Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inhal Toxicol ; 32(13-14): 447-455, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33140978

RESUMO

INTRODUCTION: Electronic cigarettes (e-cigarettes) have rapidly evolved since their introduction to the U.S. market. The rebuildable atomizer (RBA) offers user-driven modification to the heating element (coil) and wicking systems. Different coil materials can be chosen based on user needs and preferences. However, the heating element of an e-cigarette is believed to be one-source for toxic metal exposure. METHODS: E-cigarette coils from Kanthal and nichrome wires were constructed in a contact and non-contact configuration and heated at four voltages. The maximum temperatures of the coils were measured by infrared temperature sensing when dry and when saturated with 100% vegetable glycerin or 100% propylene glycol. The metal composition of each coil was analyzed with Scanning Electron Microscopy-Energy-Dispersive X-Ray (SEM-EDX) when new, and subsequently after 1, 50, and 150 heat cycles when dry. RESULTS: The coils reached temperatures above 1000 °C when dry, but were below 300 °C in both liquid-saturated mediums. Metal analysis showed a decrease of 9-19% chromium and 39-58% iron in Kanthal wire and a decrease of 12-14% iron and 39-43% nickel in nichrome wire after 150 heat cycles. Significant metal loss was observed after one heat cycle for both coil alloys and configurations. CONCLUSIONS: The loss of metals from these heat cycles further suggests that the metals from the coils are potentially entering the aerosol of the e-cigarette, which can be inhaled by the user.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Metais Pesados/análise , Raios Infravermelhos , Microscopia Eletrônica de Varredura , Temperatura , Raios X
2.
J Anal Toxicol ; 43(8): 592-599, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31504663

RESUMO

The use of electronic cigarettes (e-cigs) has expanded from a nicotine delivery system to a general drug delivery system. The internet is rife with websites, blogs and forums informing users how to modify e-cigs to deliver illicit drugs while maintaining optimal drug delivery of their device. The goal of this study was to qualitatively identify the presence of methamphetamine in the aerosol produced by an e-cig and to quantitatively assess the effect voltage on the concentration of aerosolized methamphetamine. A KangerTech AeroTank electronic cigarette containing a 30, 60 or 120 mg/mL of methamphetamine in 50:50 propylene glycol: vegetable glycerin formulation was used to produce the aerosol. To qualitatively identify aerosolized methamphetamine, the aerosol was generated at 4.3 V, trapped in a simple glass trapping system, extracted using solid-phase microextraction (SPME), and analyzed by high-resolution Direct Analysis in Real Time AccuTOF™ Mass Spectrometry (DART-MS). To assess the effect of voltage on the concentration of aerosolized methamphetamine, the aerosol was generated at 3.9, 4.3 and 4.7 V, trapped and quantified using gas chromatography mass spectrometry (GC/MS). SPME-DART-MS and SPME-GC-MS demonstrated the aerosolization of methamphetamine. The concentration of aerosolized methamphetamine at 3.9, 4.3 and 4.7 V was not statistically different at 800 ± 600 ng/mL, 800 ± 600 ng/mL and 1,000 ± 800 ng/mL, respectively. The characterization of the vapors produced from e-liquids containing methamphetamine provides an understanding of the dose delivery dynamics of e-cigarettes.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Sistemas Eletrônicos de Liberação de Nicotina/normas , Metanfetamina/análise , Nicotina/análise , Aerossóis , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Sólida
3.
Forensic Sci Int ; 271: 92-97, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28076838

RESUMO

MDMB-FUBINACA (aka MDMB(N)-Bz-F), chemical name Methyl (S)-2-(1-(4-fluorobenzyl)-1H-indazole-3-carboxamido)-3,3-dimethylbutanoate, a designer drug or a new psychoactive substance (NPS), was identified in three commercially available e-liquids formulated for electronic cigarette use. The e-liquids were evaluated using direct analysis in real time ion source attached to a time of flight mass spectrometer (DART-MS) and gas chromatograph mass spectrometer (GC-MS) to identify active ingredients/drugs, flavorants, and other possible constituents. The e-liquids were also evaluated for alcohol content by headspace gas chromatography with flame ionization detector (HS-GC-FID). The aerosol produced from the e-liquids by use of an e-cigarette was analyzed by solid phase micro-extraction gas chromatography mass spectrometry (SPME-GC-MS) to ensure delivery of the active ingredient/drug. Propylene glycol, vegetable glycerin, MDMB-FUBINACA, alcohol content and a flavor profile were determined for each of the e-liquids. MDMB-FUBINACA was determined to be the major active ingredient in all three e-liquids and was successfully detected by SPME-GC-MS in the aerosol generated by a KangerTech Aerotank clearomizer/electronic cigarette.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...