLUSIONS: Healthy men exhibited reduced physical activity levels, increased body weight, a tendency toward reduced quadriceps strength, and altered gait biomechanics over the initial 18 months of the COVID-19 pandemic-alterations that could have far-reaching health consequences.


Assuntos
COVID-19 , Pandemias , Masculino , Humanos , Fenômenos Biomecânicos , Força Muscular , Controle de Doenças Transmissíveis , Marcha , Articulação do Joelho , Caminhada , Músculo Quadríceps , Peso Corporal
2.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1247-1266, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34601628

RESUMO

PURPOSE: Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post-operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient-specific episealer implants. This study hypothesized that patient-specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion. METHODS: Retrospective study design. Fluoroscopic analysis during unloaded flexion-extension and loaded lunge was conducted at > 12 months post-surgery in ten episealer knees, and compared to ten healthy knees. Pre- and post-operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires. RESULTS: A consistent medial pivot was observed in both episealer and healthy knees. Non-significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1-year post-surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004). CONCLUSION: At 12 month follow-up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post-operative muscle weakness and consequent insufficient stabilization at high flexion.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Humanos , Estudos Retrospectivos , Projetos Piloto , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos
3.
Z Med Phys ; 32(4): 500-513, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35221155

RESUMO

INTRODUCTION: This work aimed to develop a novel multipurpose device for guided knee flexion-extension, both passively using a motorized pneumatic system and actively (muscle-driven) with the joint unloaded or loaded during dynamic MRI. Secondary objectives were to characterize the participant experience during device use, and present preliminary dynamic MRI data to demonstrate the different device capabilities. MATERIAL AND METHODS: Self-reported outcomes were used to characterize the pain, physical exertion and discomfort levels experienced by 10 healthy male participants during four different active knee motion and loading protocols using the novel device. Knee angular data were recorded during the protocols to determine the maximum knee range of motion achievable. Dynamic MRI was acquired for three healthy volunteers during passive, unloaded knee motion using 2D Cartesian TSE, 2D radial GRE and 3D UTE sequences; and during active, unloaded and loaded knee motion using 2D radial GRE imaging. Because of the different MRI sequences used, spatial resolution was inherently lower for active knee motion than for passive motion acquisitions. RESULTS: Depending on the protocol, some participants reported slight pain, mild discomfort and varying levels of physical exertion. On average, participants achieved ∼40° of knee flexion; loaded conditions can create knee moments up to 27Nm. High quality imaging data were obtained during different motion and loading conditions. Dynamic 3D data allowed to retrospectively extract arbitrarily oriented slices. CONCLUSION: A novel multipurpose device for guided, physiologically relevant knee motion and loading during dynamic MRI was developed. Device use was well tolerated and suitable for acquiring high quality images during different motion and loading conditions. Different bone positions between loaded and unloaded conditions were likely due to out-of-plane motion, particularly because image registration was not performed. Ultimately, this device could be used to advance our understanding of physiological and pathological joint mechanics.


Assuntos
Imageamento Tridimensional , Articulação do Joelho , Humanos , Masculino , Imageamento Tridimensional/métodos , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Imageamento por Ressonância Magnética/métodos , Dor
4.
J Bone Joint Surg Am ; 103(2): 146-154, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33060427

RESUMO

BACKGROUND: The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. METHODS: This retrospective study included 20 patients: 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. All patients completed the Knee Society Score, Forgotten Joint Score, and High-Flexion Knee Score questionnaires preoperatively and postoperatively. RESULTS: The BCS cohort showed greater femoral lateral rollback as well as a medial pivot in both activities. In contrast, the CR cohort showed a significant increase in anterior translation on the medial compartment as well as almost absent femoral lateral rollback. Higher clinical scores were observed in the BCS cohort. CONCLUSIONS: At 24 months postsurgery, despite equal bearing geometry, retention of the posterior cruciate ligament in the CR cohort apparently was insufficient to reduce anterior shift. The BCS cohort showed expected knee joint kinematics; however, the kinematics in this cohort could eventually benefit from a smooth transition between the interchanging surfaces. Further investigation should be focused on the surgical technique and its interaction with the TKA design. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/métodos , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Feminino , Humanos , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos
5.
Sci Rep ; 10(1): 759, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31937883

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

6.
Sci Rep ; 9(1): 9148, 2019 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-31235890

RESUMO

The knee joint center of rotation is altered in the absence of the anterior cruciate ligament, which leads to substantially higher variance in kinematic patterns. To overcome this, total knee arthroplasty (TKA) designs with a high congruency in the lateral compartment have been proposed. The purpose of this study was to analyze the influence of a lateral pivot TKA-design on in-vivo knee joint kinematics. Tibiofemoral motion was retrospectively addressed in 10 patients during unloaded flexion-extension and loaded lunge using single plane fluoroscopy. During the unloaded flexion-extension movement, the lateral condyle remained almost stationary with little rollback at maximum flexion. The medial condyle exhibited anterior translation during the whole flexion cycle. During the loaded lunge movement, a higher degree of rollback compared to the unloaded activity was observed on the lateral condyle, whereas the medial condyle remained almost stationary. The results showed a clear lateral pivot during the unloaded activity, reflective of the implant's geometric characteristics, and a change to a medial pivot and a higher lateral rollback during the weight-bearing conditions, revealing the impact of load and muscle force. It remains unclear if the kinematics with a lateral TKA design could be considered as physiological, due to the limited knowledge available on native knee joint kinematics.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...